Remote controller custom code setting
When two or more air conditioners are installed in a room and the
remote controller is operating an air conditioner other than the one you
wish to set, change the custom code of the remote controller to operate
only the air conditioner you wish to set (4 selections possible).
When two or more air conditioners are installed in a room, please
contact your retailer to set the individual air conditioner custom codes.
Use the following steps to select the custom
code of the remote controller.
(Note that the air conditioner cannot receive
a signal if the air conditioner has not been set
for the matching custom code.)
1. Press the START/STOP button until only the
clock is displayed on the remote controller
display.
2. Press the MODE button for at least ve
seconds to display the current custom code
(initially set to A).
3. Press the SET TEMP. (
between A B C D.
Match the code on the display to the air conditioner custom code.
4. Press the MODE button again to return to the clock display. The
custom code will be changed.
• If no buttons are pressed within 30 seconds after the custom code is dis-
played, the system returns to the original clock display. In this case, start
again from step 1.
• The air conditioner custom code is set to A prior to shipment.
Contact our authorized service personnel to change the custom code.
• Depending on the remote controller, the custom code may return to custom
code A when the batteries are replaced. In this case,if you use a code other
than A, reset the code after replacing the batteries. If you do not know the air
conditioner custom code setting,try each code A B C D until you nd
the code which operates the air conditioner.
Wired Remote Controller (Option)
The optional wired remote controller can be used.
When you use remote controller, there are following different points as
compared with using wireless remote controller.
[The additional functions for wired remote controller]
• Temperature set back timer
And, you can use wired and wireless remote controller together.
However, you must change some restricted functions of wireless remote
controller to invalid.
If restricted function is valid, remote controller cannot use correctly.
(beeping sound will be heard, OPERATION, TIMER and the ECONOMY
indicator of the indoor unit will ash.)
[The restricted functions for wireless remote controller]
<Polar 3-core wired remote controller>
• Outdoor unit low noise
• Energy saving
• Powerful
• Timer operation
En-6
OPERATING MANUAL
/
) button to change the custom code
Timer Operation
Note for timer settings:
Any interruption of the power supply, such as a blackout or cutting off
of a circuit breaker, makes the set internal clock incorrect.
In such a case, the TIMER indicator on the indoor unit blinks, and you
need to readjust the setting.
ON timer or OFF timer
You can set the ON timer or OFF timer with the following steps.
Press the TIMER SETTING button to start the setting.
1
The WEEKLY indicator will be ashing on the remote controller.
Press the SELECT button to choose the desired mode. The mode
2
will change as follows:
ON/OFF
WEEKLY
(ON)
Press the NEXT button. Continue to setting for each mode.
3
* To cancel timer setting during the setting process, press the
TIMER SETTING button again.
Adjust the time by pressing the SELECT button while the clock
4
indicator is blinking. Each time you press the button, the time will
change by +5/-5 minutes. Pressing down will change the time by
+10/-10 minutes.
Press the SEND button.
5
To redo the timer setting, perform step 1 to 5 again.
To cancel the ON/OFF timer, press the ON/OFF button while the ON/
OFF indicator is on. (Erases the indicator)
Program timer (combined use of the ON timer and the OFF timer)
You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose con gured starting time is closer to the
current time works rst, and the order of timer operation is displayed
as follows:
Timer
Indicator on remote controller display
ON–OFF timer
OFF–ON timer
To set the program timer, conduct the same steps 1~5 for the ON/
OFF timer. (Select ON OFF in Step 2)
Notes:
• If you change the setting value for the timer after the program timer
is set, the counting down of the timer will be reset at that moment.
• Time setting for each combination should be within a span of 24 hours.
SLEEP timer
To set the SLEEP timer, rst follow steps 1~3 for the ON/OFF timer.
Adjust the time by pressing the SELECT button while the clock
4
indicator is blinking.
Each time you press the button, the time changes as follows:
0H
1H
2H
30M
00M
00M
(30 min.)
Press the SEND button.
5
To cancel the SLEEP timer, press the SLEEP button while the SLEEP
indicator is on. (Erases the indicator)
To help you to fall asleep comfortably and prevent excessive
cooling in sleep, the SLEEP timer controls the temperature setting
automatically in accordance with the set time shown as follows. The
air conditioner completely turns off after the set time has elapsed.
In COOL or DRY mode
Set temperature
ON/OFF
ON/OFF
SLEEP
(OFF)
(OFF)
(ON
OFF)
3H
5H
7H
9H
00M
00M
00M
00M
hours
Set time
1 hour
2 °C
1 °C
(continued)