Observing (Capturing) the Y
Observing (Capturing) the Y
Set must be in "WHITE WASH" All other DC Voltage adjustments should have already been made.
Fig 1:
As an example of how to lock in to the Y-Drive
Waveform. Fig 1 shows the signal locked in at 4ms
per/div. Note the 2 blanking sections.
The signal for SET-DN is outlined within the Waveform
Fig 2:
At 2mSec per/division, the waveform to use for
is now becoming clear.
SET-DN
Fig 3:
At 400us per/div. the signal for
recognize. It is outlined within the Waveform
Fig 4:
At 40uSec per/division, the adjustment for
can be made.
-
Drive Signal for
-
Drive Signal for
is now easier to
SET-DN
SET-DN
51
Vsetup
Ramp
-
Down
Vsetup
Ramp
-
Down
Outlined
Area
Area to
be adjusted
Blanking
Area to
be adjusted
Area to
be adjusted
Preliminary Information 42PQ30
Blanking
Blanking
FIG1
4mS
FIG2
2mS
FIG3
400uS
FIG4
40uS