Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. LG LMDN095HV Owner's Manual Shop genuine replacement parts for LG LMDN095HV Find Your LG Air Conditioner Parts - Select From 2328 Models -------- Manual continues below --------...
Page 2
website http://www.lgservice.com Multi Type Air Conditioner OWNER'S MANUAL Type : Ceiling Concealed Duct - Low Static IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. • Please retain this owner's manual for future reference after reading it thoroughly.
Page 3
Multi Type Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS A. Safety Precautions ....3 B. Necessary functions before using ..6 Write the model and serial numbers here: Model # Trial Operation ......6 Serial # Celsius/Fahrenheit Switching..7 You can find them on a label on the side of each unit. Setting the Central-Control Dealer's Name Address........8...
Page 4
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
Page 5
Safety Precautions I Operation Do not let the air conditioner Take care to ensure that power Do not place anything on the run for a long time when the cable could not be pulled out or power cable. humidity is very high and a damaged during operation.
Page 6
Safety Precautions CAUTION I Installation Always check for gas (refrigerant) Install the drain hose to ensure Keep level even when installing leakage after installation or repair that water is drained away the product. of product. properly. • Low refrigerant levels may •...
Page 7
Necessary functions before using Necessary functions before using Trial Operation The trial operation is to check the installation status of the product. The temperature will not be controlled during trial operation. Instead the product will operate in several modes such as cooling, strong wind, comp-on. If you want to set the trial operation mode, press the mode button and the Fan speed button same time for three seconds.
Page 8
Necessary functions before using Celsius/Fahrenheit Switching If you want to change the temperature unit as the Celsius or Fahrenheit, press the Temperature control button( ) and the Fan speed button same time for three seconds to enter the setting Mode. PQRCUCS0C Defrost Preheat Out door...
Page 9
Necessary functions before using Setting the Central-Control Address Please set the address while using the central controller. You don't need to set address if you don't use central controller. If you want to set the address on the display panel, press both temperature control buttons (L/M) same time for three seconds.
Page 10
Necessary functions before using ESP Function E.S.P function is setting the volume of each fan speed. It is for the convenience of installation. It is recommended that you should not use this function while using the remote controller. Press the mode button and the temperature increasing button(L) same time for three seconds.
Page 11
Operating Instructions Operating Instructions Simple Wired Remote Controller PQRCUCA0 Defrost Preheat Out door Room Temp Total on Central Run Cooling Heating Auto Dry Fan MODE SPEED Each function will be shown on the display panel for three second or so when the power is applied at first. 1.
Page 12
Operating Instructions Cooling Operation Cooling operation will begin if you press the On/Off button. ❈ Plasma function is always operating for working if product has plasma function. Press the temperature button and set the desired temperature lower than the current room temperature.
Page 13
Operating Instructions Heating Operation If you want to set the heating operation, press the On/Off button. And press the mode button. ❈ Plasma function is always operating for working if product has plasma function. Set the desired room temperature higher than the current room temperature.
Page 14
Operating Instructions Auto-Operation Set the operation mode to auto-operation after pressing the On/Off button. ❈ Plasma function is always operating for working if product has plasma function. PQRCUCA0 Out door When the room temperature is lower than the desired temperature: Heating Operation starts [For Heat Pump Models only] Auto When the room temperature is higher than the desired...
Page 15
Operating Instructions Dry(Dehumidification) Operation Dry(Dehumidification) by lowering temperature slightly Press the On/Off button on the remote controller. ❈ Plasma function is always operating for working if product has plasma function. Set the mode to dry operation by pressing the mode button.
Page 16
Operating Instructions Fan Speed Selection You can easily control the fan speed. Select the proper fan speed which you want by pressing the fan speed button on the remote controller. • If you press the fan button, the speed of the fan will change in the order of Low>Medium>Hi>Power.
Page 17
Operating Instructions Indoor Temperature Display When the fan speedbutton is pressed on the remote controller for about 3 seconds, the indoor temperature PQRCUCA0 will be displayed for about 5 seconds, then goes back Defrost Preheat Out door to the previous screen. Room Temp Total on •...
Page 18
Operating Instructions Child Lock This is a function to prevent tampering of settings by children or others. You can use the child lock function by pressing both temperature increasing button and fan speed button for three seconds. In the initial setting of the child lock PQRCUCA0 Defrost Preheat...
Page 19
Maintenance and Service Maintenance and Service CAUTION: Before performing any maintenance, turn off the main power to the system. ❏ Never use any of the followings: Grille, Case, and Remote Control • Water hotter than 40°C(104°F) ❏ Turn the system off before cleaning. To clean, wipe with Could cause deformation and/or discoloration.
Page 20
Maintenance and Service When the air conditioner is not going to be used for a long time. When the air conditioner is to When it is not going to be used for be used again. a long time. I Check that the air inlet and outlet of the Operate the air conditioner on Air indoor/outdoor unit are not blocked.
Page 21
Before you call for service... Before you call for service... Troubleshooting Tips! Save time and money! Check the following points before requesting repairs or service..If the malfunction persist, please contact your dealer. The air conditioner The room has a It seems that Air conditioner does does not operate.