IMPORTANT: SAVE FOR THE LOCAL ELECTRICAL INSPECTOR'S USE Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information. KM 2355 G To prevent accidents and appliance damage read these instructions before installation or use.
Page 2
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS Installation The power cord and a flexible gas connection line must be attached in The minimum distances given in such a way that they are not in contact these Installation instructions are to with moving parts of kitchen elements (e.g.
Page 3
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS Safety distances above the If there are several appliances appliance beneath a hood, and they have different minimum safety distances always observe the greatest distance. The minimum safety distance given by the hood manufacturer must be maintained between the cooktop and the hood above it.
Page 4
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS Safety distances When installing a gas cooktop, there may be cupboard or room walls of any size on the rear side and on one side (right or left) (see illustrations). The following minimum safety distances must be maintained: Not allowed a 2"...
Installation dimensions a Appliance front Please take careful note of the detailed diagrams for the cut-out b Installation height dimensions in granite and marble c Gas connection countertops. dPower supply box with connection cable, L = 4 ft (1.2 m) e Stepped cut-out for granite or marble worktops...
Installation The cooktop may be installed: Flush mounted gas cooktops are – in a suitable cut-out in a granite or only suitable for installation in marble countertop. granite, marble, tiled or solid wood – in a suitable cut-out in a tiled or solid countertops.
Page 7
Installation ^ Make the countertop cut-out as Granite and marble countertops shown in "Installation dimensions". Remember to maintain the minimum safety distances (see "IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"). ^ Feed the power cord down through the cut-out. ^ Center the cooktop b in the cut-out. ^ Connect the cooktop to the mains (see "Electrical connection").
Page 8
Installation ^ Make the countertop cut-out as Solid wood and tiled worktops shown in "Building-in dimensions". Remember to maintain the minimum safety distances (see "IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"). ^ Fix the wooden frame d 1/16" (2 mm) below the top edge of the countertop (see diagram).
Securing the appliance After installation Secure the appliance as shown, using the fixing brackets supplied. Check that all the burners are operating correctly. 3/4" (20 mm) countertop The flame must not go out on the lowest setting, or when the control is turned quickly from a high to a low setting.
Electrical connection This appliance must be grounded This appliance is equipped with a according to local or national codes. three-prong grounding plug to prevent shock hazards. It should be All electrical work should be plugged directly into a properly performed by a qualified electrician grounded outlet.
Page 11
Electrical connection Wiring diagram Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Gas connection Installation and service must be The gas connection must be made performed by a qualified installer, in accordance with local codes or, service agency or gas supplier. in the absence of local codes, with In Massachusetts installation must the National Fuel Gas Code, be performed by a licensed ANSI Z 21.1 / NFPA 54...
Page 13
- 4" w.c. LP gas - 10" w.c. Do not use any regulator unless it has been supplied by Miele. Doing so may cause a gas leak. If there is any doubt concerning installation contact the Miele Technical Service Department.
If the appliance is to be connected to a type of gas other than it was originally configured for, both the regulator and burners must be converted. A conversion kit is available as an optional accessory from the Miele Technical Service Department.
Burner performance Rated load at high setting Burner Type of gas KM 2355 BTU/hr Auxiliary burner Natural gas (NG) 3,900 1.14 Liquid gas (LP) 3,000 0.88 Normal burner Natural gas (NG) 5,900 1.73 Liquid gas (LP) 6,000 1.76 High-speed Natural gas (NG) 9,800 2.87 burner...
Help protect our environment Disposal of packing materials Disposal of an old appliance The cardboard box and packing Old appliances contain materials that materials are biodegradable and can be recycled. Please contact your recyclable. Please recycle. local recycling authority about the possibility of recycling these materials.