Technical Information
3.2
Fault Code Summary
Fault
Code
F 1
F 2
F 3
F 4
F 10
F 17
F 42
F 45
F 47
F 71
F 72
F 73
F 74
F 75
F 76
F 77
F 80
F 81
F 82
F 83
Table 060-3: Fault Code Summary
3.3
Fault Code F1
Cause:
Coffee/hot-water NTC short-circuited.
Remedy:
Check/replace the coffee/hot-water NTC.
Coffee/hot-water NTC temperature sensor short-circuited
Coffee/hot-water NTC temperature sensor open-circuited
Steam NTC temperature sensor short-circuited
Steam NTC temperature sensor open-circuited
No water intake
Water tank not installed
Hose/connections blocked or crimped
Water tank valve jammed/blocked
Inoperative flow meter
Inoperative coffee/hot-water pump
Hoses on ceramic valve have been swapped (connected in reverse)
Insufficient water intake
Water tank not installed or not installed correctly
Hose/connections blocked or crimped
Water tank valve jammed/blocked
Inoperative flow meter
Inoperative coffee/hot-water pump
Hoses on ceramic valve have been swapped (connected in reverse)
Main power frequency not registered
Electronic fault
Communication fault between electronics
Capsule magazine jammed
Inoperative capsule magazine motor
Inoperative capsule magazine motor switch
Capsule transport jammed
Inoperative capsule transport motor
Inoperative capsule magazine switch
Brew unit jammed
Inoperative brew unit motor
Inoperative brew unit position switch
Inoperative ceramic valve motor
Inoperative ceramic valve position switch
Capsule not ejected from brew unit
Capsule jammed during pressing
Faulty initiation of ceramic valve
Inoperative ceramic valve switch
Coffee/hot-water heater not heating
Steam heater not heating
Coffee/hot-water heater overheating
Steam heater overheating
Cause
64
CVA 265x & CVA 266x
See Section
060-3.3
060-3.4
060-3.6
060-3.6
060-3.7
060-3.8
060-3.9
060-3.10
060-3.11
060-3.12
060-3.13
060-3.14
060-3.15
060-3.16
060-3.17
060-3.18
060-3.19
060-3.20
060-3.22
060-3.23