INVERTER SPLIT TYPE AIR CONDITIONER (50Hz) DUCT type Models Indoor unit Outdoor unit ARYA12LALU AOYB12LACL ARYA14LALU AOYB14LACL ARYA18LALU AOYB18LACL CONTENTS SPECIFICATIONS ....1 DIMENSIONS .
INDOOR UNIT ARYA12LALU ARYA14LALU ARYA18LALU OUTDOOR UNIT AOYB12LACL AOYB14LACL AOYB18LACL NOISE LEVEL High speed 32 dB 33 dB 33 dB Med speed 30 dB 31 dB 31 dB INDOOR UNIT Low speed 28 dB 29 dB 29 dB Quiet 26 dB...
Page 4
DIMENSIONS INDOOR UNIT (Unit : mm) 2007.11.08...
Page 5
OUTDOOR UNIT Unit : mm Top view Front view Side view Air flow 4- 10mm hole Drain pipe Bottom view mounting place ( 20) 2007.11.08...
CIRCUIT DIAGRAM REACTOR INDOOR UNIT OUTDOOR UNIT GRAY COMPRESSOR TERMISTOR GRAY ( PIPE TEMP. ) R (R) WHITE BLACK TERMISTOR BLACK ( ROOM TEMP. ) WHITE WHITE THERMISTOR BLACK S (S) 1 2 1 2 1 2 BLACK ( PIPE TEMP. ) C (T) BLACK CN5 CN7 CN8...
ERROR CONTENTS REMOTE CONTROL Code Error contents Troubleshooting at the remote control LCD This is possible only on the wired remote control. Indoor signal error Wired remote controller abnormal SELF-DIAGNOSIS Indoor room temperature sensor error If an error occurs, the following display will be Indoor heat exchanger temperature sensor (middle) error shown.
Page 14
OUTDOOR UNIT Error contents Thermistor malfunction on 0.1 sec / off 0.1 sec Abnormal discharge temperature Current surge protection on 0.5 sec / off 0.5 sec CT abnormality on 2.0 sec / off 2.0 sec Compressor position detection malfunction on 0.1 sec / off 2.0 sec Fan malfunction on 5.0 sec / off 5.0 sec PAM voltage abnormality...
PARTS INDOOR UNIT Part number Ref. Description ARYA14LALU ARYA12LALU ARYA18LALU 1 Air Filter 9366833017 9366833017 2 Side Panel R Sub Assy 9364505022 9364505022 3 Side Panel L Sub Assy 9364506029 9364506029 4 Front Panel Sub Assy 9364508023 9364508023 5 Evaporator Assy...
Page 16
INDOOR UNIT Ref. Description Part number Top Panel Sub Assy 9364507026 Panel Assy (Motor) 9363401004 Casing Assy 9363322002 Sirocco Fan Assy 9385258006 Motor Fixing Table Assy 9358591000 Fan Motor Assy 9602401017 Motor Fixture 9358594001 Rubber (Vibration-proof) 9385102002 Room Thermistor 9703299018 2007.11.08...
Page 17
INDOOR UNIT Ref. Description Part number Control Box 9375240035 Controller PCB Assy (12) 9707393170 Controller PCB Assy (14) 9707393187 Controller PCB Assy (18) 9707393057 Power Supply PCB Assy 9707398038 Terminal 9703345012 Terminal 9306489045 Remote Control 9372266199 Wire 9372714010 Hole Cover 9378176010 2007.11.08...
PARTS OUTDOOR UNIT Ref. Description Part number Top Panel Assy 9309230057 Cover (Switch) Assy 9309237032 Cabinet Assy 9314809040 Blow Down Grille 9308884015 Cabinet Right Assy 9309236011 Fan Ring 9308885012 Grip 9308880017 Emblem 9315210012 Protective Net 9315319012 2007.11.08...
Page 19
OUTDOOR UNIT Ref. Description Part number 4-Way Valve 9900047016 Pulse Motor Valve Assy 9311641018 Condenser Assy 9311382027 Thermistor Spring-A 313728262708 Thermistor Spring 9300089012 Propeller Fan 9309909014 9304902003 Motor Bracket 9308872012 Separator Assy 9312971015 Base Assy 9308869081 3-Way Valve Assy 9315159014 2-Way Valve Assy 9313064013 Expansion Valve Coil...
Page 20
OUTDOOR UNIT Ref. Description Part number Inverter PCB Assy (12) 9707427134 Inverter PCB Assy (14) 9707427141 Inverter PCB Assy (18) 9707427110 Fuse Holder 0501454012 Fuse Holder 0501456016 Fuse 0600382018 Fuse 0600372163 Terminal 9703874031 Inverter Case Assy 9315690012 2007.11.08...
STA N D A R D A C C ESSOR IES INDOOR UNIT Name and Shape Q’ty Application Name and Shape Q’ty Application Installation For positioning the Coupler heat For indoor side pipe template indoor unit insulation joint (gas pipe) (P/N 9364225005) (large) (P/N 9350716029)