Managing the Disk Array Using Array Manager 60

Note
Task
Capacity Management
Binding a LUN
Unbinding a LUN
Calculating LUN Capacity
Adding a Global Hot Spare
Removing a Global Hot Spare
Identifying Disks
Changing LUN Ownership
1
Reviving a LUN
Replacing a LUN
296
Command
amcfg -L <cntrlrID>:<LUN> -d <channel:ID>,<channel:ID>.....
-r <RAIDlevel> <options> <ArrayID>
amcfg -D <LUN> [-force] <ArrayID>
amcfg -C -d channel:ID,channel:ID...
-r <RAIDlevel> -s <stripe> <ArrayID>
ammgr -h channel:ID <ArrayID>
ammgr -d channel:ID <ArrayID>
amdsp -d <ArrayID>
amcfg -M <LUN> -c <cntrlrID> <ArrayID>
amutil -L <LUN> <ArrayID>
amcfg -R <cntrlrID>:<LUN> -d <channel:ID>,<channel:ID>.....
-r <RAIDlevel> <options> <ArrayID>