Miele PDW 909 Operating And Installation Instructions page 93

Commercial washer-dryer stack
Hide thumbs Also See for PDW 909:

Advertisement

Drain pump (de-
pending on model)
Special regula-
tions for Austria
In machines with drain pump, the suds are drained through a drain
pump with a delivery head of max. 3.3 ft (1 m).
The drain hose must be installed free of kinks for the suds to drain
freely.
There are the following options for draining the machine:
- drain hose connected to a plastic drain pipe with a rubber sleeve
(there is no need to use a siphon)
- drain hose connected securely to a sink with a plastic nipple
- connected securely to a floor drain (gully)
If required, the hose can be extended to a length of up to 16.4 ft (5 m).
For a drain height of more than 3' 3" (1 m), a replacement drain pump
for a delivery head of max. 6 ft (1.8 m) is may be needed.
The washing machine can be connected directly to the drain pipe if
the sewer system meets the requirements of Austrian standard
ÖNORM 2501.
Electrical connection
The electrical connection must only be carried out by a suitably quali-
fied electrician in accordance with local and national regulations.
A residual current device (RCD) type B (sensitive to universal cur-
rent) must be used if one is being installed.
The electrical components of the machine comply with EN 60335-1,
EN 50571.
The voltage is stated on the data plate.
For hard-wired machines, an all-pole means of deactivation must be
provided on site. Switches with a minimum contact gap greater than
3 mm are suitable disconnection switches. These include C/Bs, fuses,
and contactors (VDE 0660).
The plug connections or disconnection switches must be accessible
at all times.
If the machine is disconnected from the power supply, the disconnec-
tion switches must be lockable or the points of disconnection must be
monitored at all times.
 Preventing hazards
If one of the power cords for this machine is damaged, it must be
replaced by the manufacturer, Customer Service, or a similarly qual-
ified person.
Please check the enclosed wiring diagram.
Supply air and exhaust air management
The tumble dryer may only be operated when the ducting has been
connected properly and the room is sufficiently ventilated.
Installation
93