hit counter code
Fujitsu ASYA09KLWA Design & Technical Manual

Fujitsu ASYA09KLWA Design & Technical Manual

Wall mounted type

Advertisement

AIR CONDITIONER
Wall mounted type
DESIGN & TECHNICAL MANUAL
INDOOR
OUTDOOR
ASYA09KLWA
ASYA12KLWA
AOYA09KLWA
AOYA12KLWA
DR_AS080EF_01
2018.06.29

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASYA09KLWA

  • Page 1 AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYA09KLWA ASYA12KLWA OUTDOOR AOYA09KLWA AOYA12KLWA DR_AS080EF_01 2018.06.29...
  • Page 2 Notices: • Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Copyright © 2018 Fujitsu General Limited. All rights reserved.
  • Page 3: Table Of Contents

    CONTENTS Part 1. INDOOR UNIT................1 1. Specifications....................2 2. Dimensions....................4 2-1. Models: ASYA09KLWA and ASYA12KLWA ..............4 3. Wiring diagrams ....................5 3-1. Models: ASYA09KLWA and ASYA12KLWA ..............5 4. Capacity table....................6 4-1. Cooling capacity.......................6 4-2. Heating capacity ......................7 5. Fan performance ...................8 5-1. Air velocity distributions....................8 5-2.
  • Page 4 CONTENTS (continued) Part 2. OUTDOOR UNIT..............19 1. Specifications....................20 2. Dimensions....................21 2-1. Models: AOYA09KLWA and AOYA12KLWA ..............21 3. Installation space ..................22 3-1. Models: AOYA09KLWA and AOYA12KLWA ..............22 4. Refrigerant circuit ..................24 4-1. Models: AOYA09KLWA and AOYA12KLWA ..............24 5. Wiring diagrams ..................25 5-1.
  • Page 5: Part 1. Indoor Unit

    Part 1. INDOOR UNIT WALL MOUNTED TYPE: ASYA09KLWA ASYA12KLWA...
  • Page 6: Specifications

    1. Specifications Wall mounted Type Inverter heat pump Model Name-indoor unit ASYA09KLWA ASYA12KLWA Power supply 1ɸ , 230V, 50Hz Avaliable range 198~264V 2.64 3.52 Rated Btu/h 9000 12000 Cooling 0.91-3.11 1.11-4.16 Min.-Max. Btu/h 3100-10600 3800-14200 Capacity 2.93 3.81 Rated Btu/h...
  • Page 7 805x194x285 Dimensions (H × W × D) Gross 870x285x360 Weight Gross Liquid φ6.35 (φ1/4) mm (in) φ9.52 (φ3/8) Connection pipe Gass Method Flare Material Drain hose Size φ16 °C 17-32 Cooling Operation range 80 or less Heating °C 0-30 Remote controller type Wireless Cooling Energy efficiency class...
  • Page 8: Dimensions

    2. Dimensions 2-1. Models: ASYA09KLWA and ASYA12KLWA Unit: mm ¢ Installation space requirement Provide sufficient installation space for product safety. Unit: mm 150 or more or more or more 2,300 or more - 4 - 2-1. Models: ASYA09KLWA and ASYA12KLWA...
  • Page 9: Wiring Diagrams

    3. Wiring diagrams 3-1. Models: ASYA09KLWA and ASYA12KLWA Abbreviation Paraphrase Ground Connection Positive and Negative Ion Generator Capacitor PLASMA Electronic Dust Collector LIVE NEUTRAL Heater The Electric Heating Belt of Indoor Unit Indoor Room Temperature Coil Temperature of Evaporator - 5 - 3-1.
  • Page 10: Capacity Table

    Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 4-1. Cooling capacity  Model: ASYA09KLWA  Model: ASYA12KLWA - 6 - 4-1. Cooling capacity...
  • Page 11: Heating Capacity

    4-2. Heating capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. ¢ Model: ASYA09KLWA ¢ Model: ASYA12KLWA - 7 - 4-2. Heating capacity 4. Capacity table...
  • Page 12: Fan Performance

    5. Fan performance 5-1. Air velocity distributions ¢ Model: ASYA09KLWA Fan speed Operation mode Measuring conditions HIGH Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left - 8 - 5-1.
  • Page 13 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Right Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center - 9 - 5-1. Air velocity distributions 5.
  • Page 14 ¢ Model: ASYA12KLWA Fan speed Operation mode Measuring conditions HIGH Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left - 10 - 5-1. Air velocity distributions 5.
  • Page 15 Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Right Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center - 11 - 5-1. Air velocity distributions 5.
  • Page 16: Airflow

    5-2. Airflow ¢ Model: ASYA09KLWA  Cooling/Heating Fan speed Airflow HIGH ¢ Model: ASYA12KLWA  Cooling/Heating Fan speed Airflow HIGH - 12 - 5-2. Airflow 5. Fan performance...
  • Page 17: Operation Noise (Sound Pressure)

    6. Operation noise (sound pressure) 6-1. Noise level curve ¢ Model: ASYA09KLWA •Cooling •Heating NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 1000 2000 4000 8000 1000 2000 4000 8000 Band Center Frequency /Hz Band Center Frequency /Hz ¢...
  • Page 18: Sound Level Check Point

    6-2. Sound level check point 0.8m Microphone Microphone NOTES: • Sound measured at 1 m away from the center of the unit. • Data is valid at free field condition. • Data is valid at nominal operation condition. • Reference acoustic pressure 0 dB=20 μPa. •...
  • Page 19: Safety Devices

    7. Safety devices Model Type of protection Protection form ASYA09KLWA ASYA12KLWA Circuit protection Current fuse (PCB*) 250 V, 20 A *PCB: Printed Circuit Board - 15 - 7. Safety devices...
  • Page 20: Remote Controller

    8. Remote controller 8-1. Wireless remote controller ¢ Overview SILENCE/FP ON/OFF Used to activate silence Turns the unit on or off. and 8 C heating feature. MODE Scrolls through operation TEMP modes as follows: Increases temperate in AUTO COOL C increments. HEAT Max.
  • Page 21 • UP Button ( ) and DOWN Button ( Increase or decrease set temperature. NOTE: Temperature control is not available in Fan mode. • SLEEP: Select this function during the sleeping time. It keeps the most comfortable temperature and save energy. This function is available in COOL, HEAT or AUTO mode only. NOTE: While the unit is running in sleep mode, it would be cancelled if MODE, FAN SPEED or ON/OFF button is pressed.
  • Page 22: Accessories

    1-9. Accessories Part name Exterior Q’ty Part name Exterior Q’ty SPL I T -TYPE ROOM AIR CONDITIONER SPLI T-TYPE ROOM AIR CONDITIONE R Installation Manual Owne r ’ s Manua l Forest Series Forest Series All Model Numbers All Model Numbers Owner’s manual Installation manual CS78421-548-754...
  • Page 23: Part 2. Outdoor Unit

    Part 2. OUTDOOR UNIT SINGLE TYPE: AOYA09KLWA AOYA12KLWA...
  • Page 24: Specifications

    1. Specifications Wall mounted Type Inverter heat pump Model Name-outdoor unit AOYA09KLWA AOYA12KLWA Power supply 220-240V, 1Ph, 50Hz Available voltage range 198-264V Airflow 1700 Type × Q’ty Propeller fan × 1 Output Sound pressure level HIGH dB (A) 57.5 Cooling Sound power level dB (A) Heating...
  • Page 25: Dimensions

    2. Dimensions 2-1. Models: AOYA09KLWA and AOYA12KLWA Unit: mm - 21 - 2-1. Models: AOYA09KLWA and AOYA12KLWA 2. Dimensions...
  • Page 26: Installation Space

    3. Installation space 3-1. Models: AOYA09KLWA and AOYA12KLWA ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
  • Page 27  Multiple outdoor unit installation L ≤ 1/2H 250 mm or more L ≤ H 1/2H ˂ L ≤ H 300 mm or more L ˃ H Can not be installed Do not install the rows of series like following figure. NOTES: •...
  • Page 28: Refrigerant Circuit

    4. Refrigerant circuit 4-1. Models: AOYA09KLWA and AOYA12KLWA Throttle device (Valve/Capilliary Tube) Liquid side 2-Way Valve Indoor Heat Outdoor Heat 4- Way Exchanger Exchanger Valve T1-Sensor Muffler T4-Sensor (Indoor) Muffler (Outdoor) T3-Sensor (Condensor) T5-Sensor(Discharge) T2-Sensor (Evaporator) Gas side 3-Way Valve Heating Cooling Compressor...
  • Page 29: Wiring Diagrams

    5. Wiring diagrams 5-1. Models: AOYA09KLWA and AOYA12KLWA Abbreviation Paraphrase 4-WAY 4-WAY VALVE AC-FAN Alternating Current FAN DC-FAN Direct Current FAN AC Current Detector COMP Compressor Coil Temperature of Condenser Outdoor Ambient Temperature Compressor Discharge Temperature Electronic Expansive Valve - 25 - 5-1.
  • Page 30: Capacity Compensation Rate For Pipe Length And Height Difference

    6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOYA09KLWA and AOYA12KLWA NOTE: Values mentioned in the table are calculated based on the maximum capacity.
  • Page 31: Additional Charge Calculation

    7. Additional charge calculation 7-1. Models: AOYA09KLWA and AOYA12KLWA Refrigerant type Refrigerant amount ¢ Refrigerant charge Total pipe length 5 or less 25 (Max.) 15 g/m Additional charge - 27 - 7-1. Models: AOYA09KLWA and AOYA12KLWA 7. Additional charge calculation...
  • Page 32: Airflow

    8. Airflow 8-1. Models: AOYA09KLWA and AOYA12KLWA  Cooling 1,700 1,001  Heating 1,700 1,001 - 28 - 8-1. Models: AOYA09KLWA and AOYA12KLWA 8. Airflow...
  • Page 33: Operation Noise (Sound Pressure)

    9. Operation noise (sound pressure) 9-1. Noise level curve ¢ Model: AOYA09KLWA •Cooling •Heating Heating Cooling NC-70 NC-70 NC-60 NC-60 NC-50 NC-50 NC-40 NC-40 NC-30 NC-30 1000 2000 4000 8000 1000 2000 4000 8000 Band Center Frequency /Hz Band Center Frequency /Hz ¢...
  • Page 34: Sound Level Check Point

    9-2. Sound level check point Outdoor unit Microphone NOTES: • H= 0.5 × height of outdoor unit. • Sound measured at 1 m away from the center of the unit. • Data is valid at free field condition. • Data is valid at nominal operation condition. •...
  • Page 35: Electrical Characteristics

    10. Electrical characteristics Model name AOYA09KLWA and AOYA12KLWA Voltage 230 ~ Power supply Frequency Max operating current *1 Circuit breaker current Power cable Wiring spec. *2 Cross-sectional area Connection cable Limited wiring length *1: Maximum operating current is the total current of the indoor unit and the outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
  • Page 36: Safety Devices

    11. Safety devices Model Type of protection Protection form AOYA09KLWA and AOYA12KLWA Circuit protection Current fuse (Main PCB) 250 V, 20 A Activate Fan motor stop Fan motor protection Terminal protection program After 3 minutes Reset Fan motor restart 18 A Activate Compressor stop Terminal protection program...
  • Page 37: Accessories

    12. Accessories Part name Exterior Q’ty Part name Exterior Q’ty Seal Drain joint Conection pipe- Rubber leg-optional optional Vinyl tape-optional Plaster - 33 - 12. Accessories...

This manual is also suitable for:

Asya12klwaAoya09klwaAoya12klwa

Table of Contents