3N AC 380 - 415 Frequency 50 – 60 Rated load Fuse rating 3 × 16 Connection cable, min. cross-section mm² 4 ×2.5 Connection cable (not supplied) Technisches Datenblatt / Technical datasheet: PW 6137 EL Datum / Date: 12.10.2011 Seite / Page: 8...
Page 9
Connection cable, min. cross-section mm² 5 × 1.5 Connection cable (not supplied) Miele recommends the use of a flexible supply lead and an additional cut-off switch. The switch should be visible and accessible after installation. Technisches Datenblatt / Technical datasheet: PW 6137 EL Datum / Date: 12.10.2011...
Page 10
Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no. 05238090. Drain manifolds serving several machines must be of sufficient cross-section. Technisches Datenblatt / Technical datasheet: PW 6137 EL Datum / Date: 12.10.2011 Seite / Page: 10...
Page 11
Installation must comply with local requirements and cater for on-site conditions. The machine is supplied without feet to allow the interior thread to be used with stay bolts. Technisches Datenblatt / Technical datasheet: PW 6137 EL Datum / Date: 12.10.2011 Seite / Page: 11...
Page 12
Installation should only be carried out by authorised fitters in accordance with valid regulations! Observe installation instructions when installing machine! All rights reserved! Dimensions in mm Technisches Datenblatt / Technical datasheet: PW 6137 EL Datum / Date: 12.10.2011 Seite / Page: 12...