Page 1
HPE Edgeline EL1000 System User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
Contents Component identification...............6 PCIe configuration........................6 Front panel components....................6 Front panel LEDs and buttons................... 6 Right side components.......................7 System board components....................8 PXI/PXIe configuration........................8 Front panel components....................8 Front panel LEDs and buttons................... 9 Right side components.....................10 System board components....................10 DIP switch......................11 Hot-plug drive LED definitions.....................11 Operations.....................
Page 4
Active Health System data collection..............38 Active Health System log..................38 iLO RESTful API support....................38 Integrated Management Log.................... 39 HPE Edgeline Component Pack....................39 HP Smart Update Manager....................39 UEFI System Utilities........................39 Using UEFI System Utilities..................... 40 Flexible boot control......................40 Restoring and customizing configuration settings............41 Secure Boot configuration....................41...
Component identification PCIe configuration Front panel components Item Description iLO port Network port 1 Network port 2 USB 3.0 ports Drives Cartridge Network connections are available in 1G and 10G. The 1G is shown. Front panel LEDs and buttons Item Description Status iLO and network port link...
Item Description Status Cartridge UID LED/button • Blue = Cartridge ID is selected • Flashing Blue = Cartridge firmware update is in progress or iLO IRC is in use • Off = Cartridge ID is not selected Cartridge health LED •...
System board components Item Description Fan 1 Fan 2 Fan 3 Power distribution board System battery PXI/PXIe configuration Front panel components Item Description iLO port Network port 1 Network port 2 Table Continued System board components...
Item Description USB 3.0 ports (4) Drives (2) Cartridge PXI/PXIe slot 3 PXI/PXIe slot 2 Network connections are available in 1G and 10G. The 1G is shown. Front panel LEDs and buttons Item Description Status iLO and network port link •...
Right side components Item Description Antenna connector Antenna connector Antenna connector Antenna connector REF in connector REF out connector Antenna connector Power supply System board components Item Description Fan 1 Fan 2 Table Continued Right side components...
Item Description Fan 3 DIP Switch Power distribution board System battery The fan cage might have to be removed to access the switch DIP switch Position Default Function • Off = Fan normal mode • On = Fan high mode Hot-plug drive LED definitions When a drive is configured as part of a SmartArray and connected to a powered-up controller, the drive LEDs indicate the condition of the drive.
Page 12
Drive Solid green The drive is a member of one or more logical drives. status Flashing The drive is rebuilding or performing a RAID migration, strip size green migration, capacity expansion, or logical drive extension, or is erasing. Flashing The drive is a member of one or more logical drives and predicts amber/ the drive will fail.
Operations This chapter describes the hardware operations carried out prior to and after installing or removing a hardware option, or performing a server maintenance or troubleshooting procedure. Before performing these hardware operations, review and observe the server warnings and cautions. Install an AC power supply Procedure 1.
Page 14
Remove the black connector from the rear of the power supply. Loosen the screws on the connector. Operations...
Page 15
Attach the (earthed) cable to the ground screw and washer and tighten to 13 lb-in of torque. The ground cable must be connected before connecting the -48V wire and return wire. Insert the -48V wire into the left side of the connector and tighten the screw to 10 lb-in of torque. Insert the return wire into the right side of the connector and tighten the screw to 10 lb-in of torque.
Page 16
Insert the power supply into the power supply bay until it clicks into place. Insert the connector into the power supply. Operations...
10. Attach the cables to the power supply handle with the hook-and-loop strap. 11. Route the power cord. Use best practices when routing power cords and other cables. A cable management arm is available to help with routing. To obtain a cable management arm, contact a Hewlett Packard Enterprise authorized reseller.
Procedure • Use one of the following methods to power down the system: ◦ Press and release the Power On/Standby button of the cartridges installed in the system. This method initiates a controlled shutdown of applications and the OS before the system enters standby mode.
Procedure 1. Remove the four T-15 Torx screws securing the wall mounting plate to the bottom of the system. 2. Disconnect all cables. Dismounting the system from a rack mount Procedure 1. Loosen the 2 captive screws on the front of rack mount shelf. 2.
Installing the fans Procedure 1. Align the fan with the fan slots of the system. 2. Squeeze the tabs on either side of the fan, and then slide it into the bay until it clicks in place. Installing the cartridge About this task No cartridges supported on the system support Legacy BIOS Boot mode.
Install the mini-PCIe adapter board Procedure 1. Align the mini-PCIe adapter board to the system board. 2. Using a Torx driver, insert and tighten the three T-15 Torx screws to secure the adapter board to the system board. 3. Connect the two cables from the mini-PCIe adapter board to the system board: a.
Setup This chapter describes the initial setup procedures to prepare the server for operation. Optional services Hewlett Packard Enterprise offers the HPE Foundation Care Next Business Day Exchange Service for this product. HPE Foundation Care Next Business Day Exchange Service provides a replacement product or part delivered free of freight charges to your location the next business day after a call is opened and provides support 24 hours per day, Monday through Sunday.
Installing hardware options Install any hardware options before initializing the system. For options installation information, see the option documentation. For system-specific information, see "Hardware options installation." Registering the product To experience quicker service and more efficient support, register the product at the Hewlett Packard Enterprise Product Registration website.
Hardware options installation Installing the wall mounting option kit Procedure 1. Using the wall mount bracket, mark the locations for the wall mount screws. 2. Install the wall mount anchors and screws in the marked locations. 3. Align the wall mount bracket to the system. 4.
3. Install the system in the rack mount. Installing the ETSI rack mounting option kit Procedure 1. Align the rack mount bracket to the system. 2. Using a Torx driver, insert and tighten four T-10 Torx screws to secure the bracket to the system. 3.
Instructions that ships with the rack hardware kit. 2. Install the cable management arm. For more information on installing the cable management arm, see the HP 1U Cable Management Arm Option Installation Instructions that ships with the cable management arm kit.
Page 27
5. Align and install the system. 6. Install the retention bracket. Hardware options installation...
Installing the drive Procedure 1. Align the drive to the drive bay, and slide it into the bay until it clicks in place. 2. Close the locking latch to secure the drive. Installing the card options Depending on the configuration of your system, perform one of the following procedures: •...
Page 29
IMPORTANT: The PCIe card is not hot-pluggable. The system must be powered down to install this card. Procedure 1. Remove power from the system. 2. If installed, remove the cartridge. 3. Remove the access panel. 4. Using a Torx driver, remove the three black T-15 Torx screws. 5.
Install the PXI/PXIe card About this task The system supports optional PXI cards. NOTE: The PXI/PXIe card is not hot-pluggable. The system must be powered down to install this card. Procedure 1. Power down the system. 2. Remove the PXI/PXIe blank screws, and then remove the blank. 3.
Installing the mini-PCIe module options You can install the following mini-PCIe modules on the mini-PCIe adapter board: • Up to two half-length mini-PCIe modules • Up to two full-length mini-PCIe modules Install a half-length mini-PCIe module option About this task You will need a half-length mini-PCIe module adapter provided with the WiFi option kit to install this option.
Installing a full-length mini-PCIe module Procedure 1. Align the full-length mini-PCIe module with the full-length slot on the mini-PCIe adapter board. 2. Insert the mini-PCIe module connector into the slot. 3. Using a Phillips screwdriver, insert and tighten the two screws to secure the mini-PCIe module to the board.
Configuration Accessing the System Utilities menu About this task To complete these steps, you need the HPE USB-to-serial cable (HPE part number 871947-B21). Table 1: Settings for connecting USB cable to serial port Specifications Value Baud rate 115200 Data bits Parity None Stop bit...
Viewing or updating the DHCP address using the serial console cable Procedure 1. Access the System Utilities menu. 2. Navigate through the menu options System Configuration > iLO 4 Configuration Utility > Network > DNS/DHCP, and press Enter. The Network Autoconfiguration screen displays. 3.
Setting the static IP address using the serial console cable Procedure 1. Access the System Utilities menu. 2. Navigate through the menu options System Configuration > iLO 4 Configuration Utility > Network Options. The Network Options screen displays. 3. Change DHCP Enable to OFF. 4.
Page 36
5. Once completed, press ESC to back out of the menus. Save the settings when prompted. 6. After saving all settings, iLO prompts for a reset in order for the new settings to be used. Reset the system. Configuration...
Software and configuration utilities Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website. Supported operating systems and drivers matrix To validate the minimum supported Operating System for a system platform, go to the Hewlett Packard Enterprise website: http://www.hpe.com/info/ossupport To download the latest device drivers, go to the Hewlett Packard Enterprise Support Center website:...
The data that is collected is managed according to the Hewlett Packard Enterprise Data Privacy policy. For more information, see the Hewlett Packard Enterprise website. The Active Health System, in conjunction with the system monitoring provided by Agentless Management or SNMP Pass-thru, provides continuous monitoring of hardware and configuration changes, system status, and service alerts for various server components.
The version of HP SUM included with each HPE Edgeline Component Pack release is designed to be the best solution for installing Edgeline System firmware updates. Always use the included version of HP SUM for Edgeline System updates.
Using UEFI System Utilities To use the System Utilities, use the following keys. Action Access System Utilities F9 during server POST Navigate menus Up and Down arrows Select items Enter Save selections Access Help for a highlighted configuration option Scan the QR code on the screen to access online help for the UEFI System Utilities and UEFI Shell.
Restoring and customizing configuration settings You can reset all configuration settings to the factory default settings, or you can restore and use the system default configuration settings. You can also configure default settings as necessary, and then save the configuration as the custom default configuration.
For more information on the Embedded Diagnostics option, see the UEFI System Utilities user guide for your system on the Hewlett Packard Enterprise website. iLO RESTful API support for UEFI The ProLiant Gen9 servers include support for a UEFI-compliant System BIOS, along with UEFI System Utilities and Embedded UEFI Shell preboot environments.
Troubleshooting HPE Edgeline Troubleshooting Guide The HPE Edgeline System Troubleshooting Guide provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification, issue resolution, and software maintenance on the Edgeline System. The document is available in the Hewlett Packard Enterprise Information Library.
Battery Battery specifications Feature Specification Type Maintenance-free, sealed, CR2032 lithium manganese dioxide button battery Voltage 3.0 V Replace the system battery Procedure 1. Locate the battery on the system board: • PCIe configuration system board • PXIe configuration system board 2.
Page 45
For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. Battery...
Warranty and regulatory information Warranty information HPE ProLiant and x86 Servers and Options HPE Enterprise Servers HPE Storage Products HPE Networking Products Regulatory information Safety and regulatory compliance For important safety, environmental, and regulatory information, see Safety and Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at the Hewlett Packard Enterprise website (http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts).
• Kazakhstan: Manufacturing date: The manufacturing date is defined by the serial number. CCSYWWZZZZ (serial number format for this product) Valid date formats include: • YWW, where Y indicates the year counting from within each new decade, with 2000 as the starting point;...
Electrostatic discharge Preventing electrostatic discharge About this task To prevent damaging the system, be aware of the precautions you must follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
Specifications Product QuickSpecs For more information about product features, specifications, options, configurations, and compatibility, see the product QuickSpecs on the Hewlett Packard Enterprise website. Environmental specifications Table 2: Standard specifications Specification Value Temperature range — Operating 10°C to 35°C (50°F to 95°F) Nonoperating -30°C to 60°C (-22°F to 140°F) Relative humidity (noncondensing)
Page 50
Table 4: ASHRAE Class A4 specifications Specification Value Temperature range — Operating 5°C to 45°C (41°F to 113°F) Nonoperating -30°C to 60°C (-22°F to 140°F) — Relative humidity (noncondensing) Operating 8% to 90% at 28°C (82.4°F) maximum wet bulb temperature Non-Operating 5% to 95% at 38.7°C (101.7°F) maximum wet bulb temperature...
Environmental specifications-system components support matrix Environment Support status Base Fans SFF drives SATA M.2 NVME M.2 PCIe I/O PXIe I/O specification system drives drives cards cards Standard Yes (with Yes (up to Operating redundanc 38 W) Support Extended Yes (with Yes (up to Ambient 40°C redundanc...
Page 52
HPE 500W Flex Slot Platinum Hot Plug Power Supply Input voltage range (V rms) 100-24 Frequency range (Nominal) (Hz) 50-60 Nominal input voltage (V rms) Maximum rated output wattage rating (Watts) Nominal input current (A rms) Maximum rated input wattage rating (Watts) Maximum rated VA (Volt-Amp) Efficiency (%)
PXI/PXIe specifications NOTE: Specifications are subject to change without notice. Electrical load regulation specifications Voltage (V) Load regulation (%) +3.3 <5 <5 <5 <5 Chassis cooling specifications Specification Value Module cooling system Forced air circulation (positive pressurization) through three fans with High/Auto speed selector. Launch Recipe supports this.
Page 54
Component Quantity Specification SATA M.2/cartridge 64 GB NVME M.2/cartridge PXI 6341 800 W AC Table 7: Base configuration 2 (m710x) Component Quantity Specification Cartridge m710x DIMMs/cartridge SATA M.2/cartridge 64 GB NVME M.2/cartridge PXI 6341 800 W AC The LWAd and LpAm when the system is operating in a 23°C ambient environment are provided in the following tables.
HPE EMC compliance testing Emissions classification FCC rating Class A Normative standards • CISPR 22 • EN55022 • EN55024 • FCC CFR 47 • Pt 15 • ICES-003 • CNS13438 • • • EN 61000-3-2 • EN 61000-3-3 • EN 60950-1 •...
Page 56
Specification Value Maximum jitter 5 ps RMS phase jitter (10 Hz to 12 kHz range); 5 ps RMS phase jitter (12 kHz to 20 MHz range) Duty factor for PXIe_CLK100 45% to 55% Absolute single-ended voltage swing (when each 400 mV to 1,000 mV line in the differential pair has 50 W termination to 1.30 V or Thévenin equivalent) NOTE:...
• Software Depot • Customer Self Repair • Insight Remote Support • Serviceguard Solutions for HP-UX • Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix • Storage white papers and analyst reports Accessing Hewlett Packard Enterprise Support • For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website: http://www.hpe.com/assistance...
Accessing updates • Some software products provide a mechanism for accessing software updates through the product interface. Review your product documentation to identify the recommended software update method. • To download product updates: Hewlett Packard Enterprise Support Center www.hpe.com/support/hpesc Hewlett Packard Enterprise Support Center: Software downloads www.hpe.com/support/downloads Software Depot www.hpe.com/support/softwaredepot...
Page 59
HPE Proactive Care advanced service: Supported products list www.hpe.com/services/proactivecareadvancedsupportedproducts Proactive Care customer information Proactive Care central www.hpe.com/services/proactivecarecentral Proactive Care service activation www.hpe.com/services/proactivecarecentralgetstarted Support and other resources...
Documentation feedback Hewlett Packard Enterprise is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hpe.com). When submitting your feedback, include the document title, part number, edition, and publication date located on the front cover of the document.