Operating and Installation Instructions Ventilation System To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 11 467 740...
Contents IMPORTANT SAFETY INSTRUCTIONS .............. 3 Caring for the environment ................ 11 Guide to the appliance .................. 12 Description of functions .................. 14 Operation...................... 15 Turning on the blower.................... 15 Selecting the power level ..................15 Delayed shut-down ....................15 Turning off the blower....................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
Page 4
Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician. A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
Page 5
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met.
Page 6
IMPORTANT SAFETY INSTRUCTIONS Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer. If the power cord is damaged, it must only be replaced by a qualified service technician.
Page 7
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS.
Page 8
IMPORTANT SAFETY INSTRUCTIONS Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat. Similarly, never leave an open flame unattended when grilling. ...
Page 9
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Page 10
Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void.
Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
Page 13
Overhead lighting c OdorFree charcoal filters (2 filters) Optional accessories for recirculation mode d Grease filters (DA 2360: 1 filter; DA 2390: 2 filters) e Controls f On/Off button for the blower g Buttons for setting the blower power...
Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the Recirculation mode hoods require a model: recirculation kit and OdorFree Charcoal Filters (available as optional Extraction mode accessories), see “Technical Data” for more information. The air is drawn in and cleaned by the grease filters and directed outside.
Operation Turning on the blower Turning off the blower Press the On/Off control to turn Switch the blower on as soon as you start cooking. This is to ensure that the blower off. vapors are captured right from the start. The ...
Operation Turning power management on/off Safety shut-off You can deactivate power If power management has been management. deactivated, the ventilation hood will Keep in mind that this may increase switch itself off automatically after energy consumption. 12 hours if it has been left on (blower and overhead lighting).
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
Cleaning and care Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapors, preventing soiling of the ventilation hood. The grease filters must be cleaned at regular intervals. Heavily soiled grease filters hinder air extraction and will lead to increased levels of soiling in the ventilation hood ...
Use a commonly available household OdorFree Charcoal Filter dishwashing detergent. With recirculation mode, two charcoal In a Miele dishwasher use the filters must be installed in addition to “Normal” program. the grease filters. These are designed to absorb cooking odors.
The light bulbs should be replaced with the following: Bulb type ......LED, GU10 Power ..........3W Light bulbs are available from Miele or specialist dealers. Fit the charcoal filters into the frame. Press the filters into the holders.
Page 22
Cleaning and care Turn off the blower and the lighting. The light bulbs can get very hot when in use. Allow the bulbs to cool down for a few minutes before changing them. Disconnect the hood from the electrical supply before replacing the light bulbs (see “IMPORTANT SAFETY INSTRUCTIONS”).
Contracts offered by other providers for For further information, please refer to Miele products will not be recognized your warranty booklet. by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
*INSTALLATION* Installation Before installation Installation materials Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter. The ventilation hood is intended for installation in wall cabinets, ventilation housing units, vent flues or above kitchen islands.
Page 25
*INSTALLATION* Installation Keep the following in a safe place: Installation plan See the installation plan for details of the individual steps involved in the installation of this appliance. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
*INSTALLATION* Installation Appliance dimensions The drawing is not to scale...
Page 27
1" (25 mm) from the cut-out. c Alternatively, the ventilation hood can be secured to four fixing points on an interim shelf. d There are additional fixing points on the installation surface. Installation dimensions will differ if you are using the Miele DAA 6 adapter...
Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
*INSTALLATION* Installation Installation recommendations – Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. – To achieve optimum vapor extraction, the ventilation system must be centered over the cooktop, not to the side or behind.
*INSTALLATION* Installation Uneven installation surfaces If the installation surface is uneven making flush installation difficult, the frame can be realigned. Fit the ventilation system as described on the installation plan. Fit one of the screws supplied into Disconnect the ventilation system each bulb holder.
*INSTALLATION* Installation – The exhaust ducting must not be Air venting kinked or compressed. WARNING: Danger of toxic fumes. – Ensure that all connections are Gas cooking appliances release strong and airtight. carbon monoxide that can be harmful or fatal if inhaled. Remember that any restriction of the To reduce the risk of fire and to air flow rate will reduce extraction...
*INSTALLATION* Installation Condensate trap Reducing Collar (optional accessory) If you would like to reduce the In addition to insulating the exhaust environmental impact of your ventilation duct, we recommend installing a system by limiting the CFM output the condensate trap to collect and Reducing Collar can be installed.
CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
Technical data Blower motor 350 W Overhead lighting DA 2360 2 x 3 W DA 2390 4 x 3 W Total connected load DA 2360 356 W DA 2390 362 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Power cord length 2.5 ft (0.75 m) Weight DA 2360 24.2 lbs (11 kg) DA 2390 28.6 lbs (13 kg)
Page 35
Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive Phone: 800-843-7231 Vaughan, ON L4K 4V8 609-419-4298 Fax: www.miele.ca www.mieleusa.com...
Page 36
DA 2360 DA 2390 en-US M.-Nr. 11 467 740 / 01...