Setting the gas pressure
The gas pressure must be set by the
approved gas fitter as shown on the
data plate:
Natural gas 1.0 kPa
ULPG (Propane/Butane) 2.75 kPa
The gas pressure must be set with the
largest burner operating at maximum
setting.
a Connection R ¹/₂" with test point
b Connection R ¹/₂" with test point and
90° angle
When using a 90° angle the building-
in depth will increase to the depth of
the elbow used.
The gas regulator is only included with
appliances which are set up for
connection to natural gas.
a Pressure Test Point
Loosen the screw in the test point
a
Connect the hose from the pressure
Reassemble one of the large burners,
b
Disconnect gauge and screw in the
Gas connection
a
until it is free in its housing. The
screw is retained in this position.
gauge.
turn on the gas and manually light the
burners.
test point screw.