hit counter code

Miele PWM 509 Installations Plan page 41

Commercial washing machine
Hide thumbs Also See for PWM 509:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
3 AC 230 V EL DP
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
1N AC 230 V EL DV
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
1N AC 230 V EL DP
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
1N AC 230 V EL DP
Supply voltage
Frequency
Required fuse rating (on site)
Circuit breaker trip characteristic
Power rating
Connection cable, min. cross-section
en - Technical data
3 AC 230 V
4 x 2,5 mm²
1N AC 230 V
3 x 2,5 mm²
1N AC 230 V
3 x 2,5 mm²
1N AC 230 V
3 x 2,5 mm²
60 Hz
3 x 20 A
Type B
8,2 kW
50/60 Hz
1 x 25 A
Type B
5,5 kW
50 Hz
1 x 25 A
Type B
5,5 kW
60 Hz
1 x 25 A
Type B
5,5 kW