Page 2
IMPORTANT SAFETY NOTICE Proper service and repair is important to the safe, reliable operation of all P&F Equipment. The service procedures recommended by P&F and described in this service manual are effective methods of performing service operations. Some of these service special tools should be used when and as recommended.
IMPORTANT SAFETY PRECAUTIONS Prior to shipment from the factory, our products are strictly inspected for recognized product safety and electrical codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally important to implement the following precautions when a set is being serviced.
Page 6
3. Design Alteration Warning - Do not alter or add 7. Product Safety Notice - Some electrical and to the mechanical or electrical design of this TV mechanical parts have special safety-related receiver. Design alterations and additions, characteristics which are often not evident from including, but not limited to circuit modifications visual inspection, nor can the protection they give and the addition of items such as auxiliary audio...
Page 7
Precautions during Servicing A. Parts identified by the # symbol are critical for safety. Replace only with part number specified. B. In addition to safety, other parts and assemblies are specified for conformance with regulations applying to spurious radiation. These must also be replaced only with specified replacements.
Page 8
Safety Check after Servicing Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts and wires have been returned to original positions. Afterwards, perform the following tests and confirm the specified values in order to verify compliance with safety standards. 1.
STANDARD NOTES FOR SERVICING Circuit Board Indications How to Remove / Install Flat Pack-IC 1. The output pin of the 3 pin Regulator ICs is 1. Removal indicated as shown. With Hot-Air Flat Pack-IC Desoldering Machine: Top View 1. Prepare the hot-air flat pack-IC desoldering Bottom View machine, then apply hot air to the Flat Pack-IC Input...
Page 10
3. The flat pack-IC on the CBA is affixed with glue, so With Soldering Iron: be careful not to break or damage the foil of each 1. Using desoldering braid, remove the solder from pin or the solder lands under the IC when all pins of the flat pack-IC.
Page 11
2. Installation With Iron Wire: 1. Using desoldering braid, remove the solder from 1. Using desoldering braid, remove the solder from all pins of the flat pack-IC. When you use solder the foil of each pin of the flat pack-IC on the CBA flux which is applied to all pins of the flat pack-IC, so you can install a replacement flat pack-IC more you can remove it easily.
Page 12
Instructions for Handling Semi- conductors Electrostatic breakdown of the semi-conductors may occur due to a potential difference caused by electrostatic charge during unpacking or repair work. 1. Ground for Human Body Be sure to wear a grounding band (1 MΩ) that is properly grounded to remove any static electricity that may be charged on the body.
CABINET DISASSEMBLY INSTRUCTIONS 1. Disassembly Flowchart Step/ Fig. Loc. Part Removal Note This flowchart indicates the disassembly steps for the cabinet parts and the CBA in order to gain access to Power items to be serviced. When reassembling, follow the 11(S-9), CN1801, Supply steps in reverse order.
Page 15
[4] Stand Bracket Shield Plate [5] IR Sensor (S-6) CBA Unit (S-7) (S-8) (S-5) CL1601 [6] Function (S-8) CBA Unit (S-6) [3] Speaker Function Button AC Inlet Holder Knob Frame Fig. D2 PL11.7-A_DC...
Page 16
[9] FRC CBA Unit FRC Shield Box (S-11) Wireless LAN Adaptor Shield Box Jack Holder A (S-10) (S-10) [8] Digital Main Jack Holder B CBA Unit (S-9) (S-9) [7] Power Supply CBA (S-9) Fig. D3 PL11.7-A_DC...
Page 18
TV Cable Wiring Diagram To LCD Module Assembly To LCD Module Assembly CN5004 CN5003 CN5002 CN5001 FRC CBA Unit Power Supply CBA Digital Main CBA Unit CN1913 CN1801 CN1914 CN3101 CN3901 CN3801 CN3102 CN1601 Function To AC Inlet CBA Unit To Speaker CN4001 IR Sensor CBA Unit...
ELECTRICAL ADJUSTMENT INSTRUCTIONS General Note: “CBA” is abbreviation for 1. Purity Check Mode “Circuit Board Assembly.” This mode cycles through full-screen displays of red, Note: Electrical adjustments are required after green, blue, and white to check for non-active pixels. replacing circuit components and certain 1.
Page 20
The White Balance Adjustment should be 5. Press [3] button to select the “HDB” for High Drive Blue adjustment. (“HDB” appears on the screen.) performed when replacing the LCD Panel 6. Press [MENU] button. The internal Raster signal or Digital Main CBA. appears on the screen.
Page 21
13. Press [9] button to select the “LDB” for Low Drive Blue adjustment (“LDB” appears on the screen.) and press [CH + or -] buttons to adjust the color temperature. Internal(Single) LDB 0 14. Press [7] button to select the “LDR” for Low Drive Red adjustment (“LDR”...
HOW TO INITIALIZE THE LCD TV The purpose of initialization is to place the set in a new out of box condition. The customer will be prompted to select a language and program channels after the set has been initialized. To put the program back at the factory-default, initialize the LCD TV using the following procedure.
FIRMWARE RENEWAL MODE Equipment Required (Files included in the USB storage device are displayed.) a. USB storage device " * " differs depending on the models. b. Remote Control Unit *****_******.upg Select an upgrade file Firmware Update Procedure *****_******.upg *****_******.upg 1.
TROUBLESHOOTING FLOW CHART NO.1 The power cannot be turned on. Is the fuse (F1601) normal? See FLOW CHART No.2 <The fuse blows out.> Check if there is any leak or short-circuiting on the primary circuit component, and service it if defective. (D1202, D1205, D1208, IC1201, T1201, R1202, R1203, C1202) Is the AL+5V line voltage normal?
Page 25
FLOW CHART NO.5 AL+5V is not output. Check C1102, D1102 and their periphery circuit, and service it if defective. FLOW CHART NO.6 PANEL+24V is not output. Check C1725, C1727, C1728, D1714, D1715 and their periphery circuit, and service it if defective. FLOW CHART NO.7 P-ON+12V is not output.
Page 26
FLOW CHART NO.9 No operation is possible from the remote control unit. (Operation is possible from the unit.) Check AL+3.3V line and service it if defective. Replace the IR Sensor CBA Unit or the remote control unit. Replace the IR Sensor CBA Unit. Replace Digital Main CBA Unit.
SCHEMATIC DIAGRAMS / CBA AND TEST POINTS Standard Notes WARNING Many electrical and mechanical parts in this chassis have special characteristics. These characteristics often pass unnoticed and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc.
Page 32
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON THE FOLLOWING PAGES: 1. CAUTION: CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE_A,_V FUSE. ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE MÊME TYPE DE_A,_V. 2.
Page 33
Power Supply 1 Schematic Diagram CAUTION ! Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. NOTE: If Main Fuse (F1601) is blown , check to see that all components in the power supply CAUTION ! : For continued protection against risk of fire, The voltage for parts in hot circuit is measured using circuit are not defective before you connect the AC plug to the AC power supply.
Page 34
Power Supply 2 Schematic Diagram NOTE: The voltage for parts in hot circuit is measured using hot GND as a common terminal. POWER SUPPLY CBA HOT CIRCUIT. BE CAREFUL. TO LCD MODULE CN1913 ASSEMBLY 24.3 1 PANEL+24V 24.3 D1717 R1774 R1775 R1776 R1777...
Page 35
Digital Main 1 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. IC3704 CONTINUE DIGITAL MAIN CBA UNIT...
Page 36
Digital Main 2 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. DIGITAL MAIN CBA UNIT IC3104(2/8) MN2WS0170...
Page 37
Digital Main 3 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. (NO CONNECTION) CN3111 GND 2...
Page 38
Digital Main 4 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. JK3707 DIGITAL MAIN CBA UNIT SERVICE...
Page 39
Digital Main 5 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. DIGITAL MAIN CBA UNIT CONTINUE DIGITAL 8...
Page 40
Digital Main 6 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. IC3104(6/8) DIGITAL MAIN CBA UNIT MN2WS0170...
Page 41
Digital Main 7 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. CONTINUE DIGITAL 6 P-ON+3.3V...
Page 42
Digital Main 8 Schematic Diagram DIGITAL MAIN CBA UNIT R3607 Q3601 2SA1576UBTLQ C3604 OPEN (SWITCHING) R3608 R3609 R3610 4.7K D3614 180K IC3601 1SS133 R3631 Q3602 BD9329EFJ-E2 2SC4081UBTLQ (+3.3V REG.) C3626 R3611 (SWITCHING) R3637 OPEN C3665 OPEN OPEN C3612 C3607 0.047 IC3606 C3609 C3616...
Page 43
Digital Main 9 Schematic Diagram SPEAKER R-CH CN3801 SP(R)- R3819 SP3801 C3802 C3816 SP(R)+ 0.47 470P C3806 D3803 D3804 C3804 C3815 SP(L)- R3881 OPEN OPEN OPEN 0.47 470P OPEN SP(L)+ SP3802 C3838 C3825 C3805 L3801 C3830 C3803 Q3801 L3802 470/16V 1000P 0.47 22uH...
Page 44
Digital Main 10 Schematic Diagram 1 NOTE: The order of pins shown in this diagram is different from that of actual IC3104. IC3104 is divided into eight and shown as IC3104 (1/8) ~ IC3104 (8/8) in this Digital Main Schematic Diagram Section. DIGITAL MAIN CBA UNIT CN3706 (ETHERNET CONNECTOR)
Page 45
Function Schematic Diagram FUNCTION CBA UNIT TO IR SENSOR CBA UNIT CN4051 CN4001 R4006 KEY-IN1 C4002 D4001 OPEN D4002 OPEN R4005 R4004 R4003 R4002 R4001 2.2K 2.7K 4.7K SW4006 SW4005 SW4004 SW4003 SW4002 SW4001 POWER CH UP SOURCE DOWN DOWN UNLESS OTHERWISE SPECIFIED: SWITCHES ARE SKRMAAE010.
Page 46
IR Sensor Schematic Diagram C4054 RS4051 GP1USC32XP (REMOTE SENSOR) D4051 SMLE12WBC7W1HR POWER TO DIGITAL MAIN R4051 R4052 R4053 CN4052 CBA UNIT CN3102 6.8K 4.7K R4054 1 GND 2 REMOTE 3 AL+3.3V 4 P-ON+5V C4051 C4056 C4052 1000P 5 LED1 6 KEY-IN1 C4053 C4055 R4055...
Page 47
FRC 1 Schematic Diagram 2 NOTE: The order of pins shown in this diagram is different from that of actual IC5001. IC5001 is divided into five and shown as IC5001 (1/5) ~ IC5001 (5/5) in this FRC Schematic Diagram Section. FRC CBA UNIT CONTINUE FRC 5...
Page 48
FRC 2 Schematic Diagram 2 NOTE: The order of pins shown in this diagram is different from that of actual IC5001. IC5001 is divided into five and shown as IC5001 (1/5) ~ IC5001 (5/5) in this FRC Schematic Diagram Section. FRC CBA UNIT IC5001(2/5) CONTINUE...
Page 49
FRC 3 Schematic Diagram 2 NOTE: The order of pins shown in this diagram is different from that of actual IC5001. IC5001 is divided into five and shown as IC5001 (1/5) ~ IC5001 (5/5) in this FRC Schematic Diagram Section. CONTINUE FRC 5 P-ON+3.3V...
Page 50
FRC 4 Schematic Diagram 2 NOTE: The order of pins shown in this diagram is different from that of actual IC5001. IC5001 is divided into five and shown as IC5001 (1/5) ~ IC5001 (5/5) in this FRC Schematic Diagram Section. FRC CBA UNIT CONTINUE FRC 5...
Page 51
FRC 5 Schematic Diagram 2 NOTE: The order of pins shown in this diagram is different from that of actual IC5001. IC5001 is divided into five and shown as IC5001 (1/5) ~ IC5001 (5/5) in this FRC Schematic Diagram Section. FRC CBA UNIT IC5001(5/5) PNX5100EH...
Page 52
Power Supply CBA Top View Because a hot chassis ground is present in the power supply CAUTION ! circuit, an isolation transformer must be used when repairing. Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. CAUTION ! : For continued protection against risk of fire, Also, in order to have the ability to increase the input slowly,...
Page 53
Power Supply CBA Bottom View CAUTION ! Because a hot chassis ground is present in the power supply circuit, an isolation transformer must be used when repairing. Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit. CAUTION ! : For continued protection against risk of fire, Also, in order to have the ability to increase the input slowly,...
EXPLODED VIEWS Cabinet CL5004 CL5003 FRC CBA Unit CL1913 TH5001 TH3104 B18 USB-1 CL3102 A5 A32 IR Sensor CBA Unit CL3901 Digital Main CBA Unit Function CBA Unit CL4051 LCD-1 CL1801 CL1914 L2 B10 CL1601 SP3802 L6 L2 CL3801 SP3801 Power Supply CBA See Electrical Parts List for parts with this mark.