PTAC Introduction Part 1 General information 1. Model line up ..................12 2. Nomenclature ...................13 3. Appearance..................14 4. List of functions ................15 5. Features ....................16 PTAC...
Page 3
Part 2 Product data 1 YA chassis ..................22 1.1 Features......................22 1.2 List of functions.....................23 1.3 Specifications....................24 1.4 Dimensions ....................30 1.5 Piping diagrams ....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables .....................35 1.8 Electrical characteristics ................43 1.9 Operation range....................44 1.10 Sound level test method................44 2 Control Devices................45 2.1 Electronic Controls..................45 PTAC...
Page 4
Part 3 Design and installation 1 General installation procedure............51 2 Installation of unit................52 2.1 Safety precautions ..................52 2.2 Points of explanation about operations ............55 2.3 Selecting installation site for the unit .............55 2.4 Installation of unit...................56 2.5 Wall sleeve installation ..................58 PTAC...
Page 5
Part 4 Accessories 1 Controller accessories ..............65 1.1 Hard Wire kit ....................65 1.2 Wired Wall Thermostat Connection Kit ............67 2 Mechanical accessories ..............68 2.1 Control Panel Key Lock ................68 2.2 Outer Grille ....................69 2.3 Condensate Drain Kit ..................71 2.4 Leveling Legs ....................73 2.5 Sub Base ......................74 2.6 Lateral Duct Accessory System ..............76 2.7 Replacement Filter - 10 Pack ................79...
Page 6
Test condition of International Standards 6RWU0-05B Test condition of International Standards AHRI AHAM CLASSIFICATION 9306 5151 210/240 1861.1 DB°C(°F) 27.0 27.0 26.7(80) 26.7(80) 27.0 29.0 Indoor Cooling WB°C(°F) 19.5 19.0 19.4(67) 19.4(67) 19.0 19.0 Capacity DB°C(°F) 35.0 35.0 35.0(95) 35.0(95) 35.0 46.0 Outdoor...
Packaged Terminal Air-Conditioners(PTAC) of LG is the best choice a customer can avail when it comes to a quiet environ- ment. Ultra quiet operation is the hallmark of these Air-Conditioners of LG. This range of units is suitable for Hotels and Healthcare applications.
Page 8
60Hz PTAC R410A 2016 Model Line UP 6RWU0-04A Jun,2016 60Hz PTAC R410A Spec Sheet Update Feb,2017 6RWU0-04B 60Hz PTAC R410A 2017 Model Line UP 6RWU0-05A Aug,2017 60Hz PTAC R410A Spec sheet update (add gross weight) Nov,2017 6RWU0-05B PTAC General information...
Page 9
6RWU0-05B Introduction Step by step air conditioner selection process (reference) Calculate or obtain the maximum heat load for the area to be air conditioned. Specifications Model features and functions Air-flow and temperature distribution Selection of the control system Remote Wall Thermostat Control Front Desk Control CAUTION 1.
Part 1 General information 1. Model line up ..................12 2. Nomenclature ..................13 3. Appearance ..................14 4. List of functions ..................15 5. Features ....................16 General information PTAC...
Model line up 6RWU0-05B 1. Model line up Model names Capacity, kW(kBtu/h) Chassis 2.05(7) 2.64(9) 3.52(12) 4.4(15) UYC093ALEU1(LP093CDUC) UYC123ALEU1(LP123CDUC) UYC073ALEU1(LP073CDUC) Y4NZ09ANLD1 (LP093HDUC1) Y4NZ12ANLD1 (LP123HDUC1) UYC153ALEU1(LP153CDUC) UYH073ALEU1(LP073HDUC) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH153ALEU1(LP153HDUC) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) PTAC General information...
Fan Mode + Auto Restart + Evaporator Frost Control + 2kW~5kW (Universal Heater) Freeze Room Protection + 4-Way Cooling + Condensate Pump Look L: LG Brand Production type N: In house S: Outsourcing Chassis : A – YA chassis. Capacity Ex) 07 ->...
6RWU0-05B List of functions 4. List of functions PTAC Type PTAC Type Category Function Cooling only Models Heat Pump Models Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right) Air flow Auto swing Airflow steps (fan/cool/heat)
Features 6RWU0-05B 5. Features The following features can be found in PTAC (Packaged Terminal Air-Conditioners) :- n 2 -Way Air Flow Direction n Indoor Fan Speed Setting n Washable Filters n Two Fan Motors n Low Noise at High Air Volume n LED Diagnostics and Self Diagnostics n High Efficiency Compressor n Indoor Room Freeze Protection...
Page 17
Low Noise at High Air Volume New Blowers and Fans which are bigger and stronger than earlier ones operate at low rpm’s and have higher efficiency. High Efficiency Compressor LG Rotary compressors have low noise, low vibration and higher efficiency and reliability. Energy save mode This feature employs a programmable logic which enables the unit to minimize power consumption.
Page 18
Features 6RWU0-05B Electric Heater Electric heaters are used in cold regions when instant heating is required in the room. In such cases, electric heaters are preferred over heat pump models which sometimes require long times to achieve the desired heating effect. Electric Heater are of two types –...
Page 19
This feature extends the overall life of the compressor by preventing the short cycling of the air-conditioner. When the com- pressor restarts, LG PTAC is designed to give it a minimum of three minutes to have a time of equalizing the refrigerant pressures for optimizing the cycle.
Page 20
Formation of ice reduces the airflow through the coil and hence the efficiency of the air conditioning unit. The LG PTHP employs an active reverse cycle defrost function to melt the ice off the outdoor coil for ensuring room comfort conditions and savings from extended operation.
Page 21
6RWU0-05B Part 2 Product data 1 YA chassis ...................22 1.1 Features ......................22 1.2 List of functions ....................23 1.3 Specifications ....................24 1.4 Dimensions.......................30 1.5 Piping diagrams....................31 1.6 Wiring diagrams....................33 1.7 Capacity tables ....................35 1.8 Electrical characteristics ..................43 1.9 Operation range....................44 1.10 Sound level test method...................44 2 Control Devices..................45 2.1 Electronic Controls ...................45 PTAC...
6RWU0-05B YA Chassis 1. YA Chassis Models : UYC073ALEU1(LP073CDUC) UYC093ALEU1(LP093CDUC) UYC123ALEU1(LP123CDUC) UYC153ALEU1(LP153CDUC) UYH073ALEU1(LP073HDUC) Y4NZ09ANLD1(LP093HDUC1) Y4NZ12ANLD1(LP123HDUC1) UYH153ALEU1(LP153HDUC) UYC09EALE31(LP096CD3B) UYC12EALE31(LP126CD3B) UYH09EALE31(LP096HD3B) UYH12EALE31(LP126HD3B) 1.1 Features 2 -Way Air Flow Direction Indoor Fan Speed Setting Washable Filters Two Fan Motors Low Noise at High Air Volume LED Diagnostics and Self Diagnostics High Efficiency Compressor Indoor Room Freeze Protection...
YA Chassis 6RWU0-05B 1.2 List of functions PTAC PTAC Category Function Cooling only Models Heat Pump Models Air flow Air discharge type Top discharge Top discharge Airflow direction control (up & down) Manual Manual Airflow direction control (left & right) Auto swing Airflow steps (fan/cool/heat) 2/2/2...
YA Chassis 6RWU0-05B 1.5 Piping diagrams Models : UYC073ALEU1(LP073CDUC) UYC09EALE31(LP096CD3B) UYC093ALEU1(LP093CDUC) UYC12EALE31(LP126CD3B) UYC123ALEU1(LP123CDUC) UYC153ALEU1(LP153CDUC) Liquid side Capillary Tube Heat Heat C.F.F Exchanger Exchanger (Condenser) (Evaporator) Axial Fan High Pressure S/W Compressor Gas side : 41.8/32.6(kgf/cm [595/463(lbf/in LOC. Description PCB Connector Thermistor for indoor Air temperature CN-IDAT2 Thermistor for evaporator temperature...
Control Device 6RWU0-05B 2. Control Device 2.1 Electronic Controls The Electronic Controls and the panel display is as shown below. FAN SPEED • Every time you push this button, it cycles through the settings as follows: {High(F2)) → Low(F1)) → High(F2)} HEAT HIGH F1 LOW...
Page 46
6RWU0-05B Control Device • REMOVING THE FRONT GRILLE Additional controls are available after removing the front grille and option cover of control box. To remove the front grille, pull out the bottom of front grille and then lift up. To reinstall the front grille, place the tabs over the top of the unit and push the bottom of front grille until the clips snap into place.
Page 47
Control Device 6RWU0-05B • Remote/Local Control When remote/local switch #1 is on, it allows the unit to operate by the Remote Wall Thermostat. The unit control by knobs are not applicable. • Energy Saver When the energy saver switch #2 is on, it allows the fan to provide continuous operation in cool or heat modes. When the switch is off, it allows continuous circulation of room air to provide a balanced temperature in the room.
Page 48
6RWU0-05B Control Device Remote Wall Thermostat When the wires are connected, the unit will be controlled by a remote wall thermostat. The thermostat connections supply the 24 Volt AC. When you install the digital/electronic thermostat, you must set it to 24 Volt AC.
Page 49
Control Device 6RWU0-05B • Electrical Controls Fault Description of t n i Codes Inspection • Check the error after change sensor. Indoor Air The Indoor Air Thermistor Error occurs when • Check the insertion of PCB Connector CH 01 Thermistor Error the indoor temperature is ≤-35°C or ≥100°C.
Page 50
Part 3 Design and Installation 1 General installation procedure ............51 2 Installation of unit ................52 2.1 Safety precautions....................52 2.2 Points for explanation about operations ............52 2.3 Selecting installation site for the unit ..............52 2.4 Installation of Unit .....................56 2.5 Wall sleeve installation ..................58 Design and installation PTAC...
General Installation Procedure 6RWU0-05B 1. General Installation Procedure Installation Procedure Remarks …… Check and confirm required load calculation, model Determination of work scope selection etc… …… The base or the foundation of the Air-Conditioner Selection of suitable location should be firm and vibration proof and air-flow should for unit not be restricted on either side of the unit - front and the back.
6RWU0-05B Installation of unit 2. Installation of unit 2.1 Safety precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.
Page 53
Installation of unit 6RWU0-05B WARNING Do not use a damaged power cord, plug or loose socket. • Otherwise there is risk of fire or electric shock. Always plug onto a grounded outlet. • Otherwise there is risk of fire or electric shock. Do not extend or modify the power cord length.
Page 54
6RWU0-05B Installation of unit Turn off the main power switch when the unit is not used for a long time. • We can prevent accidental startup and thereby prevent injury. Do not operate or stop the unit by inserting or pulling out the power plug. •...
Installation of unit 6RWU0-05B CAUTION Install the product in such a way that the noise or hot wind from the outdoor unit may not cause any distur- bance to neighbors. • Otherwise there may be disputes with neighbors. During installation the unit should be level front-to-back and side-to-side. •...
6RWU0-05A Installation of unit 2.4 Installation of unit The PTAC and its components are as shown below. 14 14 1. WALL SLEEVE 6. VERTICAL AIR DEFLECTOR 11. BASE PAN 2. FRONT GRILLE (HORIZONTAL LOUVER) 12. BRACE 3. AIR FILTER 7. EVAPORATOR 13.
Page 57
Wall opening 16-1/4"x42-1/4" Recommended To maintain the best performance of LG PTAC 1. An insulation strip must be attached. The insulation strip is provided with the box. 2. After assembly of unit with sleeve and front grille, the gap should be over 20” from both sleeve and front grille.
6RWU0-05B Installation of unit 2.5 WALL SLEEVE INSTALLATION Wall Case Installation Data framing, moving electrical outlets, and other expensive modifications. General Generally, units are installed 3" to 5" above the floor For existing construction it is important that carpentry, (flush to finished floor installation is possible) as near to masonry and electrical work be performed by compe- the center of the room as possible;...
Page 59
Construction room resulting in increased operating costs and improper As shipped, the LG wall sleeve is ready for installation. room temperature control. Do not remove the stiffener from inside the wall case or the...
Page 60
6RWU0-05B Installation of unit Installation PTAC...
Page 61
Installation of unit 6RWU0-05B PTAC Installation...
Page 62
6RWU0-05B Installation of unit • Unit Installation 2. Remove the front grille by pulling it out at the bottom 1. Remove the shipping screw from the ventilation door. to release it, then lift it up along the unit top front. 3.
Page 63
Installation of unit 6RWU0-05B ELECTRICAL SAFETY IMPORTANT (PLEASE READ CAREFULLY) FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. PREFERRED Use this with a standard three-slot (grounding) wall power outlet to minimize the METHOD hazard of electric shock.
Page 64
Part 4 Accessories 1 Controller accessories ...............65 1.1 Hard Wire Kit ....................65 1.2 Wired Wall Thermostat Connection Kit.............67 2 Mechanical accessories ..............68 2.1 Control Panel Key Lock ..................68 2.2 Outer Grille .......................69 2.3 Condensate Drain Kit ..................71 2.4 Leveling Legs ....................73 2.5 Sub Base ......................74 2.6 Lateral Duct Accessory System ...............76 2.7 Replacement Filter - 10 Pack ................79...
Controller accessories 6RWU0-05B 1. Controller accessories 1.1 Hard Wire Kit (265 V ONLY) The Hard Wire kit consists of a Junction box which provides a protective enclosure for the electrical connections. This junc- tion box is furnished with approximately 2 - feet of inch flexible steel conduit and a metal box that secures to the...
Page 66
6RWU0-05B Controller accessories 5) For 265 volt units, remove and discard the red lead from the wire assembly. * For 208/230 volt units and 265 volt units refer to notes given below. 6) Remove the retaining ring, which holds the threaded conduit and the metal box together, from the straight conduit clamp. Insert the three wires into the metal box through one of the two openings in the box.
Mechanical accessories 6RWU0-05B 1.2 Wired Wall Thermostat Connection Kit Installation 1. Disconnect power and remove the front panel per unit The PTAC Wire Harness kit provides connection from termi- installation instruction. nal strip on the PTAC control board to the following board features: 2.
6RWU0-05B Mechanical accessories 2. Mechanical Accessories 2.1 Control Panel Key Lock Door Hinge Pins (Each Side) Brackets (Each Side) Control Panel Key Lock Front AYCP101 The Control Panel Key Lock Kit prevents tampering with the controls used to set the temperature and other Heating and Cooling functions.
Mechanical accessories 6RWU0-05B 2.2 Outer Grille Outdoor Grilles are attached to the Wall Sleeve and exposed to the exterior Wall. These Grilles comes in industry standard size of 42" x 16". These Grilles are of two types : (a) Stamped Aluminum Grille Stamped Aluminum Grille AYRGALA01 and (b) Architecture Grille.
Page 70
The architectural design of a building may dictate the use of special or oversized louvers for aesthetic reasons. Louvers other than standard LG exterior grilles may be used on the LG unit, however, these special louvers, or any special exterior architectural treatments of the building facade that may restrict the free circulation of condenser airflow, should be referred to LG Engineering for evaluation and approval.
Mechanical accessories 6RWU0-05B 2.3 Condensate Drain Kit. During the Heat Pump operation, condensate water inside the unit drains out into the sleeve from the chassis. Such an instance may also happen at times of high humidity during the cooling operation. When normal drainage from the wall sleeve is not possible or is undesirable, this condensate drain kit can be used.
Page 72
6RWU0-05B Mechanical accessories 3) Locate the other gasket A on the back of the bank off plate and secure the assembly to the left rear of the wall sleeve with sheet metal screws provided.(refer to figure on the right) If the unit is to be installed right away, install the condenser grille to the wall sleeve with the hardware provided.
Page 73
Mechanical accessories 6RWU0-05B 1) The components D, E and the drain fitting of the kit are mount- ed on the bottom of the wall sleeve prior to the installation of the sleeve. When a subbase is not used, a suitable area on the bottom of the sleeve is selected which is inside the room.
6RWU0-05B Mechanical accessories 2.4 Leveling legs IMPORTANT: Installer is responsible for com- Leveling Leg Accessory Kits include two leveling legs as plying with all building and well as two mounting screws. National Electrical Codes. They are constructed of formed sheet metal and are engineered to provide accurate leveling and support for PTAC units which do not utilize the optional subbase.
Mechanical accessories 6RWU0-05B 2.5 Subbase The Subbase provides an enclosure for an electrical receptacle, power switch and a circuit breaker. Electrical connections to the power supply from the unit are made inside the subbase. In addition, the subbase provides structural support to the Wall Sleeve and to the weight of the PTAC unit .
Page 76
6RWU0-05B Mechanical accessories Installation Procedure: Inside Wall 1. Disconnect all power to unit. 2. Mark the hole location on sleeve then drill 1/8in holes. See Fig. 2 for hole dimensions on sleeve. 3. (Optional) Adjustable side extension panels can be SIDE VIEW OF WALL SLEEVE attached to cover open space left between subbase and 1/8”...
Mechanical accessories 6RWU0-05B 2.6 Lateral Duct Accessory System The lateral duct accessory system allows one unit to heat or cool two rooms and can be installed for left or right side duct application. Pre-Installation Things to take into consideration before installation Front Grille •...
Page 78
6RWU0-05B Mechanical accessories Install the Extension Duct 1/8” 1. Temporarily secure plenum to left and right support brackets that were previously installed. WALL 1/8” 2. Measure and cut a 3 3/4 in. X 7 1/8 in. hole through adja- cent wall(fig.2) 3 3/4”...
Mechanical accessories 6RWU0-05B 2.7 Replacement Filter ( 10 Pack ) The unit is provided with two easy-to-use replaceable mesh filters which can be cleaned periodically from time to time. Replacement Filter 10-Pack AYFT110 2.8 Wall Sleeve This Wall Sleeve comes in industry standard size of 42"...
6RWU0-05B Mechanical accessories 2.10 Remote Escutcheon Kit 3. Lift the cabinet front off the chassis. This kit provides an attractive replacement escutcheon, 4. Lift the front edge of the escutcheon as shown in figure 4. (see Figure 1). The kit allows the removal of control pads and graphics, which are not required when a wall thermo- stat is used to control the unit.
Mechanical accessories 6RWU0-05B 2.11 Vent Filter The Vent filter is used to filter the air flowing inside the room when Air Ventilation is performed by means of the ventilation lever. Installation Procedure: The Installation and servicing of the equipment should be performed by qualified and experienced personnel only.
6RWU0-05B Power cord accessories 3.1Power cord FOR 230/208 VOLT POWER CORD CONNECTIONS ONLY 1. Remove the front gille by pulling it out at the 2. Remove cover by removing 3 screws from front. bottom to release it, then lift it up along the unit top front.
Page 84
Tianjin City, 300-402, China. http://www.lgeaircon.com All rights reserved The air conditioners manufactured by LG have received ISO9001 certificate for Printed in Korea August/2017 quality assurance and ISO14001 certificate for environmental management system. The specifications, designs, and information in this brochure are subject to...