Problem solving guide
Other problems
Problem
A buzzer is sounding.
An LED indicator light is
flashing at the back of
the refrigeration appli-
ance at the bottom near
the compressor (de-
pending on model).
The electronic unit for
the compressor is
equipped with an oper-
ation and fault dia-
gnosis LED indicator
light.
The external walls of
the appliance feel
warm.
The door seal is dam-
aged or needs to be re-
placed.
The floor of the refriger-
ator section is wet.
42
Cause and remedy
The door alarm has been activated.
Close the appliance door. The buzzer will stop.
The indicator light flashes several times every
5 seconds.
A fault has occurred.
Call the Miele Customer Service Department.
The indicator light flashes regularly every
15 seconds.
Not a fault. This flashing is normal.
This is not a fault. The heat created by the evapor-
ator is used to prevent condensation.
No tools are required to change the door seal.
Change the door seal. A replacement is available
from Miele or from specialist retailers.
The condensate drain hole is blocked.
Clean the condensate channel and drain hole.