Advertisement

are tag numbers. You need tag numbers for the path setup. To determine the tag number, use the
devserv command with the rcd (read configuration data) parameter.

Attaching FICON/zHPF CHAs

You can attach the storage system to a host system using FICON adapters. The storage system can
be configured with up to 112 FICON physical channel interfaces.
FICON/zHPF uses a mapping layer technique based on Fibre Channel and multiplexing technologies
to improve data-transfer rates, reduce the number of channel connections, and support greater distances
between storage systems and mainframe hosts. FICON and FICON/zHPF have identical hardware
specifications, but FICON/zHPF offers improved performance.
By supporting full-duplex data transfers and allowing greater throughput rates over longer distances
than ESCON, FICON/zHPF delivers faster data access, higher transaction rates, higher data movement
speeds between mainframe servers and storage devices. Infrastructure management is simplified, and
allows geographically dispersed data centers for optimal business continuity. This simplifies data
center operations and reduces hardware and storage management costs.
In summary, FICON/zHPF provides the following key features:
Full-duplex bi-directional data transfers
Multiple I/O processes
Allows small and large data transfers to be transmitted at the same time
High-bandwidth transfer (up to 4 Gbps)
Greater throughput rates over longer distances than ESCON
Lowered interlock between the disk controller and channel
Executing pipeline CCW
Use of FCP as the fibre-channel link transport for zHPF

FICON/zHPF physical specifications

The following table compares the physical specifications between ESCON and FICON/zHPF.
Table 4 Comparing ESCON and FICON/zHPF physical specifications
Item
Physical Interface
Logical Interface
Bandwidth and Direction
Cable
Distance
Long wave
14
FICON/zHPF and ESCON host attachment
ESCON
ESCON
ESCON
200 Mbps
Unidirectional
Multi Mode/62.5um
FICON/zHPF
ANSI FC-PH/PC-PI-2 etc. For details, see ANSI
standard Fibre Channel Single-Byte Command Code
Sets Mapping Protocol
4.
ANSI FC-SB-2/FC-SB-3/FC-SB-4
1 Gbps / 2 Gbps / 4 Gbps
Bidirectional
Single Mode/9um
Multi Mode/50 or 62.5um
Single Mode/9um
10 km, 20 km (with RPQ)