4. Existing wires connected to the “Handset” terminals on control must be moved from there to terminals 3 and 4 on the 4286. 5. Place a 2 conductor wire between terminals 21 and 22 to terminals 1 and 2 on the 4286. Figure 1: Vista-10/15/20p Wiring...
Figure 2: Vista-40/50/128b/bp & 250bp Figure 3: Vista-32fb & 128fb/fbp & 250fbp System Programming: Notes: 1. The 4286 has a Non-Changeable address of 04 and can not be changed. See below for programming on various panels: Back to Top Tech Support...
Page 3
Step-by-Step Programming the Vista 10/15/20p: 1. There is no device programming on these panels. In order to program the panel to recognize the 4286 you simply add the “Voice Module Access Code” Access Code for Phone Module [00] 00 = disable...
Page 4
4286 1 time accessing and programming: 1. To Access the 4286 programming, pick up any phone that is tied to terminals 3 & 4 on the 4286 and enter your 2 digit phone code. The system will give you the status of the Control Panel.
Page 5
Step-by-Step Control Panel Type Enter 1 for the Vista-10, 10se-Via30p,30pse – 4140xmp Enter 2 for the Vista-10/15/20p, Vista-20, 20HW, 20SE, 20HWSE & Vista- Enter 4 for the Vista-40, 50p, 128b/bp, 250bp and 128fb/fbp and 250fbp For Integration of the 4500 Thermostat module complete the following: Units of Temperature 1 –...
Page 6
Step-by-Step 000 – No Announcement (See Below for word list) Word Word Word Word Index Index Index Index Word Word Word Word DOWNSTAIRS MEDICAL STORAGE ALARM DRIVEWAY MOTHERS DUCT MOTION SYSTEM* APARTMENT APPLIANCE EAST TEMPERATURE AREA EQUIPMENT NORTH TOOL ATTIC EXIT BABY FACTORY...
Page 7
HVAC contractor be contacted for information on the type of heating system and the amount of "span" (i.e. temperature swing) that should be set with the 4286 phone module. 5. For more wiring notes see the installation instructions.
Page 8
Step-by-Step Figure 11: Addressing the 4500 Basic operations are: 1. 4500 is used to operate the HVAC system with the alarm panel is armed in the AWAY or MAXIMUM mode. Premises Thermostat should be set above (in heat mode) or below (in cool mode) the 4500 Set-back setting.
Setting the 4500 Thermostat: To enter and use the 4286 thermostat programming mode: 1. There must be at least one thermostat programmed into the system by way of the 4286 installer programming mode entry. 2. Obtain phone access from the phone module. Enter the 2-digit phone code. Enter the 4-digit system code if prompted.
Page 10
4286 programming mode. See figure 11 above 2. Check the connections from the 4286 to the 4500, and make sure that the cable connecting the 4500s to the 4286 faces the correct direction (yellow toward the corner of the 4286 board).
Page 11
Check the wiring of the 4286 on the ECP terminals of the panel. Make sure the harness is plugged into the proper plug on the 4286, and not the plug intended for the 4500, make sure it is plugged in with yellow towards the center of the board.