10. RF CALIBRATION
10.1.2 Basic Setting of Tachyon for RF Calibration & Test
[ System Option Setting]
Procedure
1. Click "Tachyon_xxx.exe" in below directory to execute Tachyon program. "C:\LGE\Tachyon\"
2. Click "System Option Setting" icon in the menu to set COM port.
Select "UART Port" that can communicate with phone in the Shield Box 1 message.
Click the "OK" button.
. Click "User Model Selection" icon in the menu to set model configuration.
Do double-click model/buyer name that you want to calibrate and test.
Click the "Select" button.
LGE Internal Use Only
[ User Model Selection]
- 150 -
Copyright © 2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes