Page 2
THERMA V Split Type General Information Indoor Unit Hydro Box Unit DHW Tank Integrated Unit Outdoor unit Design and installation...
Page 3
Split Type General Information THERMA V 1.Model Line Up 2.Nomenclature...
Page 4
THERMA V Split Type General Information 1. Model line up 1.1 Indoor Units Model Name Heater External Heating Capacity Capacity Category Type Features class* (kW) Appearance [kW] 16.0 • Prividing eco-friendly heating AHNW16606A3 • High energy efficiency [HN1616 NK3] • Easy installation Hydro Box Type •...
Page 5
THERMA V Split Type General Information 2. Nomenclature 2.1 Indoor Unit Global Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit of Split type U : Outdoor unit of Split type B : Monobloc type Model Type W : Inverter Heat Pump H : Heat Pump...
Page 6
THERMA V Split Type General Information 2. Nomenclature European Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit of Split type U : Outdoor unit of Split type M : Monobloc type Heating Capacity (kW) Ex) 9kW '09', 12kW '12'...
Page 7
THERMA V Split Type General Information 2. Nomenclature 2.2 Outdoor Unit Global Name Model Name Signification Air-to-Water Heat Pump for R410A Classification N : Indoor unit U : Outdoor unit : Set Model Type W : Inverter Heat Pump H : Heat Pump Heating Capacity (kW) Ex) 5kW : ‘05’, 16kW : '16' Electrical ratings...
Page 8
THERMA V Split Type General Information 2. Nomenclature European Name Model Name Signification H : Air-to-Water Heat Pump for R410A Classification U : Outdoor unit Heating Capacity (kW) Ex) 5kW : ‘05’, 16kW : '16' Electrical ratings 1 : 1Ø, 220-240V AC 50 Hz 3 : 3Ø, 380-415V AC 50 Hz Classification N : Indoor unit of Split type...
Page 9
Split Type Indoor Unit THERMA V Hydro Box Unit DHW Tank Integrated Unit...
Page 10
Split Type Hydro Box Unit THERMA V 1.List of Functions 2.Specification 3.Dimensions 4.Wiring Diagram 5.Piping Diagram 6.Hydraulic Performance 7.Sound Levels...
Page 11
THERMA V Split Type Hydro Box Unit 1. List of Functions Basic functions of Unit AHNW16606A3 [HN1616 NK3] Category Function AHNW16809A3 [HN1639 NK3] Drain pump E.S.P. control Installation Electric heater(operation) High ceiling operation Hot start Reliability Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence)
Page 12
THERMA V Split Type Hydro Box Unit 1. List of Functions Accessory Compatibility List AHNW16606A3 [HN1616 NK3] Category Product Remark AHNW16809A3 [HN1639 NK3] Simple Contact PDRYCB000 Simple Dry Contact 2 Points Dry Contact PDRYCB400 (For Setback) Dry Contact Communication Type 8 Points Dry Contact PDRYCB300 (For Thermostat)
Page 13
Power Supply Type Separated power source Separated power source DHW Tank** Thermal Protector Range Max. °C (Field Supply) Relay Contactor Needed Needed ELCB Sensor Adaptor Diameter mm(inch) 12.7 (1/2) 12.7 (1/2) Accessory Kit Model Name*** PHLTA (LG Supply) PHLTA (LG Supply) MCCB...
Page 14
THERMA V Split Type Hydro Box Unit 2. Specifications AHNW16606A3 AHNW16809A3 Electrical Specification [HN1616 NK3] [HN1639 NK3] Type Sheath Sheath Number of Heating Coil Capacity Combination 3.0 + 3.0 3.0 + 3.0 + 3.0 Operation Automatic Automatic Electric Heater Heating Steps Step Power Supply V, Ø, Hz...
Page 15
THERMA V Split Type Hydro Box Unit 3. Dimensions 3.1 Internal AHNW16606A3 [HN1616 NK3], AHNW16809A3 [HN1639 NK3]...
Page 16
THERMA V Split Type Hydro Box Unit 3. Dimensions 3.2 External AHNW16606A3 [HN1616 NK3], AHNW16606A3 [HN1616 NK3]...
Page 17
THERMA V Split Type Hydro Box Unit 4. Wiring Diagrams AHNW16606A3 [HN1616 NK3]...
Page 18
THERMA V Split Type Hydro Box Unit 4. Wiring Diagrams AHNW16809A3 [HN1639 NK3]...
Page 19
THERMA V Split Type Hydro Box Unit 5. Piping Diagram AHNW16606A3 [HN1616 NK3] / AHNW16809A3 [HN1639 NK3]...
Page 20
Solar panel, Sensors, SOLAR Thermostats, Interim heat exchanger, - 3rd party accessory and Field installation THERMAL Water pump, etc.- To utilized hot (no connector) (sold separately) SYSTEM water heated by SOLAR THERMAL SYSTEM, end-user must by LG AWHP Solar-Kit.
Page 21
THERMA V Split Type Hydro Box Unit 6. Hydraulic Performance 6.1 Water Pump Capacity Water volume and pump capacity The water pump is BLDC, so it may be required to change default water pump speed in case of noise by waterflow. In most case, however, it is strongly recommended to set speed as Maximum.
Page 22
THERMA V Split Type Hydro Box Unit 6. Hydraulic Performance 6.2 Water Volume and Expansion Vessel Pressure Expansion vessel inside Hydro Box Unit is included which is 8 liter capacity with 1 bar pre-pressure. That means, according to the volume-pressure graph, total water volume of 230 liter is supported as default. If total water volume is changed because of installation condition, the pre-pressure should be adjusted to secure proper operation.
Page 23
THERMA V Split Type Hydro Box Unit 7. Sound levels Sound Power Level Note 1. Data is valid at diffuse field condition. 2. Reference acoustic intensity 0dB = 10E-6μW/m 3. Sound power level is measured on the rated condition in the reverberation rooms. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.
Page 24
Split Type DHW Tank Integrated Unit THERMA V 1.List of functions 2.Specification 3.Drawing 4.Wiring Diagrams 5.Piping Diagrams 6.Performance Data 7.Water Pump Capacity 8.Accessories...
Page 25
THERMA V Split Type DHW Tank Integrated Unit 1. List of Functions List of functions AHNW16606B0 Category Functions [HN1616T NB0] Electric heater Installation Domestic Hot Water Tank heater (Install Kit) Screed Drying Mode Reliability Self diagnosis Auto Restart operation Child lock Sleep mode Convenience...
Page 26
THERMA V Split Type DHW Tank Integrated Unit 2. Specifications Technical Specifications Indoor Unit Model Name AHNW16606B0 [HN1616T NB0] For Fan Coil Unit °C 7 ~ 25 Cooling Operation (Min.~Max.) For under floor °C 7 ~ 25 Range Heating For Fan Coil Unit /Radiator °C 25 ~ 58...
Page 27
THERMA V Split Type DHW Tank Integrated Unit 2. Specifications Electrical Specifications Indoor Unit Model Name AHNW16606B0 [HN1616T NB0] Power Supply V, Ø, Hz 230, 1, 50 Power Cable (Included Earth)1) No. × mm² 3C × 4.0 (H07RN-F) L1,N,Earth Power connection wiring Heater Type Sheath...
Page 28
THERMA V Split Type DHW Tank Integrated Unit 3. Drawing AHNW16606B0 [HN1616T NB0]...
Page 29
THERMA V Split Type DHW Tank Integrated Unit 4. Wiring diagrams AHNW16606B0 [HN1616T NB0]...
Page 30
THERMA V Split Type DHW Tank Integrated Unit 4. Wiring diagrams Connecting Elements mark Description Terminals A : Indoor unit Controller Basic input/output module MD1 Communication with I/O module MD2 Communication with the control electronics of the PLC screen module Set-up of bridges (without) Connecting terminal for communication with expansion module MD2 A+, B-...
Page 31
THERMA V Split Type DHW Tank Integrated Unit 4. Wiring diagrams Indoor unit Controller...
Page 32
THERMA V Split Type DHW Tank Integrated Unit 4. Wiring diagrams Element Connecting Terminals Description Marks L1, L2, L3, N, PE Power cable A5, GND Temperature sensor for external temperature Q11, N Cooling valve Q12, N, PE Additional external source Q7, N, PE Circulation pump of heating cycle 1 (optional) Q8, N, PE...
Page 33
THERMA V Split Type DHW Tank Integrated Unit 5. Piping diagrams DHW Tank Integrated Unit Basic installation (IDU + ODU) Indoor Unit TANK (Optional) 3Way Valve Electric Heater Water Pump 1 : Ball valve 2 : Pressure reducing valve 3 : Check valve Buffer Tank 4 : Safety valve...
Page 34
THERMA V Split Type DHW Tank Integrated Unit 6. Performance Data 6.1 Domestic Hot Water Volume Water Volume means amount of water that can be tapped with a temperature of 40 when the DHW tank has been heated up to a indicated temperature. AHUW096A3 [HU091 U43] AHUW16*A3 [HU16* U33] AHUW14*A3 [HU14* U33]...
Page 35
THERMA V Split Type DHW Tank Integrated Unit 6. Performance Data 6.2 Domestic Hot Water Performance AHUW096A3 [HU091 U43] AHUW16*A3 [HU16* U33] AHUW14*A3 [HU14* U33] AHUW12*A3 [HU12* U33] Tank temperature [ ˚C] Note • Heat up time means time required to heat up the water in tank starting from a temperature of 10 up to the indicated temperature.
Page 36
THERMA V Split Type DHW Tank Integrated Unit 7. Water Pump Capacity The water pump is three speed-adjustable (Maximum / Medium / Minimum), but Minimum step is not used. It is recommended to use Maximum or Medium steps. In case of noise by water flow, it may be required to change default water pump speed.
Page 37
THERMA V Split Type DHW Tank Integrated Unit 8. Accessories 8.1 Modbus Converter (PP485B00K) 8.1.1 Part Description 1 2 3 4 5 6 7 8 Modbus Gateway For Indoor Unit • LED01G, 02G, 03G: Communication Status LED • LED1:RS-485 Status LED •...
Page 38
THERMA V Split Type DHW Tank Integrated Unit 8. Accessories Accessory Part List Multi-V 1 2 3 4 5 6 7 8 PP485B00K BRACKET (1EA) SCREW (4EA) Multi Multi-V WIRE ASSY 1(1EA) WIRE ASSY 2(1EA) WIRE ASSY 3(1EA) Others : Tie Wrap (3 EA) - Cable Tie Clamp (1 EA) 8.1.2 Installation Guide Connect CN_OUT with Outdoor Unit by the cable(provided).
Page 39
Split Type Outdoor unit THERMA V 1.List of functions 2.Specification 3.Dimensions 4.Wiring Diagram 5.Piping Diagram 6.Performance Data 7.Operation Range 8.Electric Characteristics 9.Sound Levels...
Page 40
THERMA V Split Type Outdoor unit 1. List of functions Basic functions of Unit AHUW056A3 [HU051 U43] AHUW076A3 [HU071 U43] AHUW096A3 [HU091 U43] AHUW126A3 [HU121 U33] Category AHUW146A3 [HU141 U33] AHUW166A3 [HU161 U33] AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] AHUW168A3 [HU163 U33] Defrost / Deicing High pressure switch Low pressure switch...
Page 41
THERMA V Split Type Outdoor unit 2. Specifications 2.1 Nominal Capacity and Power Input Combination with Hydro Box type Outdoor Unit AHUW056A3 [HU051 U43] AHUW076A3 [HU071 U43] Model Names Indoor Unit AHNW16606A3 [HN1616 NK3] AHNW16606A3 [HN1616 NK3] Cooling Capacity (Rated) Heating Cooling 1.09...
Page 42
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Unit AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] Model Names Indoor Unit AHNW16809A3 [HN1639 NK3] AHNW16809A3 [HN1639 NK3] Cooling 10.4 12.0 Capacity (Rated) Heating 12.0 14.0 Cooling 2.60 3.08 Power Input (Rated) Heating 2.64 3.18...
Page 43
THERMA V Split Type Outdoor unit 2. Specifications Combination with DHW tank Integrated type Outdoor Unit AHUW096A3 [HU091 U43] AHUW126A3 [HU121 U33] Model Names Indoor Unit AHNW16606B0 [HN1616T NB0] AHNW16606B0 [HN1616T NB0] Cooling 10.4 Capacity (Rated) Heating 12.0 Cooling 2.88 3.30 Power Input (Rated) Heating...
Page 44
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Unit AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] Model Names Indoor Unit AHNW16606B0 [HN1616T NB0] AHNW16606B0 [HN1616T NB0] Cooling 10.4 11.0 Capacity (Rated) Heating 12.0 14.0 Cooling 3.30 3.53 Power Input (Rated) Heating 2.78 3.43...
Page 45
THERMA V Split Type Outdoor unit 2. Specifications 2.2 Outdoor Unit Specifications Outdoor Units AHUW056A3 [HU051 U43] AHUW076A3 [HU071 U43] Power Supply V, Ø, Hz 220-240 / 1 / 50 220-240 / 1 / 50 Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range...
Page 46
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW096A3 [HU091 U43] AHUW126A3 [HU121 U33] Power Supply V, Ø, Hz 220-240 / 1 / 50 220-240 / 1 / 50 Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating...
Page 47
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW146A3 [HU141 U33] AHUW166A3 [HU161 U33] Power Supply V, Ø, Hz 220-240 / 1 / 50 220-240 / 1 / 50 Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating...
Page 48
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW128A3 [HU123 U33] AHUW148A3 [HU143 U33] Power Supply V, Ø, Hz 380-415 / 1 / 50 380-415 / 1 / 50 Cooling Min. ~ Max. °C DB 5 ~ 48 5 ~ 48 Operation Range Heating...
Page 49
THERMA V Split Type Outdoor unit 2. Specifications Outdoor Units AHUW168A3 [HU163 U33] Power Supply V, Ø, Hz 380-415 / 3 / 50 Cooling Min. ~ Max. °C DB 5 ~ 48 Operation Range Heating Min. ~ Max. °C DB -20 ~ 35 (Outdoor Tempera- Domestic Hot...
Page 50
THERMA V Split Type Outdoor unit 3. Dimensions AHUW056A3 [HU051 U43], AHUW076A3 [HU071 U43], AHUW096A3 [HU091 U43]...
Page 51
THERMA V Split Type Outdoor unit 3. Dimensions AHUW146A3 [HU141 U33], AHUW166A3 [HU161 U33], AHUW128A3 [HU123 U33], AHUW148A3 [HU143 U33], AHUW168A3 [HU163 U33], AHUW126A3 [HU121 U33]...
Page 52
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW056A3 [HU051 U43], AHUW076A3 [HU071 U43], AHUW096A3 [HU091 U43]...
Page 53
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW126A3 [HU121 U33], AHUW146A3 [HU141 U33], AHUW166A3 [HU161 U33]...
Page 54
THERMA V Split Type Outdoor unit 4. Wiring Diagrams AHUW128A3 [HU123 U33], AHUW148A3 [HU143 U33], AHUW168A3 [HU163 U33]...
Page 55
THERMA V Split Type Outdoor unit 5. Piping Diagram LIQUID SIDE Service Indoor Unit Plate Heat Valve Exchanger (3 way) Water. Out Outdoor Unit Heat Exchanger Water. In 4 way Pressure Valve GAS SIDE Sensor Service (Accessories) Valve (3 way) Accumulator Compressor ...
Page 56
THERMA V Split Type Outdoor unit 6. Performance Data 6.1 Cooling Operation 6.1.1 Combination with Hydro Box type AHUW056A3 [HU051 U43] + AHNW16606A3 [HN1616 NK3] LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C Outdoor Temperature 3.65 0.67...
Page 57
THERMA V Split Type Outdoor unit 6. Performance Data AHUW166A3 [HU161 U33] + AHNW16606A3 [HN1616 NK3] LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C Outdoor Temperature 8.54 1.97 10.69 2.36 11.89 2.52 12.91 2.68 13.98 2.85 14.97...
Page 58
THERMA V Split Type Outdoor unit 6. Performance Data 6.1.2 Combination with DHW tank Integrated type AHUW096A3 [HU091 U43] + AHNW16606B0 [HN1616T NB0] LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C Outdoor Temperature 7.30 2.51 8.09 2.54...
Page 59
THERMA V Split Type Outdoor unit 6. Performance Data AHUW148A3 [HU143 U33] + AHNW16606B0 [HN1616T NB0] LWT 7°C LWT 10°C LWT 13°C LWT 15°C LWT 18°C LWT 20°C LWT 22°C Outdoor Temperature 7.43 2.58 8.53 2.60 9.62 2.62 10.35 2.64 11.45 2.66 12.18...
Page 60
THERMA V Split Type Outdoor unit 6. Performance Data 6.2 Heating Operation 6.2.1 Combination with Hydro Box type AHUW056A3 [HU051 U43] + AHNW16606A3 [HN1616 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature...
Page 61
THERMA V Split Type Outdoor unit 6. Performance Data AHUW076A3 [HU071 U43] + AHNW16606A3 [HN1616 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 4.26 1.90 4.34 2.46 4.42 3.02...
Page 62
THERMA V Split Type Outdoor unit 6. Performance Data AHUW126A3 [HU121 U33] + AHNW16606A3 [HN1616 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 11.36 2.62 11.36 3.31 11.36 4.99...
Page 63
THERMA V Split Type Outdoor unit 6. Performance Data AHUW146A3 [HU141 U33] + AHNW16606A3 [HN1616 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.84 3.67 12.50 4.12 12.06 5.30...
Page 64
THERMA V Split Type Outdoor unit 6. Performance Data AHUW166A3 [HU161 U33] + AHNW16606A3 [HN1616 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 13.45 4.53 12.76 4.91 12.06 5.30...
Page 65
THERMA V Split Type Outdoor unit 6. Performance Data AHUW128A3 [HU123 U33] + AHNW16809A3 [HN1639 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 11.36 2.62 11.36 3.31 11.36 4.99...
Page 66
THERMA V Split Type Outdoor unit 6. Performance Data AHUW148A3 [HU143 U33] + AHNW16809A3 [HN1639 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.84 3.67 12.50 4.12 12.06 5.30...
Page 67
THERMA V Split Type Outdoor unit 6. Performance Data AHUW168A3 [HU163 U33] + AHNW16809A3 [HN1639 NK3] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 13.45 4.53 12.76 4.91 12.06 5.30...
Page 68
THERMA V Split Type Outdoor unit 6. Performance Data 6.2.2 Combination with DHW tank Integrated type AHUW096A3 [HU091 U43] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 7.38...
Page 69
THERMA V Split Type Outdoor unit 6. Performance Data AHUW126A3 [HU121 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 10.66 2.68 10.77 3.31 11.12 5.26...
Page 70
THERMA V Split Type Outdoor unit 6. Performance Data AHUW146A3 [HU141 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.30 3.69 11.98 4.12 11.55 5.46...
Page 71
THERMA V Split Type Outdoor unit 6. Performance Data AHUW166A3 [HU161 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.88 5.01 12.22 5.23 11.55 5.46...
Page 72
THERMA V Split Type Outdoor unit 6. Performance Data AHUW128A3 [HU123 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 10.66 2.68 10.77 3.31 11.12 5.26...
Page 73
THERMA V Split Type Outdoor unit 6. Performance Data AHUW148A3 [HU143 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.30 3.69 11.98 4.12 11.55 5.46...
Page 74
THERMA V Split Type Outdoor unit 6. Performance Data AHUW168A3 [HU163 U33] + AHNW16606B0 [HN1616T NB0] Peak Capacity (Not included defrost effect) Outdoor LWT 30 LWT 35 LWT 40 LWT 45 LWT 50 LWT 55 Temperature 12.88 5.01 12.22 5.23 11.55 5.46...
Page 75
THERMA V Split Type Outdoor unit 7. Operation Range Cooling Cooling (Fan coil unit) (Under floor) Leaving Water Temperature( Leaving Water Temperature( Continuous Operation Continuous Operation Operative Operative Heating Leaving Water Temperature( Continuous Operation Operative...
Page 76
THERMA V Split Type Outdoor unit 8. Electric characteristics Wiring of Main Power Supply and Equipment Capacity 1. Use a separate power supply for the Outdoor Unit and Indoor Unit. 2. Bear in mind ambient conditions (ambient temperature,direct sunlight, rain liquid,etc.) when proceeding with the wiring and connections 3.
Page 77
THERMA V Split Type Outdoor unit 8. Electric characteristics Outdoor Unit and Hydro Box Unit Power Supply Model Power Supply for Heater for Heat Pump Back-up Heater DHW Tank Heater Circuit Breaker (A) Phase Circuit Breaker Back-up Indoor Unit Outdoor Unit Volts Back-up Capacity...
Page 78
THERMA V Split Type Outdoor unit 8. Electric characteristics DHW Tank integrated Unit Power Supply Model for Electric Heater Phase Combination of Circuit Breaker Electric Heater Indoor Unit Volts Capacity (kW) Power (kW) 220-240V 1~ 230V 50Hz 16.0 50Hz AHNW16606B0 2.0+2.0 220-240V 1~ 230V 50Hz...
Page 79
THERMA V Split Type Outdoor unit 9. Sound Levels Note 1. Data is valid at diffuse field condition. 2. Reference acoustic intensity 0dB = 10E-6μW/m 3. Sound power level is measured on the rated condition in the reverberation rooms. Refer to the Model Specifications for nominal conditions(Power source and Ambient temperature, etc) 4.
Page 80
Split Type Design and installation THERMA V 1.Alternative Refrigerant R410A 2.Select the Best Location 3.Installation Space 4.Water Control 5.Lifting Method 6.Installation 7.Electrical Wiring 8.Test Run...
Page 81
THERMA V Split Type Design and installation 1. Alternative Refrigerant R410A • The refrigerant R410A has the property of higher operating pressure in comparison with R22. Therefore, all materials have the characteristics of higher resisting pressure than R22 ones and this characteristic should be also considered during the installation.R410A is an azeotrope of R32 and R125 mixed at 50:50, so the ozone depletion potential (ODP) of R410A is 0.
Page 82
THERMA V Split Type Design and installation 2. Select the Best Location Select space for installing unit, which will meet the following conditions: • No direct thermal radiation from other heat sources • No possibility of annoying neighbors by noise from unit •...
Page 83
THERMA V Split Type Design and installation 3. Installation Space 3.1 Clearance around outdoor units • Ensure that the space around the back is 300 mm or more 300 mm or more 300 mm or more more than 300 mm on the or more opposite to the PCB side and secure 600 mm space near the compressor and PCB...
Page 84
THERMA V Split Type Design and installation 4. Water Control 4.1 Water quality Water quality should be complied with EN 98/83 EC Directives. Detailed water quality condition can be found in EN 98/83 EC Directives. CAUTION • If the product is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove sludge and scale.
Page 85
THERMA V Split Type Design and installation 4. Water Control 4.3 Capacity correction factor by antifreeze Antifreeze % by wt Antifreeze Type Item Cooling 0.998 0.997 0.995 0.993 0.992 Methanol Heating 0.995 0.990 0.985 0.979 0.974 Pressure Drop 1.023 1.057 1.091 1.122 1.160...
Page 86
THERMA V Split Type Design and installation 5. Lifting Method • When carrying the suspended unit, pass the ropes under the unit and use the two suspension points each at the front and rear. • Always lift the unit with ropes attached at four points so that impact is not applied to the unit. •...
Page 87
THERMA V Split Type Design and installation 6. Installation 6.1 Foundation for Installation • Check the strength and level of the installation ground so that the unit will not cause any operating vibration ornoise after installation. • Fix the unit securely by means of the foundation bolts. (Prepare 4sets of M12 foundation bolts, nuts and washerseach which are available on the market.) •...
Page 88
THERMA V Split Type Design and installation 6. Installation 6.2 Water Piping and water Circuit Connection 6.2.1 General considerations • Followings are should be considered before beginning water circuit connection. • Service space should be secured. • Water pipes and connections should be cleaned using water. •...
Page 89
THERMA V Split Type Design and installation 6. Installation WARNING • Water condensation on the floor While cooling operation, it is very important to keep leaving water temperature higher than 16 . Otherwise, dewcondensation can be occurred on the floor.If floor is in humid environment, do not set leaving water temperature below 18 °C.
Page 90
THERMA V Split Type Design and installation 6. Installation 6.3 Installation Scenes(Hydro Box Unit) If is installed with pre-existing boiler, the boiler and THERMA V should not be operated together. If entering water temperature of THERMA V is above 57 °C, the system will stop operation to prevent mechanical damage of the unit.
Page 91
THERMA V Split Type Design and installation 6. Installation CASE2 : Connecting DHW tank (Under floor loop, Fan coil unit and Radiator) Outdoor Indoor Outdoor Unit Indoor Unit Hot water Fan coil unit Floor heating loop Radiator Domestic hot water ※...
Page 92
THERMA V Split Type Design and installation 6. Installation CASE4 : Connecting 2 Circuit [Room A] Main Zone zone (Low Temp.) Outdoor Indoor Outdoor Unit Indoor Unit Mix Kit Floor heating loop Floor heating loop Buffer Tank M / F [Room B] Additional zone (High Temp.) Radiator Radiator...
Page 93
THERMA V Split Type Design and installation 6. Installation 6.4 Installation Scenes(DHW Tank Integrated Unit) If is installed with pre-existing boiler, the boiler and THERMA V should not be operated together. If entering water temperature of THERMA V is above 57 °C, the system will stop operation to prevent mechanical damage of the unit.
Page 94
THERMA V Split Type Design and installation 6. Installation CASE2 : Connecting Solar thermal system Domestic Hot water Outdoor Indoor City water Outdoor Unit Indoor Unit Magnetic Filter (Recommended) Solar heat source Fan coil unit Floor heating loop Radiator Buffer tank ※...
Page 95
THERMA V Split Type Design and installation 6. Installation 6.5 Water charging For water charging, please follow below procedures. • Step 1 Open all valves of whole water circuit. Supplied water should be charged not only inside the indoor unit, but also in the under floor water circuit, DHW tank circuit, FCU water circuit, and any other water circuitscontrolled by the product.
Page 96
THERMA V Split Type Design and installation 6. Installation 6.6 Evacuation 1. Connect the charge hose end described in the preceding steps to the vacuum pump to evacuate the tubing and indoor unit. Confirm the "Lo and Hi" knob of the manifold valve isopen. Then, run the vacuum pump. The operation time for evacuation varies with tubing length and capacity of the pump.
Page 97
THERMA V Split Type Design and installation 7. Electrical Wiring 7.1 Caution 1. Follow ordinance of your governmental organization for technical standard related to electrical equipment, wiring regulations and guidance of each electric power company. WARNING • Be sure to have authorized electrical engineers do the electric work using special circuits in accordance with regulations and this installation manual.
Page 98
THERMA V Split Type Design and installation 7. Electrical Wiring Power Cable Specification The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4 S4 (Rubber insulated cord, type 60245 IEC 66 or H07RN-F) If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Page 99
THERMA V Split Type Design and installation 7. Electrical Wiring NORMAL CROSS-SECTIONAL AREA CAUTION • The Power cord 1 Phase(Ø) – connected to the outdoor unit should be compliedwithIEC 60245 or HD 22.4 S4 (This equipment shall be provided with acord set complying with the national regulation.
Page 100
THERMA V Split Type Design and installation 7. Electrical Wiring 7.2 Wiring Procedure for Power Cable and Connecting Cable 1. Disassemble the side panel from the outdoor unit by loosing screws. 2. Connect Power cable to Main Power Terminal and Connecting cable to Control Terminal, respectively. See below figure for detailed information.
Page 101
THERMA V Split Type Design and installation 7. Electrical Wiring 7.3 Dip switch information Turn off electric power supply before setting DIP switch • Whenever adjusting DIP switch, turn off electric power supply to avoid electric shock. Indoor PCB OFF is selected ON is selected...
Page 102
Reserved Option Switch 3 Descr Description iption Setting ting Default ault LG Room sensor is not installed (Remote) Room air sensor Remote sensor is installed Antifreeze mode not used Antifreeze mode Antifreeze mode used Reserved Reserved Reserved Not Use...
Page 103
THERMA V Split Type Design and installation 7. Electrical Wiring Option Switch 2 Descr Description iption Setting ting Default ault As Master Role when central controller is equipped As Slave Heat pump is installed (Heating(Cooling) circuit only) Heat pump + DHW tank Accessory installation is installed...
Page 104
THERMA V Split Type Design and installation 8. Starting Operation • Before starting operation, pre-check points are described in this chapter. 8.1 Starting Operation flow chart START Check whether the power cable and Operate the unit in cooling mode. communication cable are completely connected Does Test operation start? Is water discharged for * Check the load (In/Out Temp.)
Page 105
Product Installation • Refrigerant leakage degrades the performance. If leakage found, Refrigerant leakage contact qualified LG air conditioning installation person. • While cooling operation, condensed dew can drop down to the bottom Drainage treatment of the unit. In this case, prepare drainage treatment (for example,...
Page 106
THERMA V Split Type Design and installation 8. Starting Operation 8.3 Maintenance To assure best performance of THERMA V, it is required to perform periodical check and maintenance. It isrecommended to proceed following check list for once a year. Turn off the power before proceeding maintenance Category Item Check Point...