hit counter code
Download Print this page

LG LAU095HV Svc Manual page 51

General wall mounted-inverter type
Hide thumbs Also See for LAU095HV:

Advertisement

Part 4 Trouble Shooting
Error code
Description
Heat-sink Temp. is over
95°C(203°F)
4
Heat-sink TH.
is open or short
Check flow
Heat-sink TH is connected to
outdoor PCB assembly?
No
- Connect to CN-TH2 in
outdoor PCB assembly
9k,12kBtu/h Model Heat-sink Thermistor resistans check
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
• Heat-sink TH. is damaged(short or open).
• Heat-sink Temp. is over 95°C(203°F)
• Damage or defect on the sensing circuit of outdoor pcb assembly.
(R01H, R02H, C01H)
YES
Heat-sink TH. in INV-IC is
Right ?
No
Check heat-sink TH.
- Measure resistance of TH.
(about 10kΩ at 25°C(77°F))
120
100
80
60
40
20
0
20 30 40 50 60 70 80 90 100110 120 130
- 50 -
Cause of error
YES
Sensing circuit of outdoor
pcb is right ?
No
- Check soldering state of
R01H, R02H, C01H
R-T Graph
Temperature[˚C]
LGE Internal Use Only

Advertisement

loading