Tumble dryer supervisor level
External exhaust
flap
Additional fan
Pressure sensor
Peak load signal
Peak load preven-
tion
120
External applications
External hardware is connected via the Miele Connector Box.
The time delay between the external exhaust-air flap's activation
point and the switch-on time for the drum/fan motor is regulated.
A message appears in the display while the exhaust air flap is open.
- Factory default: off
This option must always be selected if there is no exhaust air flap to
activate. This prevents the program from being canceled.
- On (1 second to 5 minutes)
External hardware is connected via the Miele Connector Box.
The additional fan is switched on by the dryer (via Connector Box) in
parallel with the internal fan.
- Off
- On
External hardware is connected via the Miele Connector Box.
When using a shared exhaust air duct, one tumble dryer may have to
be switched off or suppressed from the outset if certain pressure lev-
els have built up in the ducting. The external pressure sensor is only
checked if the external exhaust air flap and/or the external additional
fan is set to "on".
A message appears in the display while the exhaust-air flap is open.
- Off = Not active
-
= Active
NO contact
Responds to high potential
-
= Active
NC contact
Responds to low potential
External hardware is connected via the Miele Connector Box.
The peak-load negotiation function enables the tumble dryer to be
connected to an energy management system. When a signal is regis-
tered, the tumble dryer's heater is switched off for a short period or
the machine is prevented from being switched on.
A peak-load signal can be issued via the Connector Box or via the
COM module.
- Factory default:
No function
-
Peak load with 230V
-
Peak load with 0V
-
KOM module
With this function, the application of a hygiene program is not
amended when a peak-load signal is in place. The heater stays
switched on.
- Factory default:
Off