1. Specifications Wall mounted Type Inverter heat pump Model Name-indoor unit ASYA09KLWA ASYA12KLWA Power supply 1ɸ , 230V, 50Hz Avaliable range 198~264V 2.64 3.52 Rated Btu/h 9000 12000 Cooling 0.91-3.11 1.11-4.16 Min.-Max. Btu/h 3100-10600 3800-14200 Capacity 2.93 3.81 Rated Btu/h...
Page 7
805x194x285 Dimensions (H × W × D) Gross 870x285x360 Weight Gross Liquid φ6.35 (φ1/4) mm (in) φ9.52 (φ3/8) Connection pipe Gass Method Flare Material Drain hose Size φ16 °C 17-32 Cooling Operation range 80 or less Heating °C 0-30 Remote controller type Wireless Cooling Energy efficiency class...
2. Dimensions 2-1. Models: ASYA09KLWA and ASYA12KLWA Unit: mm ¢ Installation space requirement Provide sufficient installation space for product safety. Unit: mm 150 or more or more or more 2,300 or more - 4 - 2-1. Models: ASYA09KLWA and ASYA12KLWA...
3. Wiring diagrams 3-1. Models: ASYA09KLWA and ASYA12KLWA Abbreviation Paraphrase Ground Connection Positive and Negative Ion Generator Capacitor PLASMA Electronic Dust Collector LIVE NEUTRAL Heater The Electric Heating Belt of Indoor Unit Indoor Room Temperature Coil Temperature of Evaporator - 5 - 3-1.
4-2. Heating capacity NOTE: Values mentioned in the table are calculated based on the maximum capacity. ¢ Model: ASYA09KLWA ¢ Model: ASYA12KLWA - 7 - 4-2. Heating capacity 4. Capacity table...
5. Fan performance 5-1. Air velocity distributions ¢ Model: ASYA09KLWA Fan speed Operation mode Measuring conditions HIGH Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left - 8 - 5-1.
Page 13
Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Right Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center - 9 - 5-1. Air velocity distributions 5.
Page 14
¢ Model: ASYA12KLWA Fan speed Operation mode Measuring conditions HIGH Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left - 10 - 5-1. Air velocity distributions 5.
Page 15
Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Right Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Side view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center - 11 - 5-1. Air velocity distributions 5.
6-2. Sound level check point 0.8m Microphone Microphone NOTES: • Sound measured at 1 m away from the center of the unit. • Data is valid at free field condition. • Data is valid at nominal operation condition. • Reference acoustic pressure 0 dB=20 μPa. •...
7. Safety devices Model Type of protection Protection form ASYA09KLWA ASYA12KLWA Circuit protection Current fuse (PCB*) 250 V, 20 A *PCB: Printed Circuit Board - 15 - 7. Safety devices...
8. Remote controller 8-1. Wireless remote controller ¢ Overview SILENCE/FP ON/OFF Used to activate silence Turns the unit on or off. and 8 C heating feature. MODE Scrolls through operation TEMP modes as follows: Increases temperate in AUTO COOL C increments. HEAT Max.
Page 21
• UP Button ( ) and DOWN Button ( Increase or decrease set temperature. NOTE: Temperature control is not available in Fan mode. • SLEEP: Select this function during the sleeping time. It keeps the most comfortable temperature and save energy. This function is available in COOL, HEAT or AUTO mode only. NOTE: While the unit is running in sleep mode, it would be cancelled if MODE, FAN SPEED or ON/OFF button is pressed.
1-9. Accessories Part name Exterior Q’ty Part name Exterior Q’ty SPL I T -TYPE ROOM AIR CONDITIONER SPLI T-TYPE ROOM AIR CONDITIONE R Installation Manual Owne r ’ s Manua l Forest Series Forest Series All Model Numbers All Model Numbers Owner’s manual Installation manual CS78421-548-754...
1. Specifications Wall mounted Type Inverter heat pump Model Name-outdoor unit AOYA09KLWA AOYA12KLWA Power supply 220-240V, 1Ph, 50Hz Available voltage range 198-264V Airflow 1700 Type × Q’ty Propeller fan × 1 Output Sound pressure level HIGH dB (A) 57.5 Cooling Sound power level dB (A) Heating...
3. Installation space 3-1. Models: AOYA09KLWA and AOYA12KLWA ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
Page 27
Multiple outdoor unit installation L ≤ 1/2H 250 mm or more L ≤ H 1/2H ˂ L ≤ H 300 mm or more L ˃ H Can not be installed Do not install the rows of series like following figure. NOTES: •...
5. Wiring diagrams 5-1. Models: AOYA09KLWA and AOYA12KLWA Abbreviation Paraphrase 4-WAY 4-WAY VALVE AC-FAN Alternating Current FAN DC-FAN Direct Current FAN AC Current Detector COMP Compressor Coil Temperature of Condenser Outdoor Ambient Temperature Compressor Discharge Temperature Electronic Expansive Valve - 25 - 5-1.
6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOYA09KLWA and AOYA12KLWA NOTE: Values mentioned in the table are calculated based on the maximum capacity.
9-2. Sound level check point Outdoor unit Microphone NOTES: • H= 0.5 × height of outdoor unit. • Sound measured at 1 m away from the center of the unit. • Data is valid at free field condition. • Data is valid at nominal operation condition. •...
10. Electrical characteristics Model name AOYA09KLWA and AOYA12KLWA Voltage 230 ~ Power supply Frequency Max operating current *1 Circuit breaker current Power cable Wiring spec. *2 Cross-sectional area Connection cable Limited wiring length *1: Maximum operating current is the total current of the indoor unit and the outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
11. Safety devices Model Type of protection Protection form AOYA09KLWA and AOYA12KLWA Circuit protection Current fuse (Main PCB) 250 V, 20 A Activate Fan motor stop Fan motor protection Terminal protection program After 3 minutes Reset Fan motor restart 18 A Activate Compressor stop Terminal protection program...