2. Standard voltage (convertible) 3 AC 208V Frequency Rated load 14.3 kW Fuse rating 3 × 50 Connection cable, min. cross-section 4 AWG 6 4 x 10 mm² (Connection cable not included) Technical datasheet: PW 6137 EL (electric) Date: 03.2015 Page: 11...
Page 12
59 1/16“ Length of inlet hose 1500 mm Hourly water demand (average for 60°C cotton program) Approx. 15.5 Approx. 55 l/h determined at cold, hot and hard water connection) gal/h Technical datasheet: PW 6137 EL (electric) Date: 03.2015 Page: 12...
Page 13
Drain connection on site (int. diameter) 75 mm [DN 70] Max. transient throughput 52.9 gal/min 200 l/min Vented drainage required. If ventilation is insufficient, fit Miele kit, Mat. no. 05238090. Drain manifolds serving several machines must be of suffi- cient cross-section. Fittings...
2. Tension (convertible) 3 AC 208V Fréquence Puissance de raccordement 14.3 Fusible 3 × 50 Câble d’alimentation, section minimum 4 x AWG 6 4 x 10 mm² (Câble d’alimentation non fourni) Plan d’installation : PW 6137 EL (électrique) Date: 03.2015 Page: 14...
Page 15
1500 mm Consommation d’eau par heure moyenne pour un programme Env. 15.5 gal/h env. 55 l/min standard (Couleurs 60°C) déterminée pour les raccordements eau froide, eau froide et eau dure Plan d’installation : PW 6137 EL (électrique) Date: 03.2015 Page: 15...
Page 16
½ x 2 3/8 po 12 x 60 mm L’installation et le montage de l’appareil et du socle doivent être effectués en conformité avec les notices de montage fournies. Plan d’installation : PW 6137 EL (électrique) Date: 03.2015 Page: 16...
Page 17
L’installation doit exclusivement être effectuée par des installateurs agréés, conformément aux prescriptions et aux règlements applicables et aux règlements de prévention des accidents. Veuillez impérativement vous conformer à la notice de montage lors de l’installation de l’appareil. Sous réserve de modifications! Plan d’installation : PW 6137 EL (électrique) Date: 03.2015 Page: 17...