Galaxy Dimension Installer Manual
Option 53 – Program Outputs
This option is used by the engineer to modify the programming of the outputs on the system. The option also
allows the attributes of the outputs to be changed. The programmable options are:
Attributes
1
Output Function
2
Output Mode
3
Output Polarity
4
Diag. Recording
5
Descriptor
6
Lighting
7
Output Groups
Note: Groups only appear if the Group option is enabled
(refer to option 63.1 = OPTIONS. Groups).
Selecting Outputs
RIO Outputs
On entering the option, the first output on the system is displayed; the output address, function and mode are
displayed on the top line, the polarity and assigned groups are displayed on the bottom line.
From the display of the first output, any output on the system can be displayed by pressing the A or B keys or
by entering the address of a specific output.
The output is selected for programming by pressing the ent key; the first output programming attribute 1=Op
Function is displayed.
Trigger Header Outputs
There are six trigger outputs, that can be used as communication triggers, but can also be used for any other
purpose. The output address and default function of these outputs are as follows:
0001 - Fire
0002 - Panic
0003 - Intruder
0004 - Set
0005 - Zone Omit
0006 - Confirm
Description
Assign output type
1 = Latch - requires valid code to reset
2 = Reflex - follows activation status of zones
3 = Pulse (001 - 3000 secs) - activates for programmed period
0 = POS - 12V going to 0V in activation
1 = NEG - 0V going to 12V in activation
Assigns output to be active during Diagnostic Test
Assigs a descriptor of up to 12 characters for each output
1 = Control (0=OFF, 1=Toggle, 2=Trigger)
2 = Show Status (0=OFF, 1=ON)
Assign groups to the output
Table 6-18. Output Attributes