Technical Information
4.7
Intermediate Plate Assembly Removal
The intermediate plate must be removed to replace the capsule magazine
optical sensor (N3) and the waste container optical sensors (N1 and N2).
1. Remove the appliance for service; see Section 010-4.1.
2. Remove the left and right side panels.
3. Remove the rear panel.
4. Remove the top casing (Section 010-4.5).
5. Remove the front casing (Section 010-4.6).
6. Remove the carrier panel (Section 030-4.2).
7. Remove the brew unit; see Section 050-4.1.
8. Remove the ceramic valve; see Section 050-4.3.
9. Remove the steam valve; see Section 050-4.4.
10. Remove the capsule magazine motor; see Section 050-4.5.
11. Remove the capsule transport motor; see Section 050-4.6.
12. Remove the intermediate plate retaining screws.
13. Adjust wiring and hoses as necessary and lift the intermediate plate from
the appliance.
N1
Figure 050-10: Intermediate Plate Assembly
Note:
Use caution when lifting and removing the intermediate plate, as wiring to
N3 is still connected and fastened to the underside of the assembly.
N2
58
CVA 265x & CVA 266x
N3