Problem
The compressor comes
on less and less often
and for shorter periods
of time. The tempera-
ture in the appliance
rises.
Ice or condensation has
built up inside the re-
frigeration appliance.
The appliance door may
not close correctly.
The door seal is dam-
aged or needs to be re-
placed.
90
Possible cause and solution
This is not a fault. The temperature setting is too
high.
 Correct the temperature setting.
 Check the temperature again after 24 hours.
The food begins to thaw.
The ambient temperature is too low for this appli-
ance.
If the ambient temperature is too low, the compres-
sor will run less frequently. This may cause the
freezer to become too warm.
 See the information in the section on "Installation –
Installation location".
 Increase the ambient temperature.
The door seal has come out of its groove.
 Check that the door seal is correctly positioned in
the groove.
The door seal is damaged.
 Check whether the door seal is damaged.
No tools are required to change the door seal.
 Change the door seal. A replacement is available
from Technical Service.