GE Contactless Smart Card Reader Model 240 and 245 Installation Guide 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487 (561) 998-6100 Part Number: 460563001B January 2003...
Page 3
Copyright 2003 GE Interlogix, CASI All rights reserved. Printed in the U.S.A The Model 240 and 245 Smart Card Readers are trademarks of GE Interlogix-CASI Division. ® MIFARE is a registered trademark of Philips Electronics, N.V.
FIGURE 3: GE Model 24x Reader Backplate (includes tamper switch magnet) Note: Mounting holes fit standard US single-width electrical box and standard European (EMEA) electrical box hole patterns. An Isolation Spacer (shown in Figure 4) may be used to improve the read- range distance when mounting to metal surfaces.
Secure Perfect Edition Setup The Secure Perfect Edition access control system supports Badge IDs (BIDs) up to a maximum of 12-digits. Since the Model 24x readers output a 16-digit BID number, the Secure Perfect host controller/ GE Contactless Smart Card Reader Model 24x...
Page 11
BID numbers, and convert them into the proper 12-digit BID format. To make a Secure Perfect 4.0 or higher system compatible with the complete line of GE Contactless Smart Card Reader, do the following: • Install Secure Perfect Edition, 4.0 or higher •...
Installation Considerations Installation of the GE Model 24x Reader on metal. Read-range reduction can be improved by adding Isolation Spacers (approximately 25% per plate). Installation of two Model 24x Smart Card Readers side-by-side. Read range is not affected if the center-to-center distance between two readers is equal to or greater than four inches (101.60 mm).
• Micro/5 Controller with either 2RP or 8RP Reader Boards: refer to the Micro/5 Installation Guide. IMPORTANT: DO NOT use the GE Model 24x Readers with the Micro/5 2SRP. • Micro/PX-2000 and Micro/PXN-2000 controllers: refer to the Micro/ PX-2000 and Micro/PXN-2000 Installation Guide.
8 VDC to 30 VDC Door contact Reader Data 1 Exit request (REX) Green LED Micro control, red LED (option) RS-485-B, reader firmware maintenance RS-485-A, reader firmware maintenance Reserved for future use Reserved for future use GE Contactless Smart Card Reader Model 24x...
Page 16
12. Connect protection diode across relay coil. Connect a diode across the relay coil (cathode to positive side of relay coil). General note: Pair wires as shown in all wiring diagrams. GE Contactless Smart Card Reader Model 24x...
FIGURE 8: Model 24x Smart Card Reader Wiring Diagram to J-Box GE Contactless Smart Card Reader Model 24x...
Page 20
Table 4: 2RP Reader Board Address Settings SW 1 SW 2 Reader Board Note: Switches SW2-5, 6, 7, and 8 are not used. Jumper W1 RN2 and RN5 (labeling) Use 2k Ω (202) resistor packs. Set to 12 V GE Contactless Smart Card Reader Model 24x...
Page 22
Readers 9 - 16 Note: the 8RP board appears to the Micro as four 2RP boards. SW 2 Board Type Standard Board 1 Board 2 a. Readers 1 - 8. b. Readers 9 -16. GE Contactless Smart Card Reader Model 24x...
FIGURE 11: GE Model 24x Reader to Micro If using a J-Box relay as a dry contact, place a jumper across J4, pins 1 and 2 as shown in Figure 11 above. Connect the power supply in series with the door strike.
LED does not light when an Verify that the access card has been entered and ISO 15963 or that the reader has been properly configured in ISO 14443A card the host system. is presented. GE Contactless Smart Card Reader Model 24x...
Page 25
If none of the above steps have identified the problem, there may be a significant noise source present in the installation which is interfering with the reader-to-microcontroller communications. If this is the case, use shielded wire for reader-to- microcontroller connections. GE Contactless Smart Card Reader Model 24x...
Page 26
5 seconds and the red LED reader connector. also flashes A 470 Ω ½-watt pull-up resistor is required every 5 seconds. between 12 VDC and Reader Data 1 on the Micro/ 5 2RP (only). GE Contactless Smart Card Reader Model 24x...
Regulatory Notices Changes or modifications not expressly approved by GE-Interlogix for compliance could void the user’s authority to operate the equipment. FCC and CE Compliance. Shield grounds must be stripped back through the knockout hole (strain relief) and grounded to the external ground stud provided on the microcontroller.
Page 29
Boca Raton, FL USA 33487 EU Representative: Interlogix Europe & Africa Excelsiorlaan 28 B- 1930 Zaventum Belgium Product Product: GE Interlogix, CASI Smart Card Reader Identification: Model Number: 240, 245 Brand: CASI Means of Conformity: • Hereby, GE Interlogix, CASI, declares that this...
Page 30
GE Contactless Smart Card Reader Model 24x...
Page 31
GE Contactless Smart Card Reader Model 24x...
Page 32
GE Contactless Smart Card Reader Model 24x...
Page 33