NN-P795 NN-P794SFR 2 MEASUREMENTS AND ADJUSTMENTS 2.1. Adjustment of primary latch switch, secondary latch switch and short switch. 1. Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL.
NN-P795 NN-P794SFR 3 PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE 3.2.1. Measurement with the outer panel removed. Whenever you replace the magnetron, measure for radiation leakage before the outer panel is installed and after all necessary components are replaced or adjusted. Special care should be taken in measuring around the magnetron.
NN-P795 NN-P794SFR 4 SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOUTING Purpose: Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below. Procedure: Follow the matrix table below to identify the problem source.
NN-P795 NN-P794SFR 5.2. PARTS LIST NOTE: 1. When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part. 2. Important safety notice: Components identified by mark have special characteristics important for safety.