Page 1
Operating and installation instructions Cooker hood To prevent the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time. en-GB M.-Nr. 10 093 490...
Contents Warning and Safety instructions ................3 Caring for the environment ................. 12 Modes of operation....................13 Guide to the appliance..................14 Operation ......................16 Switching the fan on ....................16 Selecting the power level..................16 Switching the fan off ....................17 Switching the hob lighting on / off .................
They contain important notes on the safety, installation, use and maintenance of the appliance. Miele cannot be held liable for non-compliance with these instructions. Keep these instructions in a safe place and ensure that all users are familiar with the contents.
Page 4
Warning and Safety instructions The cooker hood can only be used by people with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if they are supervised whilst using it, or have been shown how to use it in a safe way and recognise and understand the consequences of incorrect operation.
Unauthorised installation, maintenance and repairs can cause considerable danger for the user. Installation, maintenance and repairs must only be carried out by a Miele authorised technician. A damaged appliance can be dangerous. Check it for visible signs of damage. Do not use a damaged appliance.
Page 6
Miele spare parts. If the electrical connection cable is faulty it must only be replaced by a Miele authorised service technician to protect the user from danger. During installation, maintenance and repair work, the appliance...
Page 7
Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room Warning - danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room.
Page 8
Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the cooker hood and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
Warning and Safety instructions Correct use Never use a naked flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over a naked flame. When switched on, the cooker hood could draw flames into the filter. Fat deposits could ignite, presenting a fire hazard.
Warning and Safety instructions Do not use the cooker hood without the filters in place. This way you will avoid the risk of grease and dirt getting into the appliance and hindering its smooth operation. The filters should be regularly cleaned or changed as appropriate. Saturated filters are a fire hazard.
Page 11
Warning and Safety instructions Exhaust ducting must be of non-inflammable material. Suitable material is available from Miele specialist dealers or the Miele Spares Dept. The appliance must not be connected to a chimney or flue which is in use. Neither should it be connected to ducting which ventilates rooms with fireplaces.
Caring for the environment Disposal of the packing Disposal of your old appliance material Electrical and electronic appliances often contain valuable materials. They The packaging is designed to protect also contain materials which, if handled the appliance from damage during or disposed of incorrectly, could be transportation.
Modes of operation Depending on the model of the cooker Recirculation mode hood, the following options are (recirculation mode cooker hoods available: require a conversion kit and charcoal filter (available as optional accessories): Extraction mode see "Technical Data") The air is drawn in and cleaned by the The air is drawn in and cleaned first by grease filters and directed outside.
Page 15
Guide to the appliance a Telescopic extension piece b Tower c Canopy d Controls e Grease filter(s) * f Recirculation grilles (only for recirculation mode) g Hob lighting h Charcoal filter (special accessory for recirculation mode) i On/Off control for the fan j Controls to select the fan power level k On/Off control for the hob lighting *Your cooker hood is supplied with one or more grease filters depending on...
Operation Switching the fan on Automatic switch-off of the Intensive setting Press the On/Off control . You can set the Intensive setting so that The fan will switch on at level 2. The it only runs for 10 minutes before symbol and 2 will light up in the power reverting automatically to level 3.
Operation Switching the fan off Use the On/Off control to switch the fan off. The symbol will go out. Switching the hob lighting on / The hob lighting can be switched on and off independently of the fan. ...
Energy saving tips This cooker hood operates very efficiently and economically. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. In extraction mode, if there is insufficient air flow the cooker hood cannot operate efficiently and this causes increased operating...
All external surfaces and controls can proprietary conditioning agent for be cleaned using hot water with a stainless steel (available from Miele) small amount of washing-up liquid can also be used. Follow the applied with a well wrung-out soft manufacturer’s instructions on the...
Cleaning and care Important for the controls Grease filters The re-usable metal grease filters in the Do not leave soiling on the controls appliance remove solid particles for any length of time. (grease, dust, etc.) from the kitchen Otherwise they may suffer vapours, preventing soiling of the discolouration or damage.
Page 21
Cleaning and care Cleaning the grease filters by hand After cleaning Clean the filters with a soft nylon After cleaning, leave the filters to dry brush in a mild solution of hot water on an absorbent surface before and a small amount of washing-up replacing them.
Disposing of the charcoal filter Replacement charcoal filters can be Used charcoal filters can be disposed obtained from your Miele retailer or via of with the normal household waste. the internet at www.miele-shop.com. See "Technical data" for type and reference number.
Installation Before installation Dismantling Should the appliance ever need to be Before installation, it is important dismantled, follow the installation to read the information given on the instructions in reverse order as following pages as well as the described on the installation sheet. A "Warning and Safety instructions"...
Page 25
Installation a 3 protective sheets for use when fitting the tower b 1 exhaust connection 8 screws, 5 x 60 mm and for exhaust ducting 150 mm 8 plugs, 8 x 50 mm c 1 reducing collar for securing to the wall. for exhaust ducting ...
Installation a Extraction b Recirculation c Ventilation grille positioned at the top for recirculation de (Only d is required for recirculation mode cooker hoods). The shaded area represents the wall or ceiling area for the ducting cut-out and for the connection socket.
Installation Installation recommendations Drilling diagram for wall mounting – When deciding on the safety distance between the hob and Please follow the directions given in cooker hood, please note that a the installation instructions supplied distance of 650 mm above electric for drilling.
Connection for air extraction If the exhaust is ducted through an If this cooker hood is used at the outside wall, a telescopic wall vent or same time as a heating appliance a roof vent (available as an optional that relies on oxygen from the same accessory) is recommended.
Connection for air extraction Condensate trap Silencer To achieve even further reductions in noise levels, a special silencer (optional accessory) can be fitted in the ducting system. In addition to insulating the exhaust ducting, we recommend that a suitable Extraction mode condensate trap is also installed to collect and evaporate any condensate which may occur.
Page 31
Connection for air extraction Recirculation mode The silencer needs to be positioned between the exhaust socket and the directional unit . Ensure there is adequate space for fitting it.
Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national and For extra safety it is advisable to protect local safety regulations (BS 7671 in the appliance with a suitable residual...
Miele dealer or the Miele Service Department. Contact details for Miele are given at the back of this manual. N.B. A call-out charge will be applied to service visits where the problem could have been resolved as described in these instructions.
209 W Voltage, frequency AC 230 V, 50 Hz Fuse rating Mains connection cable length 1.5 m Weight DA 416-7 21 kg DA 419-7 25 kg Recirculation mode with conversion kit DUW 20 and charcoal filter DKF 12-1 (optional accessories)
Technical data Data sheet for domestic cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No. 66/2014 MIELE Model name / identifier DA 416-7 Annual Energy Consumption (AEC 69,2 kWh/year hood Energy efficiency class A+ (most efficient) to F (least efficient)
Page 36
Data sheet for domestic cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No. 66/2014 MIELE Model name / identifier DA 419-7 Annual Energy Consumption (AEC 69,2 kWh/year hood Energy efficiency class A+ (most efficient) to F (least efficient)