Page 3
SAFETY NOTICE ... LIST OF MATERIALS ... INSTALLATION Ducting Calculation Sheet ... Mounting Height and Clearance ... Ducting ... Specifications ... Mounting the Hood and Duct Cover... Ductless Recirculating ... FEATURES & CONTROLS Touch Controls & Features ... Charcoal Filter Change Indicator ... Metal Filter Clean Indicator ...
Page 4
READ AND SAVE THESE INSTRUCTIONS WARNING TO RE DUCE TH E R IS K O F FIR E O R E LE C TR IC SHOC K, DO NOT US E TH IS FAN W ITH ANY S O LID-S TATE SP E E D C O NTRO L DEV IC E.
Page 5
1 - Packet of mounting screws w/anchors 1 - Butterfly damper NO DUCTING IS INCLUDED * Note: Zephyr recommends using 50LB EZ anchors if mounting hood onto drywall. These are not provided. but are readily available of most hardware stores.
Page 6
Equivalent number Duct pieces length x used 3 1/4” x 10” 1 Ft. Rect., straight 7” Round, 1 Ft. straight 7” Round, 1 Ft. straight 3 1/4” x 10” 15 Ft. Rect. 90 elbow 3 1/4” x 10” 9 Ft. Rect.
min. ducted - 32 1/2” min recirc. - 36” max. 51” 9-27/32" min. 28" - max. 36" * min. 97" ** max. 123" 36" DUCTING A minimum of 6" round or 3-1/4 x 10" rectangular duct must be used to maintain maximum air flow efficiency.
Page 8
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. Some Ducting Options: side wall cap w/ gravity damper...
1.87" 0.5" 2.78" 6.5" 6" 10.37" 13.87" 3/4" Elec. K.O. ELECTRICAL - WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance.
1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/L (9-7/16”) 5. Fasten E-Z anchors to wall (see below) as marked. 6.
Page 11
RECIRCULATING KIT (Required) 1. Kit includes charcoal filters and air diverter plate: Hood Model: Part No. Filters in pkg. ZVE-E30S ZRC-0050 ZVE-E36S ZRC-0051 ZVE-E42S ZRC-0051 2. Remove metal filters on hood. Clip chacoal filters onto difuser panels.
Page 12
1. Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by presing level selected. 3. Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated.
Filter Change Reminder (Charcoal, if fitted): When your hood is installed as a 'Recirculating' (Ductless) unit, it is fitted with a set of Charcoal Filters to purify exhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are required to be replaced after every 120 hours of use.
Page 14
Filter Clean Reminder (Standard Metal Filters fitted): Whether your hood is installed as an Exhaust or Purifying unit, a set of metal filters are fitted by the factory. These Metal Filters are intended to filter out residue from cooking. They need not be replaced on a regular basis but are required to be kept clean.
Dry filters and re-install before using hood. Replacing Metal Filters Should filters wear out due to age and prolonged use, replace with following part number: Hood Model: Part No. Filters in pkg. ZVE-E30S Z0F-MO42 ZVE-E36S Z0F-MO43 ZVE-E42S Z0F-MO43 Also replace any damaged filter that has punctured or broken mesh, bent or broken frame.
Replacing Light Bulbs CAUTION: Light bulb becomes extremely hot when turned on. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approx.
Page 17
s s I After installation, the unit 1. The power source is not turned ON. doesn’t work? 2. The power line and the cable locking connector is not connecting properly. 3. The switch board and control board wirings are disconnected. 4.
Page 18
Description Light Bulb (JDR-E27) Metallic Filters (2 pk) Metallic Filters (3 pk) Telescopic Back Splash 30” Telescopic Back Splash 36” Telescopic Back Splash 42” Wire Spice Rack 30” Wire Spice Rack 36” Wire Spice Rack 42” To order parts, visit us online at : www.zephyronline.com and go to the parts store. Or call us at : 888-880-8368 Part# Z0B-0011...
Page 19
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instruc- tions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr's Authorized Agents. What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.