FEATURE MODEL ABG18LVTB / AOG18LALL FEATURES Energy saving High energy saving was realized by making the indoor unit and outdoor unit fan motor and compressor all DC and optimal design of the refrigerant cycle. Class A was achieved in European energy classifications.
Page 5
10°C HEAT Operation *Only available with Wireless RC. The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied Caution) • When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
WIRELESS REMOTE CONTROLLER FEATURES Four kinds of timer setup (ON / OFF / PROGRAM / SLEEP) are ¾ possible. Four kinds of timers. Easy operation. ¾ Easy to change transmission code (4 patterns) by button operation. ¾...
Page 7
FUNCTIONS MODE button Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. signal code change. (Max 4 types) 10°C HEAT button SET TEMP. button ( ▲ / ▼ ) Sets the indoor temp./ Sets R.C. signal code. ECONOMY button SLEEP button Pressed to select sleep timer.
SPECIFICATIONS FLOOR / CEILING MODEL Type INVERTER HEATPUMP Indoor unit AB¾G18LVTB Model name Outdoor unit AO¾G18LALL Power source 230V ~ 50Hz Available voltage range 198 - 264V ~ 50Hz Cooling European energy label Heating 5.20 Rated Btu/h 17700 Cooling 0.90 - 5.90 Min - Max Btu/h 3100 - 20100...
DIMENSIONS MODEL : ABG18LV (Unit : mm) Rear view Side view (Drain hose) Bottom view Wall bracket Side of set 100 hole 50 hole 100 hole AB ¾ G18LV Liquid ø 6.35 mm (ø 1/4 in.) Refrigerant pipe flare connection ø...
Page 10
INSTALLATION PLACE (Unit : mm) Left Right 300 or more 300 or more Ceiling Left Right Indoor unit 150 or more 300 or more Ceiling 20 or more Obstruction Floor - (01 - 07) -...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION Conditions MODEL : ABG18LV (UNDER CEILING) Fan speed : High Operation mode : Fan Unit : (m/s) 0.25 Top view Vertical flap : Up Horizontal flap : Center Unit : (m/s) 0.25 Top view Vertical flap : Up Horizontal flap : Right &...
Page 15
Conditions MODEL : AB ¾ G18LV (FLOOR CONSOLE) Fan speed : High Operation mode : Fan Unit : (m/s) 0.25 Top view Vertical flap : Up Horizontal flap : Center Unit : (m/s) 0.25 Top view Vertical flap : Up Horizontal flap : Right &...
7-2. AIR FLOW MODEL : ABG18LV Cooling Number of Fan speed rotations Air flow (r.p.m.) HIGH 1040 QUIET Heating Number of Fan speed rotations Air flow (r.p.m.) HIGH 1040 QUIET - (01 - 13) -...
ELECTRIC CHARACTERISTICS Model name AB ¾ G18LV Voltage 230 ~ Power supply Frequency Max. operating current 0.45 Connection cable *1) Wiring Spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005) - (01 - 16) -...
SAFETY DEVICES Model Protection form AB ¾ G18LV Circuit protection Current fuse (PCB) 250V 3.15A 138 ± 15 °C OFF Thermal protection Fan motor protection program 115 ± 15 °C ON - (01 - 17) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS See external CN102 Control input — input/output settings for CN103 — Operation status output details. 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply *10 m Signal Field supply * Make the distance from the PC board to the connected unit within 10m.
FUNCTION SETTING 12-1. INDOOR UNIT INDOOR UNIT DIP SW indoor unit address setting Jumper Wire Setting forbidden SWITCH POSITION MAIN PCB Indoor unit Printed circuit board DIP-SW SETTING Indoor unit address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
12-2. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING” according to the installation conditions using the remote controller.
Page 25
CONTENTS OF FUNCTION SETTING • Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition. After the power is turned on, perform the Function Setting on the remote control. •...
Page 26
1-4. Heater room temperature correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. ( . . .Factory setting) Setting Description Function Number Setting Value Standard ...
Page 27
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) 1.
OPTIONAL PARTS Exterior Parts name Model No. Summary Wired remote Unit control is performed by UTY-RNN ¾ M controller wired remote controller Use to connect with various External UTY-XWZX peripheral devices and air connect kit conditioner PC board. - (01 - 25) -...
Page 29
2. OUTDOOR UNIT SINGLE TYPE : AOG12LALL AOG14LALL AOG18LALL DTR_AO099E_01 2011.12.05...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO G12LALL AO G14LALL AO G18LALL Power sourse 230V ~ 50Hz Available voltage range 198 - 264V ~ 50Hz Starting current Cooling 1780 1910 2000 Airflow rate Heating 1630 1740 1910 Type ×...
DIMENSIONS MODEL : AOG12LA, AOG14LA, AOG18LA (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE This table is created using the maximum capacity. MODEL : AOG12LA Pipe length (m) COOLING 0.903 0.894 0.867 Û 1 0.964 0.918 0.909 0.881 Indoor unit is upper than 0.988 0.968 0.922...
Page 36
This table is created using the maximum capacity. MODEL : AOG14LA Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is upper than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
Page 37
This table is created using the maximum capacity. MODEL : AOG18LA Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is upper than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
AIR FLOW MODEL : AOG12LA Cooling Number of rotations Air flow (r.p.m.) 1780 1048 Heating Number of rotations Air flow (r.p.m.) 1630 MODEL : AOG14LA Cooling Number of rotations Air flow (r.p.m.) 1910 1124 Heating ...
Page 40
MODEL : AOG18LA Cooling Number of rotations Air flow (r.p.m.) 2000 1177 Heating Number of rotations Air flow (r.p.m.) 1910 1124 - (02 - 10) -...
ELECTRIC CHARACTERISTICS Model name AO G12LA AO G14LA AO G18LA Voltage 230 ~ Power supply Frequency *1) Max operating current 10.0 12.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit.
SAFETY DEVICES Model Protection form AO G12LA AO G14LA AO G18LA Current fuse 20A 250V (NEAR THE TERMINAL) 5A 250V Circuit protection Current fuse 15A 250V (MAIN PRINTED CIRCUIT BOARD) 3.15A 250V Thermal protection OFF : 100 °C Fan motor protection program...