Technical Information
Option
INDEX
FAULT INDEX
FUNCTION TEST
SENSOR TEST
RUNNING TIME
Table 060-3: Service Mode
Setting/Activation
CONTROL
e.g., EPX 702
ELECTRONIC
ID33795 V.2
POWER
e.g., EPL 700
ELECTRONIC
ID00796
"No Faults" or fault code, e.g., "F 01"
Delete faults
ALL OFF
HEATING CIRCUIT 1/
On
STEAM GENERATOR
(1R25)
Off
HEATING CIRCUIT 2/
On
STEAM GENERATOR
(2R25)
Off
LOWER HEAT ELEM.
On
or FLOOR HEATER
Off
FAN (M2)
On
Off
DOOR OPENER (Y56)
On
Off
BUZZER
On
Off
DISPLAY
STEAM GENERATOR
Closed
CONTACT or STEAM
GENERATOR
CONTROL
Open
LEVEL INDICATOR or
Closed
FILL INDICATOR
Open
DOOR SWITCH
Closed
Open
TEMP INTERIOR
e.g., 81°F
KEYPAD or FUNCTION PAD PANEL
HEATING CIRCUIT 1
e.g., 0008h
HEATING CIRCUIT 2
e.g., 0008h
LOWER HEAT ELEM.
e.g., 0005h
or FLOOR HEATER
DESCALE or NO. OF
e.g., 1
DESCALES
50
DG 408x Steam Ovens
Description
The ID number of the control
electronic (2N1) is indicated.
The ID number of the power
electronic (3N1) is indicated.
All faults registered so far are
indicated; refer to Table 060-1.
All saved faults are deleted.
All components are switched off.
Steam generator heater (1R25)
is switched on.
Steam generator heater (1R25)
is switched off.
Steam generator heater (2R25)
is switched on.
Steam generator heater (2R25)
is switched off.
Floor heater R28 is switched on.
Floor heater R28 is switched off.
The fan (M2) is switched on.
The fan (M2) is switched off.
The release element (Y56) is
activated and controls the door
opener via a metal rod, which
opens the door a crack.
The door closes again slowly.
The buzzer sounds.
The buzzer goes silent.
The display alternately lights up
and goes dark.
Steam generator is inserted. The
steam generator switch (S84) is
switched on.
Steam generator is not inserted.
The steam generator is filled.
The level switch (S12) is
switched on.
The steam generator is not filled.
Door is closed. Door contact
switch (S4) is switched on.
The door is open.
The temperature at the PT 1000
temperature sensor (R30) is
indicated. (F06 if open circuited.)
All keypads, with the exception of
"Timer" and "Off" (DG 4082) or
"Clear" and "Off" (DG 4080), can
be checked by touch.
The operating hours of heater
1R25 are indicated.
The operating hours of heater
2R25 are indicated.
The operating hours of heater
R28 are indicated.
The number of descales
performed is indicated.