Installation Instructions Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information. KF1803 SF, KF1813 SF, KF1903 SF, KF1913 SF To prevent accidents and machine damage read these instructions before installation or use.
Caring for the environment Disposing of the packaging Disposal of your old appliance materials Old appliances may contain materials that can be recycled. Please contract The packaging is designed to protect your local recycling authority about the the appliance from damage during possibility of recycling these materials.
Installation Installation site Have the appliance installed by a The appliance should be installed in a qualified technician, according to dry, well-ventilated room. the enclosed installation instructions. Do not install the appliance: - outdoors - in an environment with dripping WARNING water This appliance is top-heavy and...
Page 4
Installation Important! When there is high humidity a build-up of condensation on the outer surfaces of the appliance can occur.This can cause the surfaces to corrode.To prevent this, it is advisable to install the appliance in a dry and/or an air-conditioned room with sufficient ventilation.Please ensure that doors close and seal properly after...
See "Niche dimensions". If in doubt, contact Miele. The side walls of the installation cavity Furniture/fixtures must be plumb. The new appliance will be mounted...
The "Merging Kit" is available from Miele. There are many different installation options. You are limited only by the Contact Miele or your dealer for design of the kitchen. specific information about which combinations will work with your The door hinge cannot be appliance.
The "Merging Kit" will also be needed. The "Merging Kit" is available from Miele. Installation with partition without using the "Merging Kit" If there is a partition with a thickness of more than 6 "...
Page 8
Installation Adjusting the door opening angle (optional accessory) Depending on the installation site, it may be necessary to adjust the door opening angle to 90°. ^ Open the door. ^ Insert the banking pin through the holes and drive in with a hammer. The door opening angle is now limited to 90°.
Page 9
Dimensions Door dimensions (opening angle 90°) KF 18X3 SF " (829 mm) KF 19X3 SF " (982 mm) Door dimensions (opening angle 115°) KF 18X3 SF 32 " (829 mm) " (363 mm) KF 19X3 SF 38 " (982 mm) 16 "...
Page 11
Dimensions Power supply and water connection 1. Power supply 2. Water connection KF 18X3 SF 15" (381 mm) KF 19X3 SF 18" (458 mm) Install a pressure limiting device and water hammer arrester for inlet water pressures exceeding 80 psi.(Refer to Uniform Plumbing Code, Sections 608.2 and 609.10) Never install or operate where inlet water pressure may exceed 120 psi.
Installing the appliance Before you begin – Adhesive tape – Multi-grip pliers Read these instructions completely and carefully. – Level Have the appliance installed by a – Tape measure qualified technician, according to – Square the enclosed installation instructions. When fastening the cabinet to the wall behind it (see "Installing the appliance") use: To reduce the risk of injury or...
Installing the appliance Aligning the housing unit Check the installation niche To ensure a safe, trouble-free installation and the best possible cosmetic result, check to be sure that the installation space complies with the installation requirements. ^ Check the base (see "Installation"). ^ Check the dimensions of the cavity.
Installing the appliance RemoteVision module There are transportation safety installation devices inside the appliance to (optional accessory) protect the shelves and storage compartments until installation is Always disconnect the appliance complete. Do not remove them, or from the power supply when parts may be damaged.
In that case, repeat the Keep the appliance door closed process. If that does not correct the until it is securely fastened in the problem, contact Miele. niche. Tipping hazard. Because of the size and weight of the appliance, it is essential to...
Installing the appliance Mounting Accessories The mounting accessories needed for installing the appliance into the niche are included in the packaging. Several plastic bags are included which are numbered alphabetically. The bag needed for each step will be Two anti-tip brackets are marked with its respective letter.
Page 17
Installing the appliance In a cabinet without a back wall ^ Now attach the installation niche to the wall. The built-in cabinet must be secured to the wall behind it with several screws. In a cabinet with a back wall ^ screw the cabinet to the wall behind it in several places using suitable mounting brackets.
Page 18
Installing the appliance Securing an alternative anti-tip – If the installation niche is deeper than the appliance, select a beam with a device larger cross section, or attach two If the anti-tip brackets cannot be beams. attached securely, an alternative anti-tip device can be used.
Installing the appliance Sliding the appliance into the installation niche If a side-by-side installation is desired, connect the two appliances together. See the Installation Manual included with the "Merging Kit". ^ Open the bottom door. ^ To protect the corners of the installation space, attach edge protectors where needed (not included).
Page 20
Installing the appliance ^ To prevent the power cord from becoming caught: Tie a piece of string to the middle of the power cord and feed it forward under the appliance. When sliding the appliance in, pull the cable forward b. ^ Carefully slide the appliance into the space.
Installing the appliance ^ Unscrew the height-adjustable feet Aligning the appliance until the mark on the base has ^ Align the appliance with the custom reached the indicated guide front. dimension 1 1/4" (32 mm). The guide dimension of 1 1/4" (32 mm) is related to a niche height of 84"...
Page 22
Installing the appliance Attaching the appliance to the installation niche ^ Open the appliance doors. ^ Open the lower appliance door and hand the stainless steel cover on the double-threaded bolts. ^ Screw the nuts onto the double-threaded bolts. ^ Replace the cover strip. ^ Fasten the appliance on the left and right hand sides with the 3 (supplied) wood screws.
Page 23
Installing the appliance Attaching the toe-kick cover The maximum height of the toe-kick cover is 4" (101 mm) from the top of the floor. Do not cover the ventilation slits in the plinth. Risk of damage to the appliance. ^ If required, cut the toe-kick cover to the required length and height.
Page 24
Installing the appliance Mounting the air separator The air separator keeps the supply and exhaust air separate. This prevents warm exhaust air from flowing into the machine, optimizing the energy performance of the unit. ^ If necessary, shorten the three parts of the air separator.
Page 25
Do not use pipe extenders. Turn off the water supply before In the event that the piping has to be connecting the water lines to the ice replaced only Original Miele Spare cube maker. parts are suitable for use. Contact Miele.
Plumbing Preparing the water connection For appliances with a hose guide The connection to the household water supply must be installed before the appliance is installed. ^ Turn off the main water valve to prevent damage caused by leaking water. ^ Attach the connecting pipe to the shut-off valve, according to the instructions supplied by the...
Plumbing ^ Push the union nut and seal onto the Connecting the water supply water pipe. When connecting the water pipe to ^ Push the end of the water pipe into the solenoid valve of the appliance, the appliance connection and screw follow the instructions supplied by on the union nut, 3.
If there are any questions regarding the electrical connection of this appliance to the power supply, please consult a licensed electrician or call the Miele Technical Service. U1-800-999-1360 V1-800-565-6435...
'virtual link' between your following requirements appliance and our monitoring center. If – A wireless router that supports an a fault occurs, Miele's client service IEEE 802.11b/g protocol center will be notified and contact you, ® or another trusted individual identified –...
RemoteVision (optional accessory) ^ Tap the X button until ; appears in Accessing the RemoteVision the display. control panel ^ Touch the access button "p" to confirm. See the table on the following page for a description of each setting in the ^ Touch the access button "p"...
Page 31
RemoteVision (optional accessory) MasterCool control panel options for RemoteVision Status indicators Description of function Flashing ; ~ Module booting phase Flashing ; ‡ Not connected to network Flashing ; | Connection to network established, no IP address assigned Solid Connected to network Flashing ;...
Page 33
KF 1803 SF KF 1813 SF KF 1903 SF KF 1913 SF en - US, CA M.-Nr. 09 920 880 / 00...