Installation notes
Installation requirements
The flatwork ironer must only be set up by a Miele authorised and trained service techni-
cian or an authorised dealer.
This flatwork ironer must be installed in accordance with all relevant regulations and
standards. Local energy supplier regulations must also be observed.
This flatwork ironer must only be operated in a room that has sufficient ventilation and
which is frost-free.
Operating conditions
In general, the operating conditions of DIN 60204 and EN 60204-1 apply.
- Ambient temperature: +5 °C to +40 °C
- Humidity: 10 % to 85 %
- At +21 °C ambient temperature, the maximum permissible relative humidity is 70 %.
- Maximum height above sea level of location site: 1000 m
The ironer must not be operated in the same room as dry-cleaning equipment using
perchloroethylene or solvents containing CFCs.
Collector motor sparking may convert solvent vapours into hydrochloric acid which can
lead to consequential damage.
Ensure adequate ventilation is present in the room in which the ironer is installed whilst it
is being used.
Floor anchoring
Measures to secure the ironer in place on the floor are essential.
The ironer must be secured to the floor after installation using the plugs and screws sup-
plied.
The fittings supplied are for bolting the machine to a concrete floor. For other types of
flooring, please purchase suitable fastening materials separately.
Electrical connection
The electrical connection must be carried out by a qualified electrician who must ensure
that all electrical work is carried out in accordance with applicable regulations and
standards.
It is recommended to connect the ironer to the electrical supply via a suitably rated plug
and socket.
The electrical connection and wiring diagram are located behind the mounting flap of the
right-hand side column.