hit counter code
Miele DA2360SS Operating And Installation Instructions
Miele DA2360SS Operating And Installation Instructions

Miele DA2360SS Operating And Installation Instructions

Ventilation system

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 254 380

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA2360SS

  • Page 1 Operating and Installation Instructions Ventilation System To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 254 380...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS ............Caring for the environment ................11 Guide to the ventilation hood ................12 Description of functions ................... 14 Operation......................15 Turning on the blower..................15 Selecting the power level ..................15 Delayed shut-down ..................... 15 Turning off the blower..................
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 4  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS  Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS  During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: - The circuit breakers on the electrical service panel are tripped. - The screw-type fuses on the electrical service panel have been removed.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS - a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. - b) NEVER PICK UP A FLAMING PAN - You may be burned.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place.  Please note that the heat rising from the stovetop during cooking can cause the ventilation hood to become very hot.
  • Page 9  When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Always observe local building code requirements when selecting duct material.  Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer.
  • Page 11: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 12: Guide To The Ventilation Hood

    Guide to the ventilation hood...
  • Page 13 Guide to the ventilation hood a Vent collar Extraction ducting can be directed through the back of the ventilation hood or upward to the ceiling. b Overhead lighting c Charcoal filters Optional accessories for recirculation mode d Grease filter DA 2360: x 1, DA 2390: x 2 e Controls f Control for switching the blower on and off...
  • Page 14: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the Recirculation mode hoods require a model: recirculation kit and OdorFree Charcoal Filters (available as optional Extraction mode accessories), see “Technical Data” for more information. The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 15: Operation

    Operation Turning on the blower Turning off the blower  Press the On/Off control  to turn Switch the blower on as soon as you start cooking. This is to ensure that the blower off. vapors are captured right from the start. The ...
  • Page 16: Turning Power Management On/Off

    Operation Turning power management on/off Safety shut-off You can deactivate power If power management has been management. deactivated, the ventilation hood will Keep in mind that this may increase switch itself off automatically after energy consumption. 12 hours if it has been left on (blower and overhead lighting).
  • Page 17: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 18: Cleaning And Care

    Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
  • Page 19: Grease Filters

    Cleaning and care Grease filters The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.) from the kitchen vapors, preventing soiling of the ventilation hood. The grease filters must be cleaned at regular intervals. Heavily soiled grease filters hinder air extraction and will lead to increased levels of soiling in the ventilation hood ...
  • Page 20: Replacing The Grease Filter

    Doing so will prevent a fire Charcoal filters are available to order via hazard. the Miele Web Store (see end of this  Reinstall the grease filters. When booklet for contact details), or from inserting the filters, make sure that your Miele dealer.
  • Page 21: Disposing Of Charcoal Filters

    Cleaning and care  Fit the charcoal filters into the frame.  Press the filters into the holders.  Reinstall the grease filters. When to change the OdorFree Charcoal Filter Replace the charcoal filters when they no longer absorb kitchen odors effectively, and at least every 6 months.
  • Page 22: Changing A Light Bulb

    (see “IMPORTANT Bulb type ......LED, GU10 SAFETY INSTRUCTIONS”). Power ..........3W Light bulbs are available from Miele or specialist dealers.  Insert the lever supplied into the gap between the bulb and the bulb holder..
  • Page 23: Customer Service

    In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 24: Installation

    *INSTALLATION* Installation Before installation  Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter. The ventilation hood is intended for installation in wall cabinets, ventilation 4 M5 x 40 mm screws, 4 washers, housing units, vent flues or above 4 M5 nuts for securing the ventilation kitchen islands.
  • Page 25 *INSTALLATION* Installation Keep the following in a safe place: Installation plan See the installation plan for details of the individual steps involved in the installation of this appliance. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 26: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions The drawing is not to scale...
  • Page 27 1" (25 mm) from the cut-out. c Alternatively, the ventilation hood can be secured to four fixing points on an interim shelf. d There are additional fixing points on the installation surface. Installation dimensions will differ if you are using the Miele DAA 6 adapter...
  • Page 28: Distance Between Cooktop And Ventilation Hood (S)

    Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 29: Installation Recommendations

    *INSTALLATION* Installation Installation recommendations - Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. - To achieve optimum vapor extraction, the ventilation system must be centered over the cooktop, not to the side or behind.
  • Page 30: Uneven Installation Surfaces

    *INSTALLATION* Installation Uneven installation surfaces If the installation surface is uneven making flush installation difficult, the frame can be realigned.  Fit the ventilation system as described on the installation plan.  Fit one of the screws supplied into  Disconnect the ventilation system each bulb holder.
  • Page 31: Air Venting

    “Appliance dimensions”). This applies in particular when using flat ducting. If the exhaust is ducted through an outside wall, a Miele wall vent or roof - The ducting should be as short and vent (available as an optional straight as possible.
  • Page 32: Condensate

    The arrow on the casing indicates exhaust socket of the fan. the direction of airflow. Condensate Miele will not accept warranty claims If the ducting is to run through cool for any functional defects or damage rooms or ceiling space, for example, the caused by inadequate ducting.
  • Page 33: Electrical Connection

    CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 34: Technical Data

    Technical data Blower motor 350 W Overhead lighting DA 2360 2 x 3 W DA 2390 4 x 3 W Total connected load DA 2360 356 W DA 2390 362 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Power cord length 2.5 ft (0.75 m) Weight DA 2360 24.2 lbs (11 kg) DA 2390 28.6 lbs (13 kg) Optional accessories for recirculation mode DUU 150 or DUU 151 conversion kit and DKF 19-900 charcoal filter set.
  • Page 35 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...