FEATURES MODEL ABG30LRTE / AOG30LETL ABG36LRTE / AOG36LETL FEATURES Energy efficiency class MODEL AB G30LRTE AB G36LRTE Cooling Heating Quiet operation Air flow mode can be set in 4 steps and more detailed air flow setting is possible. 30 type: 32 dB / 36 type: 32 dB at operation in the Quiet mode.
Page 5
Fresh-air intake Fresh-air INDOOR OUTDOOR FUNCTION SETTINGS Ceiling switching function (standard/high ceiling) Also delivers air to high ceilings by selecting the mode and raising the air flow according to the height of the ceiling. Standard ...Operates at normal air flow. Mode 1 ...Air flow becomes greater than normal.
WIRELESS REMOTE CONTROLLER FEATURES 4 mode timer setup available (ON / OFF / PROGRAM / SLEEP). Four kinds of timers. Easy operation. Easy to change signal code (max. 4 units) by button operation. ...
Page 7
FUNCTIONS MODE button Selects the operating mode (AUTO, COOL, DRY, FAN, HEAT). /Start / end R.C. signal code change. (Max 4 types) 10°C HEAT button SET TEMP. button ( ▲ / ▼ ) Sets the indoor temp./ Sets R.C. signal code. ECONOMY button SLEEP button Pressed to select sleep timer.
DIMENSIONS MODEL : ABG30LRTE, ABG36LRTE (Unit : mm) Top view Side view Rear view Suspension bolt pitch 1,600 Dimensions (Space Required for Installation) INDOOR UNIT (Top view) Suspension bolt should extend INDOOR UNIT outward 30 to 75. Refrigerant piping flare connection (Gas) ...
Page 11
INSTALLATION PLACE (Unit : mm) Ceiling INDOOR UNIT 80 or more 150 or more Ceiling 10 or more Obstruction Floor Ceiling panel INDOOR UNIT Ceiling panel 80 or more 150 or more 10 or more Obstruction Floor - (01 - 08) -...
FAN PERFORMANCE 7-1. AIR VELOCITY DISTRIBUTION MODEL : ABG30LRTE Note: Condition Fan speed : High Unit : m/s Operation mode : FAN 0.25 Unit : m/s 10 11 12 13 14 15 16 17 TOP VIEW VERTICAL : UPWARD HORIZONTAL : CENTER 0.25 Unit : m/s...
Page 16
MODEL : ABG36LRTE Note: Condition Fan speed : High Unit : m/s Operation mode : FAN 0.25 Unit : m/s 10 11 12 13 14 15 16 17 TOP VIEW VERTICAL : UPWARD HORIZONTAL : CENTER 0.25 Unit : m/s 10 11 12 13 14 SIDE VIEW FLAP : CENTER...
7-2. AIRFLOW MODEL : ABG30LRTE COOLING Number of Fan speed rotations Airflow (r.p.m.) 1660 HIGH 1000 1500 1200 1000 QUIET HEATING Number of Fan speed rotations Airflow (r.p.m.) 1660 HIGH 1000 1500 1200 1000 QUIET - (01 - 14) -...
Page 18
MODEL : ABG36LRTE COOLING Number of Fan speed rotations Airflow (r.p.m.) 1900 HIGH 1100 1118 1500 1200 1000 QUIET HEATING Number of Fan speed rotations Airflow (r.p.m.) 1900 HIGH 1100 1118 1500 1200 1000 QUIET - (01 - 15) -...
ELECTRIC CHARACTERISTICS Model name AB G30LRTE AB G36LRTE Voltage 230 ~ Power supply Frequency Max. operating current (Indoor unit) Connection cable 1.5 - 2.5 *1) Wiring spec. Limited wiring length *1) Wiring spec. Selected Sample (Selected based on Japan Electrotechnical Standards and Committee E0005) - (01 - 19) -...
SAFETY DEVICES Model Protection form AB G30LRTE AB G36LRTE Circuit protection Current fuse (PCB) 250V 3.15A Thermal protection 135±15°C OFF Fan motor protection program 115±15°C ON - (01 - 20) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN102 Control input — See external CN103 — Operation status output input/output settings for details. — Fresh air control output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor Connected unit control PC board Connector Ex.)Relay unit Ex.)Display 24V DC Relay power supply *10 m Signal Field supply * Make the distance from the PC board to the connected unit within 10m.
Page 26
FRESH AIR CONTROL OUTPUT A signal linked to air conditioner indoor fan ON can be output. * However, signal becomes OFF during cold air prevention control operation. Circuit diagram example Indoor Connected unit control PC board Ex.) Fan Ex.) Relay unit 12 V Connector...
FUNCTION SETTINGS 12-1. INDOOR UNIT INDOOR UNIT DIP SW Remote controller address setting Jumper Wire Setting forbidden SWITCH POSITION MAIN PCB Indoor unit Printed circuit board DIP-SW SETTING Remote controller address setting A number of indoor units can be operated at the same time using a wired remote controller. Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
12-2. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings can cause the indoor unit malfunction. • After the power is turned on, perform the “FUNCTION SETTING” according to the installation conditions using the remote controller.
Page 29
CONTENTS OF FUNCTION SETTING • Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in accordance with the installed condition. After the power is turned on, perform the Function Setting on the remote control. •...
Page 30
5) Auto restart Enable or disable automatic system restart after a power outage. ( . . .Factory setting) Setting Description Function Number Setting Value * Auto restart is an emergency function such as for power failure etc. Do not start and stop the indoor unit by this function in normal operation. Be sure to operate by the control unit, or external input device.
Page 31
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) 1.
OPTIONAL PARTS 13-1. CONTROLLER Exterior Parts name Model No. Summary Large and full-dot liquid Wired remote crystal screen, wide and UTY-RVN M controller large keys easy to press, user-intuitive arrow key. Wired remote Unit control is performed by UTY-RNNM controller wired remote controller Simple...
13-2. OTHERS Exterior Parts name Model No. Summary Drain Pump Optional drain lift-up mechanism UTR-DPB24T unit allows more flexible installation. Round flange is used when the fresh air duct is installed. Round flange UTD-RF204 Round flange Use to connect with various External UTY-XWZX peripheral devices and air...
Page 34
2. OUTDOOR UNIT SINGLE TYPE : AOG30LETL AOG36LETL DTR_AO135E_01 2013.02.28...
SPECIFICATIONS Type INVERTER HEATPUMP Model name AO G30LETL AO G36LETL Power source 230V ~ 50Hz Available voltage range 198-264V ~ 50Hz Starting current 12.2 13.7 Cooling 3600 3800 Airflow rate Heating 3600 3800 Type × Q'ty Propeller × 1 Motor output Cooling Sound pressure level...
DIMENSIONS MODELS : AOG30LETL, AOG36LETL (Unit : mm) Top view Front view Side view Air flow Bottom view INSTALLATION PLACE When there are obstacles at the back When there are obstacles at the back, When there are obstacles at the back, or front sides.
ELECTRIC CHARACTERISTICS Model name AO G30LETL AO G36LETL Voltage 230 ~ Power supply Frequency *1) Max. operating current 17.0 20.0 Starting current 12.2 13.7 Main fuse (Circuit breaker) current *2) Wiring spec. Power cable *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring spec.
SAFETY DEVICES Model Protection form AO G30LETL AO G36LETL Current fuse (Near the terminal) 250V 25A Circuit protection Current fuse (Filter printed circuit board) 250V 10A Current fuse (Main printed circuit board) 250V 3.15A OFF : 140±20°C Fan motor protection Thermal protection program ON : 110±20°C OFF : 4.2±0.1MPa...