FEATURES MODEL ASTG09KMCA / AOTG09KMCA ASTG12KMCA / AOTG12KMCA FEATURES Energy efficiency MODEL ASTG09KMCA ASTG12KMCA Cooling STAR RATING INDEX Heating More comfortable airflow High efficient compact design Cross section of copper pipes...
Page 5
Energy saving control Human sensor catches movements of people in a room, and operates with lower capacity when the room is empty. When people come back to the room, it automatically returns to the previous operating mode. Energy saving operation by detecting someone’s movement Human sensor ...
WIRELESS REMOTE CONTROLLER FEATURES 5 mode timer setup available (ON / OFF / WEEKLY / PROGRAM / SLEEP). Easy operation. Easy to change signal code (max. 4 signal codes) by button operation. ...
SPECIFICATIONS WALL MOUNTED Type INVERTER HEAT PUMP Model name ASTG09KMCA ASTG12KMCA Power source 240 V ~ 50 Hz Available voltage range 198 V - 264 V Cooling Star rating index 10-star standard Heating 2.50 3.50 Rated Btu/h 8,500 11,900 Cooling 0.90 - 3.60...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Note: Fan speed : High Operation mode : FAN MODEL : ASTG09KMCA Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right &...
Page 15
Note: Fan speed : High Operation mode : FAN MODEL : ASTG12KMCA Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Center Unit : m/s TOP VIEW Vertical flap : Up Horizontal flap : Right & Left...
7-2. AIRFLOW MODEL : ASTG09KMCA Cooling Number of Fan speed rotations Airflow (r.p.m.) HIGH 1240 1050 QUIET Heating Number of Fan speed rotations Airflow (r.p.m.) HIGH 1240 1050 QUIET - (01 - 13) -...
Page 17
MODEL : ASTG12KMCA Cooling Number of Fan speed rotations Airflow (r.p.m.) HIGH 1280 1120 QUIET Heating Number of Fan speed rotations Airflow (r.p.m.) HIGH 1280 1120 QUIET - (01 - 14) -...
ELECTRICAL CHARACTERISTICS Model name ASTG09KMCA ASTG12KMCA Voltage 240 ~ Power supply Frequency Max. operating current Connection cable Wiring spec. Limited wiring length NOTES on Wiring spec.: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. • Limited wiring length: Limit voltage drop to less than 2 %. Increase cable gauge if voltage drop is 2 % or more.
SAFETY DEVICES Model Protection form ASTG09KMCA ASTG12KMCA Circuit protection Current fuse (PC board) 250 V 3.15 A OFF: 160 ± 25 °C Fan motor protection Thermal protector program ON: 110 ± 25 °C - (01 - 18) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CNA01 Control input See external CNB01 Operation status output input/output settings for details. CNB02 Error status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector DC 24 V Ex.) Relay unit Ex.) Display Relay power supply...
Page 24
ERROR STATUS OUTPUT An air conditioner error status signal can be output. Circuit diagram example Indoor unit control PC board Communication kit Connected unit Connector DC 24 V Ex.) Relay unit Ex.) Display Relay power supply 10 m* Signal Optional parts...
FUNCTION SETTINGS 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. •...
Page 26
FUNCTION DETAILS Functions 1) Filter sign 2) Room temperature control for cooling 3) Room temperature control for heating 4) Auto restart 5) Room temperature sensor switching 6) Remote controller signal code 7) External input control 8) Indoor unit fan control for energy saving for cooling 1) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.
Page 27
4) Auto restart Enable or disable automatic restart after a power interruption. ( ... Factory setting) Setting description Function number Setting value Enable Disable * Auto restart is an emergency function such as for power outage etc. Do not attempt to use this function in normal operation. Be sure to operate the unit by remote controller or external device.
Page 28
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal if the right signal code has not been set.) (1) Press the START/STOP ( / ) button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS 13-1. CONTROLLERS Exterior Parts name Model No. Summary Large and full-dot liquid crystal screen, wide and large keys Wired remote easy to press, user-intuitive UTY-RVNYN arrow key. controller *Optional communication kit is necessary for installation. The room temperature can be controlled by detecting the Wired remote temperature accurately with...
Page 30
2. OUTDOOR UNIT SINGLE TYPE: AOTG09KMCA AOTG12KMCA DTR_AO143E_01 2013.07.19...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOTG09KMCA AOTG12KMCA Power source 240 V ~ 50 Hz Available voltage range 198 V - 264 V Starting current Cooling 472 (1700) 539 (1940) Airflow rate Heating 428 (1540) 428 (1540) Type × Q'ty Propeller fan ×...
DIMENSIONS MODELS: AOTG09KMCA, AOTG12KMCA (Unit: mm) Top view Side view Front view Side view Airflow 4-ø11.3 mm hole Drain port (Ø20) Bottom view INSTALLATION PLACE (Unit: mm) 100 or more 100 or more 200 or more If the space is larger than stated, the condition will be the same as those without any obstacles.
ELECTRICAL CHARACTERISTICS Model name AOTG09KMCA AOTG12KMCA Voltage 240 ~ Power supply Frequency Max. operating current * Starting current Main fuse (Circuit breaker) current Wiring spec. * Power cable Use conformed cable with Type 60245 IEC 57. *1: The maximum current is the total current of indoor unit and outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
SAFETY DEVICES Model Protection form AOTG09KMCA AOTG12KMCA Current fuse ― ― (Near the terminal) Circuit protection 250 V 20 A Current fuse (Main PC board) 250 V 5 A OFF: 150 ± 15 °C Fan motor protection Thermal protection program ON: 120 ±...