FEATURES MODEL ARG24LMLA / AOG24LALA FEATURES Energy efficiency class MODEL AR G24LMLA Cooling Heating Installation styles Embedded in Ceiling Hanging from Ceiling Slim & compact design In the case of bottom suction type, as seen from lower rear part. Control Box united with main unit One-touch operating and easy-to-install long-life filter (optional)
Page 5
Easy maintenance The fan and motor is easily accessible by the divided panel structure. 1. Control box Structural improvement is attained by making the bottom panel in two pieces, front and rear. 2. Fan casing The internal fan casing is also manufactured in two 3.
WIRED REMOTE CONTROLLER FEATURES Various timer setup available (ON / OFF / WEEKLY). Equipped with weekly timer as standard function.(Start/Stop function is twice per day for a week) When setting up the timer, operation mode and temperature setup ...
Page 7
FUNCTIONS START/STOP button Pressed to start and stop operation. SET TEMP. button Selects the setting temperature. MODE button Selects the operating mode (AUTO, HEAT, FAN, COOL, DRY). FAN button Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH). ECONOMY button Turns the economy efficient mode on and off.
DIMENSIONS MODEL : AR G24LMLA (Unit : mm) Front view Side view (L) Side view (R) Top view Rear view Refrigerant piping flare connection (Gas) Refrigerant piping flare connection (Liquid) Drain piping connection Drain piping connection with cap. ...
Page 11
INSTALLATION PLACE (Unit : mm) MAINTENANCE HOLE It is possible to install and remove the control It is possible to install and remove the control box. box, fan units and filter. WHEN USING A SQUARE DUCT ...
ELECTRIC CHARACTERISTICS Model name ARG24LMLA Voltage 230 ~ Power supply Frequency Max. operating current Connection cable 1.5~2.5 *1) Wiring spec. Limited wiring length *1) Wiring Spec. Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005) - (01 - 18) -...
SAFETY DEVICES Model Protection form ARG24LMLA Circuit protection Current fuse (PCB) 250V 3.15A OFF : 135 ± 15°C Fan motor protection Thermal protection program ON : 115 ± 15°C - (01 - 19) -...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply *10 m Signal Field supply * Make the distance from the PC board to the connected unit within 10m.
Page 25
FRESH AIR CONTROL OUTPUT A signal linked to air conditioner indoor fan ON can be output. * However, signal becomes OFF during cold air prevention control operation. Circuit diagram example Indoor unit Connected unit control PC board Ex.) Fan Ex.) Relay unit 12 V...
Page 26
AUXILIARY HEATER OUTPUT A signal is outputed from Connector when indoor fan and compressor is turned on under heating operation. Tr-Ts * Signal output performance specifications are as Tr-Ts = -1°C shown on the right Tr-Ts = -3°C Ex.
FUNCTION SETTINGS 12-1. INDOOR UNIT INDOOR UNIT DIP SW Remote controller address setting Setting forbidden Jumper Wire Fan delay setting SWITCH POSITION DIP-SW SETTING Remote controller address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
Page 28
JUMPER WIRE SETTING Setting forbidden (JM1, JM2) Fan delay setting (JM3) When the indoor unit is stopped while operating in conjunction with auxiliary heater, the indoor unit fan operation will continue for one minute. ( . . .Factory setting) JM 3 JM state Connect...
12-2. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit to malfunction. • After the power is turned on, perform the Function Setting according to the installation conditions using the remote controller.
Page 30
(5) Press the TIMER SET button to confirm the setting. Press the TIMER SET button for a few seconds until the setting value stops flashing. If the setting value display changes or if “- -” is displayed when the flashing stops, the setting value has not been set correctly. (An invalid setting value may have been selected for the indoor unit.) (6) Repeat steps 2 to 5 to perform additional settings.
Page 31
4) Setting the Heater Room Temperature Correction Depending on the installed environment, the room temperature sensor may require a correction. The settings may be changed as shown in the table below. ( . . .Factory setting) Setting Description Function Numbe Setting Value Standard ...
Page 32
10) Indoor unit fan control for energy saving (Only cooling mode) Enable or disable indoor unit fan control when the outdoor unit is stopped. ( . . .Factory setting) Setting Description Function Numbe Setting Value * If setting value is "00": When the outdoor unit is stopped, the indoor unit fan operates following the setting on the remote controller continuously.
OPTIONAL PARTS 13-1. CONTROLLER Exterior Parts name Model No. Summary Large and full-dot liquid crystal Wired remote screen, wide and large keys UTY-RVN M controller easy to press, user-intuitive arrow key. The room temperature can Wired remote be controlled by detecting the UTY-RNN ...
13-2. OTHERS Exterior Parts name Model No. Summary Square flange UTD-SF045T Both the Square flange and the Round flange can be selected. Round flange is also used when the fresh air duct is installed Round flange UTD-RF204 Long-life filter can be Long-life filter UTD-LF25NA mounted to the indoor unit.
Page 36
2. OUTDOOR UNIT SINGLE TYPE : AOG12LALL AOG14LALL AOG18LALL AOG24LALA DTR_AO099E_02 2013.02.28...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AO G12LALL AO G14LALL AO G18LALL AO G24LALA Power source 230V ~ 50Hz Available voltage range 198 - 264V ~ 50Hz Starting current Cooling 1780 1910 2000 2470 Airflow rate Heating 1630 1740...
DIMENSIONS MODEL : AOG12LALL, AOG14LALL, AOG18LALL, AOG24LALA (Unit : mm) Top view Front view AO G12LALL AO G24LALA AO G14LALL AO G18LALL Air flow Side view Bottom view INSTALLATION PLACE When there are obstacles at When there are obstacles at When there are obstacles at the the back or front sides.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFFERENCE This table is created using the maximum capacity. MODEL : AOG12LALL Pipe length (m) COOLING 0.903 0.894 0.867 Û 1 0.964 0.918 0.909 0.881 Indoor unit is higher than 0.988 0.968 0.922...
Page 44
This table is created using the maximum capacity. MODEL : AOG14LALL Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is higher than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
Page 45
This table is created using the maximum capacity. MODEL : AOG18LALL Pipe length (m) COOLING 0.953 0.950 0.947 Û 1 0.983 0.968 0.966 0.962 Indoor unit is higher than 0.988 0.987 0.972 0.970 0.966 outdoor unit. 0.992 0.992 0.991 0.976 0.974...
Page 46
This table is created using the maximum capacity. MODEL : AOG24LALA Pipe length (m) COOLING 0.963 0.961 0.959 Û 1 0.984 0.981 0.979 0.977 0.975 Indoor unit is higher than 0.988 0.988 0.985 0.983 0.981 0.979 outdoor unit. 0.992 0.992 0.992...
AIRFLOW MODEL : AOG12LALL Cooling Number of rotations Airflow (r.p.m.) 1780 1048 Heating Number of rotations Airflow (r.p.m.) 1630 MODEL : AOG14LALL Cooling Number of rotations Airflow (r.p.m.) 1910 1124 Heating Number of rotations Airflow (r.p.m.)
Page 49
MODEL : AOG18LALL Cooling Number of rotations Airflow (r.p.m.) 2000 1177 Heating Number of rotations Airflow (r.p.m.) 1910 1124 MODEL : AOG24LALA Cooling Number of rotations Airflow (r.p.m.) 2470 1050 1454 Heating Number of rotations Airflow...
ELECTRIC CHARACTERISTICS Model name AOG12LALL AOG14LALL AOG18LALL AOG24LALA Voltage 230 ~ Power supply Frequency *1) Max operating current 10.0 12.5 13.5 Starting Current Main Fuse (Circuit breaker) *2) Wiring Spec. Current Power Cable *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standards and Codes Committee E0005)
SAFETY DEVICES Model Protection form AO G12LALL AO G14LALL AO G18LALL AO G24LALA 250V 20A Current fuse (Near the terminal) 250V 5A Circuit protection Current fuse 250V 15A (Main printed 250V 3.15A circuit board) Fan motor Thermal protection OFF : 100 °C...