1. INTRODUCTION 1.1 Purpose This manual provides information necessary to repair, description and download the features of this model. 1.2 Regulatory Information A. Security Toll fraud, the unauthorized use of telecommunications system by an unauthorized part(for example , persons other than your company’s employees, agents, subcontractors, or person working on your company’s behalf) can result in substantial additional charges for your telecommunications services.
Page 4
E. Notice of Radiated Emissions This model complies with rules regarding radiation and radio frequency emission as defined by local regulatory agencies. In accordance with these agencies, you may be required to provide information such as the following to the end user. F.
2. PERFORMANCE 2.1 H/W Features Solution EGOLD Voice v2 (ULC2+) Infineon Type Slide type Antenna Type Internal (dual-Band) Main Display 2.0” 128x160 TFT/65k 900 MHz/class 4 (2W) Dual Band (900/1800) Frequency 1800 MHz/class 1 (1W) Dual Band (900/1800) The physical dimension is [Length x Width x Thickness mm] Target:103x47x15.5mm Physical...
2.2 S/W Features Feature Detail Item Description Operating System Audio Speech Code FR,EFR,HR,AMR-NB AMR code GSM Full Rate 3GPP Adaptive Multi Rate (AMR-NB) FM Radio MP3 Ring Tone MP3 decode Integrated hands free Speaker phone mode speaker Key Tone 6 Level (Include Mute) Volume Ring Tone 6 Level (Include Mute)
Page 7
Quick Access Profile/ SMS + Voice Mail Mode In Idle Dimming Clock Dual Clock Home shortcut Display Shortcut icon in Idle Call History Last Dial Max : 20 records Number Last Received Max : 20 records Number Last Missed Max : 20 records Number Scratch Pad Memory...
Page 8
Cell Broadcast Read Cell Broadcast On/Off setting Receive On/Off Alert setting Language setting Topics Setting Contacts(Pho Entry ne Book) Field Name, Mobile, Home, Office Copy ME <-> SIM Move ME <-> SIM Email Entry Picture ID Video Caller ID vCard Business Card Delete Delete, Delete All(SIM or Phone),...
Page 9
Conference Up to 5 Call Plug in Type 3V & 1.8 V SIM Lock Service Provider / Network Lock SIM Toolkit Class 3 Short Read Message Message Write and Edit Message Send and Receive Message Reply to Message Forward Message Extract Number from Message Message...
Page 10
Miscellaneous Development & Test Function Facility Field Test Facility Display Software Version IMEI Restore Factory Setting Battery Charging Mode Text Input Language Selectable Auto Language Predictive word input Scheduler Calendar MAX: 20 records (18 chars) To Do Memo MAX: 10 records (80 chars) World Time Setting Local Time...
Page 11
Keypad Lock Real Time 12/24 Hour Clock Calendar Time Zone Daylight saving Alarm Manager Dimming Clock Power-off Alarm On Alarm Event Others Mobile Tracking For India, Asia software M-DOG For China Accessory microSD Adapter Mono earmic (without hook switch)
3. TECHNICAL BRIEF 3.1 Digital Main Processor Figure.3-1 PMB7890 FUNCTIONAL BLOCK DIAGRAM...
Page 13
3.1.1 Overview of X-GOLDTM102 The X-GOLDTM102 is a GSM baseband modem including RF transceiver covering the low bands GSM850 / GSM900 and high bands GSM1800 / GSM1900 bands. X-GOLDTM102 is Dual Band, therefore, it supports by default a low / high pair of bands at the same time: 1.
Page 14
– PWM source to drive vibrator – Keypad and display backlight supported. – HASH Unit support for hashing. Receiver • Constant gain, direct conversion receiver with fully integrated blocking filter • Two integrated LNAs • No need of interstage and IF filter •...
Page 15
3.1.3 System Platform Application X-GOLDTM102 was developed for very low cost Dual Band GSM/GPRS system solutions. Here are some potential System Platform configurations that can be built with X-GOLDTM102 Solution: 3.1.4 GSM System Description The X-GOLDTM102 is suited for mobile stations operating in the GSM850/900/1800/1900 bands. In the receiver path the antenna input signal is converted to the baseband, filtered, and then amplified to target level by the RF transceiver chip set.
Page 16
For baseband operation, the X-GOLDTM102 supports: • High Speed Circuit Switched Data (HSCSD) class 4 • Packet-oriented data (GPRS) class 4 with a coding scheme from 1 to 4. It provides fixed, dynamic, and extended dynamic modes. If the X-GOLDTM102 is only used as a modem, then it supports: •...
Page 17
C166 Debug Concept The debugging of the C166 uses the OCDS and the Cerberus. The X-GOLDTM102 also inlcudes a Real Time Trace module for software debugging. TEAKLite Debug Concept TEAKlite debugging uses the OCEM and the SEIB. 3.1.9 Power Management The X-GOLDTM102 provides the power management unit (PMU) for the complete mobile phone application.
Page 18
• Flash tied to the individual chip via an ID using e-fuses, that is, each X-GOLDTM102 chip has its own fused ID. • Harware support of SHA1 algorithm to reduce the booting time. Further details on the X-GOLDTM102 security concept are not publicly documented. GSM Cipher Unit This unit on the TEAKlite bus calculates the GSM/EDGE encryption keystream and the GSM/EDGE decryption...
3.2 Memory chip (S71GL064NA0BFW0Z0) Figure.3-2 S71GL064NA0BFW020 FUNCTIONAL BLOCK DIAGRAM Features _ Power supply voltage of 2.7 to 3.1V _ 100 ns access time (S71GL128N) _ 105 ns access time (S71GL512N) _ 25 ns page read times _ Packages: – 12.0 x 9.0 mm x 1.2 mm FBGA (TLD084) (S71GL512N) –...
3.3 Power Amplifier Module ( SKY77518 ) Figure.3-3 SKY77518 FUNCTIONAL BLOCK DIAGRAM The SKY77518 is a transmit and receive front-end module (FEM) with Integrated Power Amplifier Control (iPAC™) for dual-band cellular handsets comprising GSM900 and DCS1800 operation. Designed in a low profile, compact form factor, the SKY77518 offers a complete Transmit VCO-to- Antenna and Antenna-to-Receive SAW filter solution.
3.4 RF SAW (B9308) Application Low-loss 2in1 RF filter for mobile telephone GSM 900 and GSM 1800 systems, receive path (Rx) Usable passband: Filter 1 (GSM 1800): 75 MHz Filter 2 (GSM 900): 35 MHz Unbalanced to balanced operation for both filters Very low insertion attenuation Low amplitute ripple Impedance transformation from 50 W to 150 W for both filters...
3.6 Charger IC (MP26021) Figure.3-6 MP26021 FUNCTIONAL BLOCK DIAGRAM DESCRIPTION The MP26021 is a linear, high-performance single cell Li-Ion battery charger. By integrating high voltage input protection into the charger IC, the MP26021 can tolerate an input surge up to 28V. The device features constant current (CC) and constant voltage (CV) charging modes with programmable charge currents (85mA to 1A), programmable battery full threshold, thermal protection, battery temperature monitoring, reverse current blocking and trickle charge.
Page 24
‧ Battery Temperature Monitoring ‧ Over Current Protection ‧ AC Adapter Power Good Indicator ‧ Charge Status Indicator ‧ Programmable Soft-Start ‧ Programmable Charge Termination Current Threshold ‧ Tiny 10-Pin QFN (3mm x 3mm) Package APPLICATIONS ‧ Cell Phones ‧ MP3 Players ‧...
3.7 FM Radio (Si4708) Figure.3-7 Si4708 FUNCTIONAL BLOCK DIAGRAM The Si4708/09 extends Silicon Laboratories Si4700 FM tuner family, and further increases the ease and attractiveness of adding FM radio reception to mobile devices through small size and board area, minimum component count, flexible programmability, and superior, proven performance.
Page 26
same programming interface as the Si4700/01/02/03 and supports multiple bus modes. Power management is simplified with an integrated regulator allowing direct connection to a 2.7 to 5.5 V battery for VD and 2.7 to 5.5 V battery for VA. The Si4708/09 device’s high level of integration and complete FM system production testing increases quality to manufacturers, improves device yields, and simplifies device manufacturing and final testing.
3.8 LCD Interface Figure.3-8-1 LCD Interface The IM200BBN2A model is a Color TFT LCD supplied by LG Innotek. This main Module has a 2.0 inch diagonally measured active display area with 128(RGB)X160 resolution. Each pixel is divided into Red, Green and Blue sub-pixels and dots which are arranged in vertical stripes.
3.9 SIM Card Interface Figure.3-9 SIM CARD Interface Signals Description SIM_RST This signal makes SIM card to HW default status. SIM_ CLK This signal is transferred to SIM card . SIM_I/O This signal is interface datum.
3.11 Key LED Interface Figure.3-11 Key LED Interface This handset has 8 LEDs that illuminates blue color. Control signal is controlled byX-Gold102 with PWM and handset has 3 methods, ON, OFF, Dimming.
4. Trouble shooting GB130 BB Trouble shooting 4.1 Power On Trouble Test Point Check Points : - Battery Voltage(Need to over 3.35V) - Power-On key detection(PWRON signal) - Outputs of LDOs U301 (EGV) Voltage PART VBUF 2.8V VMEM 2.85V 2.85V VSIM 2.85V VRTC...
Page 75
CIRCUIT WAVE FORM RF output power in AT101, AT102 CHECKING FLOW Check RF output power form PA in U101. An analog signal pass through PAM Matching components, SW (W101), Antenna Matching components and Antenna contact point. Then finally pass it on to main Antenna.
5.2 Download tool 1. Installation. Installing this program before you must install “Prolific USB-to-Serial Comm Port” driver first. Install SetupDWForService.msi when driver installing is Okay. Click “Next” button to continue.。...
Page 92
Choose a item of what you want. Click “Next” button to continue. Make sure of setup is correct , Click “Next” Button to Start installing.
Page 93
Installation finish, Click “Close” button to finish. If you want to remove this software ,please go to “Console” and choose “add/remove Install” to remove DWForService .
Page 94
It will present a shortcut in the desktop after installing finish. This is DWForService download software.
Page 95
2. User Interface for Service Will present the screen of follows after executing the software. Description as follows. Choose PCBA item is for Reformat the PCBA with Calibration. . Choose MMI item only is for Upgrade customization SW , no need to calibration. If you want change it please modify “C:\Program Files\DownLoad\DWForService \LGDownLoad.ini”...
Page 96
2. Choose Model and Model Name. 3. Choose “Bin file” and “Search Dir” will to use .BIN file. bin file Download will skip Security & (MMI RF ,EEP Area ; PCBA bin file will over write Security & RF ,EEP Area). If you only choose “Search Dir”...
Page 97
Choose the “GB110-00-V10g-404-XX-FEB-10-2009_BIN”, and then click the button with red mark . 4. Choose Comport number. 5. Click “RUN” button to execute.
Page 98
3.Download flow 1. Start Download Will present download window after make sure of setting no error When appear above picture. Will automatic execute download program after DUT open power.
Page 99
2. Downloading Download program will according to software download. Every software will display in List.
Page 100
3. DownLoad Fail If download fail that it will show red and display progress in log window。...
Page 101
Fig.2 DownLoad success DownLoad Pass will display green color.
9. PCB LAYOUT U803 Charging IC X301 J601 Up board connector No Charging 26MHz Crystal LCM no display No TX & No RX Keypad not working U901 FM radio No FM U101 PAM (SKY77518) No TX & No RX U401 Memory No Booting U301 BB chipset (PMB7880) X302...
Page 115
J801 J603 U501 Speaker AMP J702 Battery Connector Keypad connector No Speaker SIM connector No Charging Keypad not working No SIM J701 I/O Connector No Charging etc J802 Vibrator connector No Vibrator...
10.Engineering Mode 1 Function Test 1.1 Test Purpose To verify handset functional is pass or fail when assembled by visual check. 1.2 Test Facilities List 1.LCD 2.Earphone 3.Vibrator 4.GSM tester 5.FM transmitter...
1.3 Test Procedure 1.3.1 Auto test sequence 1. Operator not need to insert test SIM card, and enter ” *#878#” to check “auto test” as below. 2. When operator into function test mode, we just press “yes” key or “enter” key to into next test item. 3.
11.Calibration 11.1 Test equipment setup 11.2 APT Technologies (calibration tool) 11.2.1 Installation Before install this program, it must install GPIB, VISA drivers and .Net Framework 2.0 at first. Press the next to continue the installation. Fig.3 APT Technologies installation...
Page 119
Choose the wireless communication test set type. Select Agilent 8960 and press next to continue installation. Only Agilent 8960 is the only available for selection at present, CMU200 has no function. Fig.4 Choose the wireless communication test set type Choose the installing catalogue; if it is necessary you can change the folder to install. Press next to continue the installation.
Page 120
Choose the wireless communication test set type. Select Agilent 8960 and press next to continue installation. Only Agilent 8960 is the only available for selection at present, CMU200 has no function. Fig.6 Choose the wireless communication test set type Choose the installing catalogue; if it is necessary you can change the folder to install. Press next to continue the installation.
Page 121
Confirm installation and press next to install the program, if need to change setting press back to set up. Fig.8 Confirm installing While installing it will appear a window like Fig.9, it will begin to install the test scripts after choosing installation, if change the catalogue of installing before, this installation catalogue must keep the same with APT.
Page 122
Installation finishes finally, pushing and closing the button finishes installing. Fig.10 It finishes to install It will present two shortcuts in the tabletop after finishing the installation: ATP Tools Icon. Auto Cable Loss Compensation Tools Icon.
Page 123
11.2.2 User's interface After opening the APT Program, it will appear a window like Fig.11, several proves as follows: Fig.11 User's interface Title: Read the station and version from equipment_config.txt, for example: Station: BOARD_TRIM_1 Version: APT V1.8.7 Script file: File of test script; show the testing script file location and file name. FT: It will select the script for Final Test.
Page 124
10. Test Time: Show the time when it has been already finished the test. 11. Arima: Company Mark, if double click this mark and input the password , will appear a window it can set the equipment_config.txt for RD. 12. Start: Begin to run the test; it will appear a window that can input Bar Code. After input the Bar Code, it will begin to run the test.
Page 125
11.2.3 Test the program Begin to test After opening the program, confirms that it is errorless to set up, some lower Start will appear the Bar Code input window, such as Fig.12, begin to test like Fig.13 after scanning or inputting Bar Code. Fig.12 Input Bar Code window...
Page 126
While testing Will accord with and test the test item by item of the script while testing, every test result will show on List. Fig.13 Sketch map while testing Item: Mainly test the procedure serial number. Sub: Test the procedure serial number less importantly. Description: It is tested that the procedure proves.
Page 127
Test fails If there is fail, the picture will show red, and will show the result in Result, if there is Error Message will show on Error. Window with Bar Code input will jump out for continue test the next mobile. If input QUIT it can close the input Bar Code window, and can make, fix or change and test the script.
Page 128
Test succeeds Test Pass will getting green, and jump out the input Bar Code window for next test. If input QUIT it can close the input Bar Code window, and can make, fix or change and test the script. Fig.15 Test succeeds in finishing the sketch map...
Page 129
11.2.4 Set up Double click the Arima icon will show set up window. Fig.16 Double click“ARIMA” icon window...
Page 130
The window for setting up Equipment_config.txt file. The item shows as follows. Fig.17 The window for setting up 1.Tester Test Address: Wireless Communication test set GPIB address. Tester Type: Type of the comprehensive tester. (0: 8960,1: CMU200.) Default Test Select: Choose default test item. 2.Power Supply Power Supply Type: Type of power supply.
Page 131
4.Test Report Test Result Drive: Set up disk drive names that result file. Test Result Dir: Set up the materials of the disk drive of the network to insert the name. If set up and does not use the disk drive of the network for Self. Type: Choose to carry out the type to test script at present.
Page 132
11.2.5 Auto Cable Loss Compensation (ACL) ACL another procedure, install, can by the way installation together, and establishment that use file corresponding to APT, this procedure must correct with Golden, the procedure will calculate Loss that should be mended and write into Cable automatically For APT procedure to use in Loss.txt file. The picture is as follows after opening.
12. Stand alone test 12.1 Test program setting 12.1.1 Set COM port 12.1.2 Check PC Baud rate (115200) 12.1.3 Confirm EEPROM &Delta file prefix name...
Page 134
12.1.4 Press power on key, then click “V24AT#ON” and then “ Update Info” for communicating Phone and Test Program 12.1.5 For the purpose of the Stand alone Test ,Change the phone to” ptest mode” and then click the “ Reset” bar 12.1.6 Select “Non signaling”...
12.2 TX Test 12.2.1 Click “Non signaling mode” bar and then confirm “OK” test in the command line. 12.2.2 Put the number of TX channel in the ARFCN. 12.2.3 Select “TX” in the RF mode menu and “PCL” in PA level menu . 12.2.4 Finally, Click “Write All”...
12.3 RX Test 12.3.1 Put the number of RX channel in the ARFCN. 12.2.2 Select “RX” in the RF mode menu. 12.2.3 Finally, Click “Write All” bar and try the efficiency test of phone.