Problem solving guide
Problem
The red LED flashes and
F2081 warning
the message
is shown on the display.
The red LED flashes and
the message
F1 fault
shown on the display.
32
Cause and remedy
The main filter no longer works and must be replaced.
Contact the Miele Customer Service Department or re-
place the main filter (see "Cleaning and care – Filter re-
placement"). In order to temporarily achieve the original
air throughput when the main filter has stopped working,
the air throughput rate can be manually increased until
the filter is replaced (e.g. by changing the room size from
60 m² to 80 m² in the Settings menu or by manually in-
creasing the fan speed).
This message can be hidden temporarily by pressing the
and buttons briefly at the same time (<1 sec).
The internal thermal sensor is defective.
is
Contact the Miele Customer Service Department.
This message can be hidden temporarily by pressing the
and buttons briefly at the same time (<1 sec).