. . . food has frozen together.
^ Use a blunt instrument, e.g. a spoon
handle or plastic scraper, to prise it
apart carefully.
. . . there is a thick layer of ice in the
freezer compartment.
^ Check whether the freezer
compartment door closes properly.
^ Defrost and then clean the freezer
compartment.
Too thick a layer of ice reduces
efficiency and increases energy
consumption.
. . . the interior light in the refrigerator
section is not working.
^ Has the contact switch become
stuck?
^ Make sure that the temperature
selector is not pointing to the "0"
position.
If it is not pointing to the "0" position,
the lamp is defective:
^ Disconnect the appliance from the
mains. Switch off at the wall and
withdraw the plug from the socket, or
disconnect the mains fuse or remove
the screw-out fuse in countries where
this is applicable.
Problem solving guide
^ Reach into the back of the light cover,
press upwards at the side a, and
then pull the cover off b.
^ Replace the lamp.
Lamp specification:
220 - 240 V, max. 15 W, E 14 fitting.
^ Push the cover securely back into
position.
. . . the floor of the refrigerator
section is wet.
The drain hole is blocked.
^ Clean the condensate channel and
drain hole.
If you still cannot remedy the fault
having followed these suggestions,
please contact the Miele Service
Department.
To prevent unnecessary loss of
temperature it is advisable not to
open the doors while waiting for the
appliance to be serviced.