Technical data
PDW 909 machine data
Electrical connection
Supply voltage
Frequency
Power rating
Current consumption
Fuse rating
Heater rating
Installation dimensions
Casing width (without add-on components)
Casing height (without add-on components)
Casing depth (without add-on components)
Overall machine width
Overall machine height
Overall machine depth
Minimum width of transport opening
Minimum safety distance between wall and back of machine
Diameter of door opening
Door opening angle
Weight and floor load
Net weight
Max. floor load in operation
Plumbing
Cold water connection
Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose included in scope of supply
Hot water connection
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied
Drainage (DP)
Maximum waste water temperature
Drain connection (on machine)
Maximum drainage rate
130
See data plate
See data plate
See data plate
See data plate
See data plate
See data plate
692 mm
1940 mm
761 mm
692 mm
1942 mm
851 mm
800 mm
400 mm
370 mm
180°
see installation plan
see installation plan
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4 "
2000 mm
60 °C
100 - 1000 kPa (1 - 10 bar)
10 l/min
3/4 "
2000 mm
95 °C
External diameter 22 (DN 22)
26 l/min