Finishing - Fujitsu ASYG36LMTA Installation Manual

Wall mounted type
Hide thumbs Also See for ASYG36LMTA:
Table of Contents

Advertisement

(2) R emove the tapping screw and while minding the cable clamp hook, remove the cable
clamp.
Screw
Cable clamp
(3) C onnect the end of the connection cable fully into the terminal block.
Earth (ground) wire
7.3. How to connect wiring to the terminals
Caution when wiring cable
To strip off the insulation of a lead wire, always use a special tool such as a wire stripper.
If there is no special tool, carefully strip off the insulation by using a knife or other utensil.
(1) Use ring terminals with insulating sleeves as shown in the figure to connect to the
terminal block.
(2) Securely clamp the ring terminals to the wires by using an appropriate tool so that the
wires do not come loose.
Strip : 10 mm
(3) Connect specified wires securely, and fasten them so that there is no stress applied on
the terminals.
(4) Use a screwdriver with an appropriate bit size to tighten the terminal screws. Using of
screwdriver with inappropriate bit size will damage the screw heads, and the screws
will not be tightened properly.
(5) Do not overtighten the terminal screws. Otherwise, the screws may break.
Screw with special washer
Ring terminal
Wire
Terminal blocks
(6) See the table for the terminal screw tightening torques.
Tightening torque [N·m (kgf·cm)]
M4 screw
En-6
AMP Air Conditioning
Hook
Cable clamp
1 2 3
Ring terminal
Sleeve
Screw with special washer
Ring terminal
Wire
1.2 to 1.8 (12 to 18)
• M atch the terminal block numbers and connection cable colors with those of the
outdoor unit. Incorrect wiring may cause a fire.
• C onnect the connection cables firmly to the terminal block. Imperfect installation may
cause a fire.
• W hen fixing the connection cable with the cable clamp, always fasten the cable at the
plastic jacket portion, but not at the insulator portion. If the insulator is chafed, electric
leakage may occur.
• A lways connect the earth (ground) wire. Improper earthing (grounding) work can
cause electric shocks.
• D o not use the earth (ground) screw for the indoor unit to the outdoor unit unless it is
specified.

8. FINISHING

(1) Insulate between pipes.
• Insulate suction and discharge pipes separately.
• For rear, right, and bottom piping, overlap the connection pipe heat insulation and
indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap.
(2) Temporarily fasten the connection cable along the connection pipe with vinyl tape.
(Wrap to about 1/3 the width of the tape from the bottom of the pipe so that water
does not enter.)
(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with sealer so that rain
water and wind cannot blow in.
(5) Fasten the drain hose to the outside wall, etc.
Saddle*
Pipe
Overlap the insulation
Connection pipe
(heat insulation)
Bind the pipes together
so that there is no gap.
Pipe
Drain hose
Drain hose insulation is used
when the diameter of gas pipe is
Ø12.70 or more.
Butt connection pipe (heat
insulation) against the indoor
unit pipe (heat insulation) and
wrap with drain hose insula-
tion so that there is no gap.
Check the following:
GOOD
Drain hose
Saddle
www.ampair.co.uk | sales@ampair.co.uk
CAUTION
Outside wall cap*
Sealer putty*
(Outdoors)
Wall
*Locally purchased
Indoor unit pipe
(heat insulation)
Vinyl tape
Wrap with cloth tape
Cloth tape
PROHIBITED
Lifted up
Wave
End in water