Jet table
Conversion to another type of gas
,
Connection to the gas supply, or conversion from one
type of gas to another, should only be undertaken by an
approved and registered gas installer in strict accordance
with local and national safety and building regulations.
When converting to a different type of gas, all burner jets
have to be changed.
Burners
NG
Small burner
Medium burner
Large burner
Wok
ULPG
Small burner
Medium burner
Large burner
Wok
The jet markings refer to 1/100 mm of the jet diameter.
Main jet(s) Ø
0.90
1.10
1.43
2x 1.27 / 0.90
0.52
0.66
0.81
2x 0.70 / 0.46
Small jet(s) Ø
0.52
0.52
0.60
0.44
0.23
0.36
0.44
0.25
49