Temperature and humidity range
● The temperature and humidity required for operating this product is as
shown in the following table.
Cooling/Dry Mode
Outdoor
Please refer to the specification of outdoor units.
temperature
Indoor
About 18 to 32 °C DB
temperature
Indoor humidity
About 80% or less
● If the air conditioner is operated under higher temperature conditions
than those listed, the built-in protection circuit may operate to prevent
internal circuit damage. Also, during Cooling and Dry modes, if the unit
is used under conditions of lower temperature than those listed above,
the heat-exchanger may freeze, leading to water leakage and other
damage.
● If the unit is used for long periods under high-humidity conditions,
condensation may form on the surface of the indoor unit, and drip onto
the floor or other objects underneath.
● Do not use this unit for any purposes other than the Cooling, Heating,
Dehumidifying, and air-circulation of rooms in ordinary dwellings.
CLEANING AND CARE
CAUTION
● Before cleaning the unit, be sure to stop the unit and disconnect the
power supply.
● Do not stand on an unstable platform when cleaning.
● When removing and replacing the air filters, be sure not to touch the
heat exchanger, as personal injury may result.
● Do not clean the inside of the unit by yourself. To clean the inside,
always consult authorized service personnel.
● Be sure the intake grille is installed securely.
● When cleaning the unit's body, do not use water hotter than 40 °C,
harsh abrasive cleansers, or volatile agents like benzene or thinner.
● If dirt is allowed to accumulate on the air filter, airflow will be reduced,
lowering operating efficiency and increasing noise.
● AB*A 012/014/018/024
During periods of normal use, the air filters should be cleaned every
two weeks.
● AB*A 030/036/045/054
During periods of normal use, the air filters should be cleaned every
four weeks.
Cleaning the air filter
● AB*A 012/014/018/024
1. Remove the air filter.
1 Pull out both sides and the center of the intake grille.
2 Pull the air filters upward to remove them.
About
30 mm
Arm
Intake Grille
Handle
En-3
Heating Mode
About 10 to 30 °C DB
Side Panel
Hook
Notch
Arm
2
Air Filter
Bracket
Base
Intake
Grille
2. Cleaning
Cleaning the Air filter
Remove dust with a vacuum cleaner or by washing. After washing, be
sure to allow it to dry thoroughly in a shady place before reinstalling.
3. Re-attach the air filters to the intake grille.
1 The air filters fit onto the inside of the intake grille.
2 The bottom edges of the air filters should fit into the filter brackets.
3 The air filters should be pushed down so that their top edges fit
under the projections at the top of the intake grille.
4 Push in both sides and the center of the intake grille.
Air Filter
1 2
3
Filter bracket
● AB*A 030/036/045/054
1. Remove the air filter.
Remove the air filters by raising its handle while pulling it out towards
you.
Air filter
2. Cleaning
Cleaning the Air filter
Remove dust with a vacuum cleaner or by washing. After washing, be
sure to allow it to dry thoroughly in a shady place before reinstalling.
3. Re-attach the air filters to the intake grille.
The air filters fit onto the inside of the intake grille.
Cleaning the body
Wash the body with warm water, and then dry with a clean and soft
cloth.
When not using for an extended period
Leave the breaker on for at least 12 hours before starting operation
when it is to be used again.
TROUBLESHOOTING
The following conditions are not breakdowns or op-
eration failures.
Doesn't operate immediately:
● If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent fuse
blowouts.
● Whenever the electrical breaker is turned off then on again, the protec-
tion circuit will operate for about 3 minutes, preventing unit operation
during that period.
Airflow is weak or stops:
● When Heating operation is started, indoor unit's fan may temporarily
stop, to allow internal parts to warm up.
● During Heating operation, if the room temperature rises above the
thermostat setting, the outdoor unit will stop, and the indoor unit's fan
will stop. If you wish to warm the room further, set the thermostat for a
higher setting.
4
4
4